Home › Drivetrain › AB60F (AUTOMATIC TRANSMISSION / TRANSAXLE) › AUTOMATIC TRANSMISSION SYSTEM(for 1VD-FTV with DPF) › from 2015.08
RM2660E _52 Drivetrain _052805 AB60F AUTOMATIC TRANSMISSION / TRANSAXLE _0255274 AUTOMATIC TRANSMISSION SYSTEM(for 1VD-FTV with DPF) C

AB60F AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM(for 1VD-FTV with DPF)  P0979  Shift Solenoid "C" Control Circuit Low (Shift Solenoid Valve S3)  P0980  Shift Solenoid "C" Control Circuit High (Shift Solenoid Valve S3)  


DESCRIPTION

Shifting from 1st to 6th is performed in combination with the ON and OFF operation of the shift solenoid valves SL1, SL2, S1, S2, S3, S4 and SR, which are controlled by the ECM. If an open or short circuit occurs in any of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be operated safely. Also, the ECM stops sending current to the open or short circuited solenoid (See page Drivetrain>AB60F (AUTOMATIC TRANSMISSION / TRANSAXLE)>AUTOMATIC TRANSMISSION SYSTEM(for 1VD-FTV with DPF)>FAIL-SAFE CHART).

DTC Code DTC Detection Condition Trouble Area
P0979 The ECM detects a short in the solenoid valve S3 circuit 2 times when the solenoid valve S3 is operated (1 trip detection logic).
·

Short in shift solenoid valve S3 circuit

·

Shift solenoid valve S3

·

ECM


P0980 The ECM detects an open in the solenoid valve S3 circuit 2 times when the solenoid valve S3 is not operated (1 trip detection logic).
·

Open in shift solenoid valve S3 circuit

·

Shift solenoid valve S3

·

ECM



MONITOR DESCRIPTION

These DTCs indicate an open or short in the shift solenoid valve S3 circuit. When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem, illuminates the MIL and stores the DTC. When the shift solenoid valve S3 is ON, if its resistance is 8 Ω or less, the ECM determines there is a short in the shift solenoid valve S3 circuit.

When the shift solenoid valve S3 is OFF, if its resistance is 100 kΩ or higher, the ECM determines there is an open in the shift solenoid valve S3 circuit (See page Drivetrain>AB60F (AUTOMATIC TRANSMISSION / TRANSAXLE)>AUTOMATIC TRANSMISSION SYSTEM(for 1VD-FTV with DPF)>FAIL-SAFE CHART).

WIRING DIAGRAM

C178086E35
2.771,0.917 3,1.083 0.229,0.167 10 false 7 5.531,0.906 5.76,1.073 0.229,0.167 10 false 7 2.49,0.677 2.823,0.875 0.333,0.198 10 false S3 5.74,0.813 6.031,1.01 0.292,0.198 10 false S3 1.01,2.542 1.438,2.74 0.427,0.198 10 false C34 1.01,2.708 2.76,2.906 1.75,0.198 10 false No. 1 Transmission Wire 1.01,1.5 2.646,1.74 1.635,0.24 10 false Shift Solenoid Valve S3 5.896,3.031 6.344,3.198 0.448,0.167 10 false C46*2 5.896,2.875 6.344,3.042 0.448,0.167 10 false C45*1 5.896,3.177 6.323,3.375 0.427,0.198 10 false ECM 0.083,3 0.865,3.198 0.781,0.198 10 false *1: for LHD 0.083,3.365 0.865,3.563 0.781,0.198 10 false *2: for RHD

CAUTION / NOTICE / HINT

HINT:

The shift solenoid valve S3 is turned ON/OFF normally when the shift lever is in D:

ECM gear shift command 1st 2nd 3rd 4th 5th 6th
Shift solenoid valve S3 ON ON ON OFF OFF OFF


PROCEDURE

1.INSPECT NO. 1 TRANSMISSION WIRE (SHIFT SOLENOID VALVE S3)
a.
C214326E35
1.346,1.073 1.101,1.745 false 0.954,1.783 1.190,1.950 0.236,0.167 10 S3 0.055,0.021 0.279,0.187 0.224,0.167 10 *a

Disconnect the No. 1 transmission wire connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
7 (S3) - Body ground 20°C (68°F) 11 to 15 Ω


Text in Illustration
*a Component without harness connected
(No. 1 Transmission Wire)



OK

2.CHECK HARNESS AND CONNECTOR (NO. 1 TRANSMISSION WIRE - ECM)

NG

3.INSPECT SHIFT SOLENOID VALVE S3
2.CHECK HARNESS AND CONNECTOR (NO. 1 TRANSMISSION WIRE - ECM)
U165035E02
0.667,1.792 1.125,0.844 false 0.125,0.052 0.417,0.26 0.292,0.208 10 false *a 0.469,1.74 0.969,1.938 0.5,0.198 10 false 7 (S3) 0.948,0.292 1.323,0.521 0.375,0.229 10 false C45 1.354,0.24 1.531,0.469 0.177,0.229 10 false *1 1.792,0.292 2.167,0.521 0.375,0.229 10 false C46 2.198,0.24 2.375,0.469 0.177,0.229 10 false *2

a.

Disconnect the ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
for LHD
Tester Connection Condition Specified Condition
C45-7 (S3) - Body ground 20°C (68°F) 11 to 15 Ω

for RHD
Tester Connection Condition Specified Condition
C46-7 (S3) - Body ground 20°C (68°F) 11 to 15 Ω



Text in Illustration
*1 for LHD
*2 for RHD
*a Front view of wire harness connector
(to ECM)


OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR