Home › Drivetrain › AB60F (AUTOMATIC TRANSMISSION / TRANSAXLE) › TRANSMISSION WIRE
RM2660E _52 Drivetrain _052805 AB60F AUTOMATIC TRANSMISSION / TRANSAXLE _0255269 TRANSMISSION WIRE G

AB60F AUTOMATIC TRANSMISSION / TRANSAXLE  TRANSMISSION WIRE  INSPECTION  


PROCEDURE

Hide 82125J 1.INSPECT TRANSMISSION WIRE (ATF TEMPERATURE SENSOR)

C159421E77
2.135,1.979 2.458,2.292 false 2,1.99 1.906,2.302 false 2.219,1.656 2.573,1.198 false 2.094,1.667 2,1.208 false 2.375,2.323 2.813,2.51 0.438,0.188 10 false OT+ 1.688,2.323 2.125,2.51 0.438,0.188 10 false OT2+ 0.094,0.063 2.583,0.448 2.49,0.385 10 false Component without harness connected: (No. 1 Transmission Wire) 2.531,0.948 2.969,1.135 0.438,0.188 10 false OT- 1.813,0.969 2.25,1.156 0.438,0.188 10 false OT2-

a.

Measure the resistance according to the value(s) in the table below.

HINT:

If the resistance is out of the specified range at any of the ATF temperatures shown in the table below, the driveability of the vehicle may decrease.


Standard Resistance:
Tester Connection ATF Temperature Specified Condition
1 (OT-) - 9 (OT+) 10°C (50°F) 5 to 8 kΩ
1 (OT-) - 9 (OT+) 25°C (77°F) 2.5 to 4.5 kΩ
1 (OT-) - 9 (OT+) 110°C (230°F) 0.22 to 0.28 kΩ
2 (OT2-) - 10 (OT2+) 10°C (50°F) 5 to 8 kΩ
2 (OT2-) - 10 (OT2+) 25°C (77°F) 2.5 to 4.5 kΩ
2 (OT2-) - 10 (OT2+) 110°C (230°F) 0.22 to 0.28 kΩ


If the result is not as specified, replace the transmission wire.