Home › Drivetrain › AB60F (AUTOMATIC TRANSMISSION / TRANSAXLE) › AUTOMATIC TRANSMISSION SYSTEM(for 1VD-FTV with DPF) › from 2015.08
RM2660E _52 Drivetrain _052805 AB60F AUTOMATIC TRANSMISSION / TRANSAXLE _0255274 AUTOMATIC TRANSMISSION SYSTEM(for 1VD-FTV with DPF) C

AB60F AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM(for 1VD-FTV with DPF)  P0712  Transmission Fluid Temperature Sensor "A" Circuit Low Input  P0713  Transmission Fluid Temperature Sensor "A" Circuit High Input  


DESCRIPTION

The Automatic Transmission Fluid (ATF) temperature sensor converts the fluid temperature into a resistance value which is input into the ECM.

The ECM applies voltage to the temperature sensor through the ECM terminal THO1.

The sensor resistance changes with the transmission fluid temperature. As the temperature becomes higher, the sensor resistance decreases.

One terminal of the sensor is grounded so that the sensor resistance decreases and the voltage goes down as the temperature becomes higher.

The ECM calculates the fluid temperature based on the voltage signal.

DTC Code DTC Detection Condition Trouble Area
P0712 The No. 1 ATF temperature sensor resistance is below 79 Ω for 0.5 seconds or more (1 trip detection logic).
·

Short in No. 1 ATF temperature sensor circuit

·

No. 1 transmission wire (No. 1 ATF temperature sensor)

·

ECM


P0713 ATF temperature sensor resistance is higher than 156 kΩ for 0.5 sec. or more and either condition is met (1 trip detection logic):
(A) 15 min. or more have elapsed after the engine start when the engine coolant temperature or intake air temperature is -29.375°C (-20.875°F) or less.
(B) 10 sec. or more have elapsed after the engine start when the engine coolant temperature and intake air temperature are higher than -29.375°C (-20.875°F).
·

Open in No. 1 ATF temperature sensor circuit

·

No. 1 transmission wire (No. 1 ATF temperature sensor)

·

ECM



MONITOR DESCRIPTION

These DTCs indicate an open or short in the Automatic Transmission Fluid (ATF) temperature sensor circuit. The ATF temperature sensor converts the ATF temperature to an electrical resistance value. Based on the resistance, the ECM determines the ATF temperature, and the ECM detects an open or short in the ATF temperature circuit. If the resistance value of the ATF temperature is below 79 Ω*1 or higher than 156 kΩ*2, the ECM interprets this as a fault in the ATF sensor or wiring. The ECM will turn on the MIL and store the DTC.

HINT:
·

The ATF temperature can be checked on the GTS display.

·

*1: 150°C (302°F) or higher is indicated regardless of the actual ATF temperature.

·

*2: -40°C (-40°F) is indicated regardless of the actual ATF temperature.



WIRING DIAGRAM

C155188E27
5.509,1.145 5.980,1.347 0.471,0.202 10 THO1 5.112,1.269 5.410,1.471 0.297,0.202 10 114 5.112,2.425 5.410,2.627 0.297,0.202 10 113 3.51,1.269 3.808,1.471 0.297,0.202 10 9 3.51,2.425 3.808,2.627 0.297,0.202 10 10 1.066,1.269 1.233,1.471 0.168,0.202 10 1 5.205,3.78 5.410,3.982 0.206,0.202 10 92 5.509,2.3 5.980,2.502 0.471,0.202 10 THO2 3.05,2.16 3.482,2.362 0.432,0.202 10 OT2+ 1.299,1.005 1.677,1.207 0.378,0.202 10 OT1- 1.296,2.16 1.767,2.362 0.471,0.202 10 OT2- 5.509,3.656 5.980,3.858 0.471,0.202 10 E2 1.604,3.124 2.075,3.326 0.471,0.202 10 C34 1.604,3.31 3.346,3.512 1.742,0.202 10 No. 1 Transmission Wire 1.394,1.498 3.412,1.700 2.017,0.202 10 No. 1 ATF Temperature Sensor 1.394,2.651 3.412,2.853 2.017,0.202 10 No. 2 ATF Temperature Sensor 1.066,2.425 1.233,2.627 0.168,0.202 10 2 3.072,1.005 3.457,1.207 0.385,0.202 10 OT+ 0.047,3.9 0.837,4.102 0.791,0.202 10 *1: for LHD 0.047,4.274 0.837,4.476 0.791,0.202 10 *2: for RHD 5.723,4.341 6.184,4.511 0.461,0.170 10 C46*2 5.723,4.188 6.184,4.358 0.461,0.170 10 C45*1 5.723,4.496 6.145,4.692 0.422,0.195 10 ECM

CAUTION / NOTICE / HINT

DATA LIST


HINT:

Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


a.

