The ECM memory contains the programs for the normal and power shift patterns and lock-up pattern.
By following the programs corresponding to the signals from the PWR switch (integration control and panel assembly), the park/neutral position switch and other various sensors, the ECM switches the solenoid valves on and off, and controls the transmission gear change and the lock-up clutch operation.
When the PWR switch is pushed, switch contact is made and power mode is selected. To cancel power mode, push the PWR switch once again.
Remove the integration control and panel assembly (See page Drivetrain>AB60F (AUTOMATIC TRANSMISSION / TRANSAXLE)>COMBINATION SWITCH(w/ Entry and Start System)>REMOVAL).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 6 (P) - 5 (E) | PWR switch on | Below 1 Ω |
| 6 (P) - 5 (E) | PWR switch off | 10 kΩ or higher |
| *a | Component without harness connected
(Integration Control and Panel Assembly) |
OK
NG
Disconnect the integration control and panel assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| V9-5 (E) - Body ground | Always | Below 1 Ω |
| *a | Front view of wire harness connector
(to Integration Control and Panel Assembly) |
OK
NG
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A38-51 (PWR) - Body ground | PWR switch on | Below 1 Ω |
| A38-51 (PWR) - Body ground | PWR switch off | 10 kΩ or higher |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A52-51 (PWR) - Body ground | PWR switch on | Below 1 Ω |
| A52-51 (PWR) - Body ground | PWR switch off | 10 kΩ or higher |
| *1 | for LHD |
| *2 | for RHD |
| *a | Front view of wire harness connector
(to ECM) |
OK
NG