Home › Drivetrain › AB60F (AUTOMATIC TRANSMISSION / TRANSAXLE) › AUTOMATIC TRANSMISSION SYSTEM (for 1VD-FTV) › 2014.08–2015.08
RM2660E _52 Drivetrain _052805 AB60F AUTOMATIC TRANSMISSION / TRANSAXLE _0255265 AUTOMATIC TRANSMISSION SYSTEM(for 1VD-FTV) C

AB60F AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM(for 1VD-FTV)  P0722  Output Speed Sensor Circuit No Signal  


DESCRIPTION

The speed sensor SP2 detects the rotation speed of the transmission output shaft and sends signals to the ECM. The ECM determines the vehicle speed based on these signals. An AC voltage is generated in the speed sensor SP2 coil as the parking gear mounted on the rear planetary gear assembly rotates, and this voltage is sent to the ECM. The parking gear on the rear planetary gear is used as the timing rotor for this sensor.

The gear shift point and lock-up timing are controlled by the ECM based on the signals from this vehicle speed sensor and the throttle position sensor signal.

DTC Code DTC Detection Condition Trouble Area
P0722 All the conditions below are detected 500 times or more continuously (2 trip detection logic).
(a) No signal from the speed sensor SP2 is input to the ECM while 4 pulses of the No. 1 vehicle speed sensor signal are sent.
(b) The vehicle speed is 9 km/h (6 mph) or more for at least 5 sec.
(c) The park/neutral position switch is off.
(d) The transfer position is not in neutral.
·

Open or short in speed sensor SP2 circuit

·

Speed sensor SP2

·

ECM

·

Automatic transmission (clutch, brake or gear, etc.)



Reference: Inspect using an oscilloscope.

Check the waveform of the ECM connector.

Standard:
for LHD
Terminal No. (Symbol) Tool Setting Condition Specified Condition
C45-68 (SP2+) - C45-67 (SP2-) 2 V/DIV., 2 msec./DIV Vehicle speed 20 km/h (12 mph) Refer to illustration

for RHD
Terminal No. (Symbol) Tool Setting Condition Specified Condition
C46-68 (SP2+) - C46-67 (SP2-) 2 V/DIV., 2 msec./DIV Vehicle speed 20 km/h (12 mph) Refer to illustration


C175013E01
2.45,0.858 3.105,1.059 0.656,0.201 10 2 V/DIV. 2.589,1.575 3.001,1.777 0.411,0.202 10 GND 1.313,2.598 2.269,2.786 0.956,0.188 10 2 msec./DIV.

MONITOR DESCRIPTION

The output speed sensor SP2 monitors the output shaft speed. The ECM controls the gear shift point and the lock up timing based on the signals from the output speed sensor SP2 and throttle position sensor.

If the ECM detects no signal from the output speed sensor SP2 even while the vehicle is moving, it will conclude that there is a malfunction of the output speed sensor SP2. The ECM will illuminate the MIL and store a DTC.

WIRING DIAGRAM

C155187E24
5.642,1.051 6.204,1.252 0.561,0.202 10 SP2+ 5.642,2.183 6.204,2.385 0.561,0.202 10 SP2- 5.367,1.177 5.580,1.378 0.213,0.202 10 68 0.615,2.479 1.940,2.681 1.325,0.202 10 Speed Sensor SP2 5.367,2.309 5.580,2.511 0.213,0.202 10 67 0.615,2.293 0.947,2.495 0.332,0.202 10 C36 1.285,1.191 1.447,1.393 0.162,0.202 10 2 1.285,2.04 1.447,2.242 0.162,0.202 10 1 0.044,2.887 0.835,3.089 0.791,0.202 10 *1: for LHD 0.044,3.261 0.835,3.463 0.791,0.202 10 *2: for RHD 5.793,3.13 6.255,3.300 0.461,0.170 10 C46*2 5.793,2.977 6.255,3.146 0.461,0.170 10 C45*1 5.793,3.285 6.215,3.480 0.422,0.195 10 ECM

CAUTION / NOTICE / HINT

DATA LIST


HINT:

Using the intelligent tester to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


a.

Warm up the engine.


b.

Turn the ignition switch off.


c.

Connect the intelligent tester to the DLC3.


d.

Turn the ignition switch to ON.


e.

Turn the intelligent tester on.


f.

Enter the following menus: Powertrain / ECT / Data List.


g.

According to the display on the tester, read the Data List.

ECT
Tester Display Measurement Item/Range Normal Condition Diagnostic Note
SPD (SP2) Output shaft speed/
Min.: 0 km/h (0 mph)
Max.: 255 km/h (158 mph)
Vehicle stopped: 0 km/h (0 mph) (output shaft speed equal to vehicle speed) -

HINT:
·

SPD (SP2) is always 0 while driving:

Open or short in the sensor or circuit.

·

The SPD (SP2) value displayed on the tester is much lower than the actual vehicle speed:

Sensor trouble, improper installation, or intermittent connection trouble of the circuit.





PROCEDURE

1.INSPECT SPEED SENSOR SP2 INSTALLATION
a.
C159067E01
2.267,2.623 2.976,2.824 0.710,0.202 10 Clearance 0.341,0.443 1.166,0.645 0.825,0.202 10 CORRECT 2.186,0.443 3.205,0.645 1.020,0.202 10 INCORRECT

Check the speed sensor SP2 installation.

OK:

The installation bolt is tightened properly and there is no clearance between the sensor and transmission case.




OK

2.INSPECT SPEED SENSOR SP2

NG

SECURELY INSTALL OR REPLACE SPEED SENSOR SP2

2.INSPECT SPEED SENSOR SP2
a.
C159420E02
0.058,0.005 2.640,0.372 2.582,0.367 10 Component without harness connected: (Speed Sensor SP2) 1.346,2.308 1.577,1.709 false 2.107,2.308 1.877,1.709 false 1.248,2.309 1.426,2.511 0.178,0.202 10 2 2.096,2.309 2.246,2.511 0.150,0.202 10 1

Disconnect the speed sensor connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 560 to 680 Ω




OK

3.CHECK HARNESS AND CONNECTOR (SPEED SENSOR SP2 - ECM)

NG

3.CHECK HARNESS AND CONNECTOR (SPEED SENSOR SP2 - ECM)
a.
U164868E01
0.054,0.005 2.463,0.372 2.408,0.367 10 Front view of wire harness connector: (to ECM) 1.005,3.206 1.756,3.408 0.751,0.202 10 68 (SP2+) 0.33,3.191 0.756,2.414 false 0.055,3.206 0.714,3.408 0.659,0.202 10 67 (SP2-) 1.263,3.191 0.837,2.414 false 1.564,1.38 1.939,1.613 0.375,0.233 10 C46 1.564,1.07 1.939,1.303 0.375,0.233 10 C45 1.974,1.38 2.174,1.582 0.200,0.202 10 *2 1.974,1.07 2.174,1.272 0.200,0.202 10 *1 0.055,3.692 0.846,3.894 0.791,0.202 10 *1: for LHD 0.055,4.15 0.846,4.352 0.791,0.202 10 *2: for RHD

Disconnect the ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
for LHD
Tester Connection Condition Specified Condition
C45-68 (SP2+) - C45-67 (SP2-) 20°C (68°F) 560 to 680 Ω
C45-68 (SP2+) - Body ground Always 10 kΩ or higher
C45-67 (SP2-) - Body ground Always 10 kΩ or higher

for RHD
Tester Connection Condition Specified Condition
C46-68 (SP2+) - C46-67 (SP2-) 20°C (68°F) 560 to 680 Ω
C46-68 (SP2+) - Body ground Always 10 kΩ or higher
C46-67 (SP2-) - Body ground Always 10 kΩ or higher




OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR