Home › Drivetrain › AB60F (AUTOMATIC TRANSMISSION / TRANSAXLE) › VALVE BODY ASSEMBLY
RM2660E _52 Drivetrain _052805 AB60F AUTOMATIC TRANSMISSION / TRANSAXLE _0255270 VALVE BODY ASSEMBLY G

AB60F AUTOMATIC TRANSMISSION / TRANSAXLE  VALVE BODY ASSEMBLY  INSPECTION  


PROCEDURE

Hide 1.INSPECT SHIFT SOLENOID VALVE SL1

C358507E01
1.104,3.021 1.552,3.292 false 1.844,1.198 2.292,0.896 false 1.854,3.323 2.344,2.938 false 1.104,0.917 1.552,1.188 false 0.229,0.042 2.677,0.385 2.448,0.344 10 false Component without harness connected: (Shift Solenoid Valve SL1) 0.969,0.792 1.125,0.99 0.156,0.198 10 false 2 2.344,0.792 2.5,0.99 0.156,0.198 10 false 1 0.969,2.844 1.125,3.042 0.156,0.198 10 false 2 2.406,2.813 2.563,3.01 0.156,0.198 10 false 1 1.219,4.323 1.417,4.521 0.198,0.198 10 false (-) 2.031,4.323 2.229,4.521 0.198,0.198 10 false (+)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



b.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) with a 21 W bulb → Shift solenoid valve Terminal 1

·

Battery negative (-) → Terminal 2


Valve moves and makes an operating noise


If the result is not as specified, replace the solenoid valve.


Hide 2.INSPECT SHIFT SOLENOID VALVE S1

C160563E01
1.71,0.819 1.941,1.002 0.231,0.184 10 (-) 0.056,0 1.633,0.186 1.577,0.186 10 Shift Solenoid Valve S1: 2.477,0.819 2.709,1.002 0.231,0.184 10 (+)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Shift solenoid valve S1 connector terminal - Shift solenoid valve S1 body 20°C (68°F) 11 to 15 Ω



b.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) → Shift solenoid valve S1 connector

·

Battery negative (-) → Shift solenoid valve S1 body


Valve moves and makes an operating noise


If the result is not as specified, replace the solenoid valve.


Hide 3.INSPECT SHIFT SOLENOID VALVE S2

C160564E01
2.349,0.818 2.580,1.001 0.231,0.184 10 (+) 0.056,0 1.633,0.186 1.577,0.186 10 Shift Solenoid Valve S2: 3.116,0.818 3.347,1.001 0.231,0.184 10 (-)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Shift solenoid valve S2 connector terminal - Shift solenoid valve S2 body 20°C (68°F) 11 to 15 Ω



b.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) → Shift solenoid valve S2 connector

·

Battery negative (-) → Shift solenoid valve S2 body


Valve moves and makes an operating noise


If the result is not as specified, replace the solenoid valve.


Hide 4.INSPECT SHIFT SOLENOID VALVE S3

C160563E02
1.71,0.819 1.941,1.002 0.231,0.184 10 (-) 0.056,0 1.633,0.186 1.577,0.186 10 Shift Solenoid Valve S3: 2.477,0.819 2.709,1.002 0.231,0.184 10 (+)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Shift solenoid valve S3 connector terminal - Shift solenoid valve S3 body 20°C (68°F) 11 to 15 Ω



b.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) → Shift solenoid valve S3 connector

·

Battery negative (-) → Shift solenoid valve S3 body


Valve moves and makes an operating noise


If the result is not as specified, replace the solenoid valve.


Hide 5.INSPECT SHIFT SOLENOID VALVE S4

C123198E03
1.644,0.82 1.876,1.003 0.231,0.184 10 (-) 0.055,0 1.632,0.186 1.577,0.186 10 Shift Solenoid Valve S4: 2.412,0.82 2.643,1.003 0.231,0.184 10 (+)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Shift solenoid valve S4 connector terminal - Shift solenoid valve S4 body 20°C (68°F) 11 to 15 Ω



b.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) → Shift solenoid valve S4 connector

·

Battery negative (-) → Shift solenoid valve S4 body


Valve moves and makes an operating noise


If the result is not as specified, replace the solenoid valve.


Hide 6.INSPECT SHIFT SOLENOID VALVE SL2

C358507E02
1.104,3.021 1.552,3.292 false 1.844,1.198 2.292,0.896 false 1.854,3.323 2.344,2.938 false 1.104,0.917 1.552,1.188 false 0.229,0.042 2.677,0.385 2.448,0.344 10 false Component without harness connected: (Shift Solenoid Valve SL2) 0.969,0.792 1.125,0.99 0.156,0.198 10 false 2 2.344,0.792 2.5,0.99 0.156,0.198 10 false 1 0.969,2.844 1.125,3.042 0.156,0.198 10 false 2 2.406,2.813 2.563,3.01 0.156,0.198 10 false 1 1.219,4.323 1.417,4.521 0.198,0.198 10 false (-) 2.031,4.323 2.229,4.521 0.198,0.198 10 false (+)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



b.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) with a 21 W bulb → Shift solenoid valve Terminal 1

·

Battery negative (-) → Terminal 2


Valve moves and makes an operating noise


If the result is not as specified, replace the solenoid valve.


Hide 7.INSPECT SHIFT SOLENOID VALVE SR

C160565E01
2.349,0.818 2.580,1.002 0.231,0.184 10 (+) 0.056,0 1.633,0.186 1.577,0.186 10 Shift Solenoid Valve SR: 3.116,0.818 3.347,1.002 0.231,0.184 10 (-)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Shift solenoid valve SR connector terminal - Shift solenoid valve SR body 20°C (68°F) 11 to 15 Ω



b.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) → Shift solenoid valve SR connector

·

Battery negative (-) → Shift solenoid valve SR body


Valve moves and makes an operating noise


If the result is not as specified, replace the solenoid valve.


Hide 8.INSPECT SHIFT SOLENOID VALVE SLT

C358531E01
1.875,1.208 2.344,0.844 false 1.594,1.229 1.073,0.813 false 1.865,3.344 2.333,2.979 false 1.583,3.344 1.063,2.927 false 0.104,0.042 2.573,0.417 2.469,0.375 10 false Component without harness connected: (Shift Solenoid Valve SLT) 2.406,0.688 2.563,0.885 0.156,0.198 10 false 1 0.948,0.667 1.104,0.865 0.156,0.198 10 false 2 2.375,2.833 2.531,3.031 0.156,0.198 10 false 1 0.906,2.792 1.063,2.99 0.156,0.198 10 false 2 1.271,4.344 1.479,4.542 0.208,0.198 10 false (+) 2.01,4.333 2.219,4.531 0.208,0.198 10 false (-)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



b.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) with a 21 W bulb → Shift solenoid valve Terminal 2

·

Battery negative (-) → Terminal 1


Valve moves and makes an operating noise


If the result is not as specified, replace the solenoid valve.


Hide 9.INSPECT SHIFT SOLENOID VALVE SLU

C358531E02
1.875,1.208 2.344,0.844 false 1.594,1.229 1.073,0.813 false 1.865,3.344 2.333,2.979 false 1.583,3.344 1.063,2.927 false 0.104,0.042 2.573,0.417 2.469,0.375 10 false Component without harness connected: (Shift Solenoid Valve SLU) 2.406,0.688 2.563,0.885 0.156,0.198 10 false 1 0.948,0.667 1.104,0.865 0.156,0.198 10 false 2 2.375,2.833 2.531,3.031 0.156,0.198 10 false 1 0.906,2.792 1.063,2.99 0.156,0.198 10 false 2 1.271,4.344 1.479,4.542 0.208,0.198 10 false (+) 2.01,4.333 2.219,4.531 0.208,0.198 10 false (-)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



b.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) with a 21 W bulb → Shift solenoid valve Terminal 2

·

Battery negative (-) → Terminal 1


Valve moves and makes an operating noise


If the result is not as specified, replace the solenoid valve.