Home › Engine / Hybrid System › CRUISE CONTROL › MILLIMETER WAVE RADAR SENSOR › 2014.08–2015.08
RM2660E _51 Engine / Hybrid System _052804 CRUISE CONTROL _0255253 MILLIMETER WAVE RADAR SENSOR A

CRUISE CONTROL  MILLIMETER WAVE RADAR SENSOR  INSTALLATION  


PROCEDURE

Hide 88211B 1.INSTALL MILLIMETER WAVE RADAR SENSOR ASSEMBLY

a.

Temporarily install the millimeter wave radar sensor assembly with the 3 bolts.


b.
E239944E02
2.417,0.448 2.594,0.646 0.177,0.198 10 true A 2.01,0.167 2.208,0.375 0.198,0.208 10 true B 1.042,1.521 1.229,1.719 0.188,0.198 10 true C

Tighten the 3 bolts in alphabetical order.

Torque:
5.5 N*m (56 kgf*cm, 49 in.*lbf)


c.

Connect the sensor connector.

NOTICE:

Do not use a sensor which has been dropped or subjected to any strong shocks.



Hide 53292A 3.INSTALL UPPER RADIATOR SUPPORT SEAL

Hide 88211B 4.ADJUST MILLIMETER WAVE RADAR SENSOR ASSEMBLY