Home › Engine / Hybrid System › 1VD-FTV (STARTING) › STARTER › from 2015.08
RM2660E _51 Engine / Hybrid System _052803 1VD-FTV STARTING _0255243 STARTER G

1VD-FTV STARTING  STARTER  INSPECTION  


PROCEDURE

Hide 28100 1.INSPECT STARTER ASSEMBLY

A175307E01
4.604,0.192 5.394,0.357 0.790,0.165 10 Terminal 50 5.316,1.077 6.106,1.242 0.790,0.165 10 Terminal 30 1.483,2.249 2.213,2.413 0.730,0.165 10 Terminal C 3.731,0.7 4.479,0.266 false 4.478,0.265 4.571,0.265 false 3.799,1.043 2.397,2.317 false 2.401,2.314 2.214,2.314 false 4.17,0.86 5.111,1.155 false 5.111,1.155 5.297,1.155 false

CAUTION:

As a large electric current passes through the cable during this inspection, a thick cable must be used. If not, the cable may become hot and cause injury.


NOTICE:

The following tests must be done within 3 to 5 seconds to prevent the coil from burning out.


a.

Perform the operation test without load.

A175308

i.

Grip the starter in a vise.


ii.

Connect the battery and an ammeter to the starter with terminal 30 disconnected.

NOTICE:

Do not connect terminal 30 to the battery in this step.



iii.

Connect terminal 30 to the battery and check that the starter rotates smoothly and steadily while the pinion gear is moving outward. Then measure the current.

Standard current:

200 A or less at 11 V


If the result is not as specified, repair or replace the starter assembly.



Hide 28160 2.INSPECT STARTER ARMATURE ASSEMBLY

a.
A165485

Inspect the commutator for an open circuit.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Commutator Always Below 1 Ω


If the result is not as specified, replace the armature assembly.



b.
A165486

Inspect the commutator for a short circuit.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Commutator - Armature coil core Always 10 kΩ or higher


If the result is not as specified, replace the armature assembly.



c.
A161636

Using a vernier caliper, measure the commutator diameter.

Standard diameter:

36.0 mm (1.42 in.)


Minimum diameter:

35.0 mm (1.38 in.)


If the diameter is less than the minimum, replace the armature assembly.


d.
A115027

Measure the undercut depth of the commutator.

Standard undercut depth:

0.7 mm (0.0276 in.)


Minimum undercut depth:

0.2 mm (0.00787 in.)


If the undercut depth is less than the minimum, increase the depth using a hacksaw blade.


e.
A154803

Check that the bearing rotates smoothly.

If necessary, replace the starter armature assembly.


f.
A154804

Inspect the commutator circle runout.

i.

Place the commutator on V-blocks.


ii.

Using a dial indicator, measure the circle runout.

Maximum circle runout:

0.05 mm (0.00197 in.)


If the runout is more than the maximum, correct it with sandpaper (#400) or replace the armature assembly.



Hide 28120 3.INSPECT STARTER YOKE ASSEMBLY

a.
A168017

Inspect the field coil for an open circuit.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Terminal C plate - Brushes Always Below 1 Ω


If the result is not as specified, replace the starter yoke assembly.



b.
A168016

Inspect if the field coil is grounded.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Brushes - Starter yoke body Always 10 kΩ or higher


If the result is not as specified, replace the starter yoke assembly.



Hide 4.INSPECT STARTER BRUSH

a.
A161639E02
0.522,1.988 0.990,2.164 0.467,0.176 10 Length 0.053,0.04 1.299,0.216 1.246,0.176 10 Brush Holder Side: 2.049,4.255 2.517,4.419 0.467,0.165 10 Length 1.204,2.53 1.433,2.683 0.229,0.153 0.053,2.345 1.236,2.521 1.183,0.176 10 Starter Yoke Side:

Using a vernier caliper, measure the brush length.

Standard length:

21.0 mm (0.827 in.)


Minimum length:

12.0 mm (0.472 in.)


If the length is less than the minimum, replace the brush holder and starter yoke assembly.


Hide 28140 5.INSPECT STARTER BRUSH HOLDER ASSEMBLY

a.
P021088E09
1.688,0.375 1.844,0.573 0.156,0.198 10 false .

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Positive (+) brush holder - Negative (-) brush holder Always 10 kΩ or higher


If the result is not as specified, replace the brush holder assembly.


b.
ST00019E24
2.354,1.385 3.188,1.708 0.833,0.323 10 false Brush Spring 0.854,1.646 1.26,1.958 0.406,0.313 10 false Brush

Inspect the load of the brush spring.

i.

Take a pull scale reading immediately after the brush spring separates from the brush.

Standard spring installed load:

36 N (3.6 kgf, 8.0 lbf)


Minimum spring installed load:

12 N (1.2 kgf, 2.7 lbf)


If the spring installed load is less than the minimum, replace the brush holder assembly.



Hide 28011 6.INSPECT STARTER CLUTCH SUB-ASSEMBLY

A163083E01
1.807,1.581 2.148,1.734 0.342,0.153 10 Lock 1.99,0.661 2.332,0.813 0.342,0.153 10 Free

a.

Check the starter clutch operation.

i.

Hold the clutch and bearing with one hand and turn the shaft with the other. Check that the inner sleeve turns easily in the "free" direction but cannot turn in the "lock" direction as shown in the illustration.

If the starter clutch sub-assembly does not operate as specified, replace the starter clutch sub-assembly.



Hide 28150 7.INSPECT MAGNET STARTER SWITCH ASSEMBLY

a.
A161641E01
0.285,0.028 1.042,0.188 0.757,0.159 10 Terminal 50 1.225,0.121 1.543,0.252 false 0.191,1.165 0.920,1.325 0.729,0.160 10 Terminal C 1.072,1.248 1.55,0.579 false

Check the pull-in coil for an open circuit.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Terminal 50 - Terminal C Always Below 1 Ω


If the result is not as specified, replace the magnet starter switch assembly.



b.
A161642E01
1.681,0.79 2.451,0.943 0.770,0.153 10 Terminal 50 1.671,0.876 1.029,0.281 false

Check the hold-in coil for an open circuit.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Terminal 50 - Housing Body Always Below 2 Ω


If the result is not as specified, replace the magnet starter switch assembly.