35230
1.INSPECT SHIFT SOLENOID VALVE SR
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Solenoid Connector (SR) - Solenoid Body (SR) | 20°C (68°F) | 11 to 15 Ω |
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
|---|---|
·
Battery positive (+) → Shift solenoid valve SR connector ·
Battery negative (-) → Shift solenoid valve SR body |
Valve moves and makes an operating noise |
If the result is not as specified, replace the solenoid valve.
35280
2.INSPECT SHIFT SOLENOID VALVE SLU
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Terminal 1 of shift solenoid valve SLU - terminal 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
|---|---|
·
Battery positive (+) with a 21 W bulb → Terminal 2 ·
Battery negative (-) → Terminal 1 |
Valve moves and makes an operating noise |
If the result is not as specified, replace the solenoid valve.
35210
3.INSPECT SHIFT SOLENOID VALVE SL2
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Terminal 1 of shift solenoid valve SL2 - terminal 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
|---|---|
·
Battery positive (+) with a 21 W bulb → Terminal 1 ·
Battery negative (-) → Terminal 2 |
Valve moves and makes an operating noise |
If the result is not as specified, replace the solenoid valve.
35290
4.INSPECT SHIFT SOLENOID VALVE SLT
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Terminal 1 of shift solenoid valve SLT - terminal 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
|---|---|
·
Battery positive (+) with a 21 W bulb → Terminal 2 ·
Battery negative (-) → Terminal 1 |
Valve moves and makes an operating noise |
If the result is not as specified, replace the solenoid valve.
35210
5.INSPECT SHIFT SOLENOID VALVE SL1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Terminal 1 of shift solenoid valve SL1 - terminal 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
|---|---|
·
Battery positive (+) with a 21 W bulb → Terminal 1 ·
Battery negative (-) → Terminal 2 |
Valve moves and makes an operating noise |
If the result is not as specified, replace the solenoid valve.
35240
6.INSPECT SHIFT SOLENOID VALVE S1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Solenoid Connector (S1) - Solenoid Body (S1) | 20°C (68°F) | 11 to 15 Ω |
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
|---|---|
·
Battery positive (+) → Shift solenoid valve S1 connector ·
Battery negative (-) → Shift solenoid valve S1 body |
Valve moves and makes an operating noise |
If the result is not as specified, replace the solenoid valve.
35250A
7.INSPECT SHIFT SOLENOID VALVE S2
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Solenoid Connector (S2) - Solenoid Body (S2) | 20°C (68°F) | 11 to 15 Ω |
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
|---|---|
·
Battery positive (+) → Shift solenoid valve S2 connector ·
Battery negative (-) → Shift solenoid valve S2 body |
Valve moves and makes an operating noise |
If the result is not as specified, replace the solenoid valve.