Warm up the engine.


b.

Turn the ignition switch off.


c.

Connect the GTS to the DLC3.


d.

Turn the ignition switch to ON.


e.

Turn the GTS on.


f.

Enter the following menus: Powertrain / Engine and ECT / Data List.


g.

According to the display on the GTS, read the Data List.

Engine and ECT
Tester Display Measurement Item/Range Normal Condition Diagnostic Note
A/T Oil Temperature 1 No. 1 ATF temperature sensor value/
Min.: -40°C (-40°F)
Max.: 150°C (302°F)
·

After stall test: Approximately 80°C (176°F)

·

With engine cold: Equal to ambient temperature


If the value is -40°C (-40°F) or 150°C (302°F), the No. 1 ATF temperature sensor circuit is open or shorted.

HINT:

When DTC P0712 is stored and the GTS output is 150°C (302°F) or higher, there is a short circuit.

When DTC P0713 is stored and the GTS output is -40°C (-40°F), there is an open circuit.

Check the temperature displayed on the GTS in order to check if a malfunction exists.


Temperature Displayed Malfunction
-40°C (-40°F) Open circuit
150°C (302°F) or higher Short circuit

If a circuit related to the ATF temperature sensor becomes open, P0713 is immediately stored (in 0.5 seconds). When P0713 is stored, P0711 cannot be stored. It is not necessary to inspect the circuit when P0711 is stored.



PROCEDURE

1.INSPECT NO. 1 TRANSMISSION WIRE (NO. 1 ATF TEMPERATURE SENSOR)
a.
C214326E61
2.13,1.289 1.931,1.745 false 2.248,1.07 2.502,1.745 false 1.694,1.783 2.023,1.950 0.329,0.167 10 OT+ 0.055,0.021 0.279,0.187 0.224,0.167 10 *a 2.362,1.783 2.774,1.950 0.412,0.167 10 OT1-

Disconnect the No. 1 transmission wire connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (OT1-) - 9 (OT+) Always 79 Ω to 156 kΩ
1 (OT1-) - Body ground Always 10 kΩ or higher
9 (OT+) - Body ground Always 10 kΩ or higher


HINT:

If the resistance is out of the specified range at any of the ATF temperatures shown in the table below, the driveability of the vehicle may decrease.


Resistance (Reference):
ATF Temperature Specified Condition
10°C (50°F) 5 to 8 kΩ
25°C (77°F) 2.5 to 4.5 kΩ
110°C (230°F) 0.22 to 0.28 kΩ



Text in Illustration
*a Component without harness connected
(No. 1 transmission wire)


OK

2.CHECK HARNESS AND CONNECTOR (NO. 1 TRANSMISSION WIRE - ECM)

NG

REPAIR OR REPLACE NO. 1 ATF TEMPERATURE SENSOR (NO. 1 TRANSMISSION WIRE)

2.CHECK HARNESS AND CONNECTOR (NO. 1 TRANSMISSION WIRE - ECM)
a.
U165040E01
0.091,0.023 0.386,0.232 0.296,0.208 10 *a 0.95,0.255 1.325,0.488 0.375,0.233 10 C45 1.354,0.255 1.552,0.439 0.198,0.184 10 *1 1.783,0.255 2.158,0.488 0.375,0.233 10 C46 2.187,0.255 2.385,0.439 0.198,0.184 10 *2 1.467,1.66 1.059,1.23 false 1.35,1.676 1.891,1.877 0.542,0.202 10 92 (E2) 0.154,1.679 0.940,1.881 0.786,0.202 10 114 (THO1) 0.986,1.299 0.702,1.686 false

Disconnect the ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
for LHD
Tester Connection Condition Specified Condition
C45-114 (THO1) - C45-92 (E2) Always 79 Ω to 156 kΩ
C45-114 (THO1) - Body ground Always 10 kΩ or higher
C45-92 (E2) - Body ground Always 10 kΩ or higher

for RHD
Tester Connection Condition Specified Condition
C46-114 (THO1) - C46-92 (E2) Always 79 Ω to 156 kΩ
C46-114 (THO1) - Body ground Always 10 kΩ or higher
C46-92 (E2) - Body ground Always 10 kΩ or higher



Text in Illustration
*1 for LHD
*2 for RHD
*a Front view of wire harness connector
(to ECM)


OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR