Home › Drivetrain › A750F (AUTOMATIC TRANSMISSION / TRANSAXLE) › VALVE BODY ASSEMBLY › 2014.08–2017.08
RM2660E _52 Drivetrain _052806 A750F AUTOMATIC TRANSMISSION / TRANSAXLE _0255283 VALVE BODY ASSEMBLY G

A750F AUTOMATIC TRANSMISSION / TRANSAXLE  VALVE BODY ASSEMBLY  INSPECTION  


PROCEDURE

Hide 35230 1.INSPECT SHIFT SOLENOID VALVE SR

C158386E02
0.197,0 1.754,0.196 1.557,0.196 10 Shift Solenoid Valve SR: 1.768,1.053 1.945,1.258 0.177,0.205 10 (-) 2.488,1.053 2.689,1.254 0.201,0.201 10 (+)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Solenoid Connector (SR) - Solenoid Body (SR) 20°C (68°F) 11 to 15 Ω



b.

Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) → Shift solenoid valve SR connector

·

Battery negative (-) → Shift solenoid valve SR body


Valve moves and makes an operating noise


If the result is not as specified, replace the solenoid valve.


Hide 35280 2.INSPECT SHIFT SOLENOID VALVE SLU

C358283E01
0.74,1.646 0.49,1.167 false 0.979,1.646 1.188,1.167 false 2.844,1.656 3.063,1.177 false 2.583,1.656 2.344,1.167 false 0.5,0.177 2.927,0.531 2.427,0.354 10 false Component without harness connected: (Shift Solenoid Valve SLU) 0.396,0.917 0.563,1.135 0.167,0.219 10 false 2 1.167,0.917 1.333,1.135 0.167,0.219 10 false 1 2.281,0.917 2.448,1.135 0.167,0.219 10 false 2 3.104,0.917 3.271,1.135 0.167,0.219 10 false 1 2.26,2.625 2.427,2.844 0.167,0.219 10 false (+) 2.979,2.625 3.146,2.844 0.167,0.219 10 false (-)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Terminal 1 of shift solenoid valve SLU - terminal 2 20°C (68°F) 5.0 to 5.6 Ω



b.

Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) with a 21 W bulb → Terminal 2

·

Battery negative (-) → Terminal 1


Valve moves and makes an operating noise


If the result is not as specified, replace the solenoid valve.


Hide 35210 3.INSPECT SHIFT SOLENOID VALVE SL2

C358284E01
2.417,1.688 2.615,1.156 false 1.01,1.688 1.208,1.177 false 0.74,1.698 0.5,1.188 false 2.167,1.688 1.958,1.188 false 0.469,0.177 2.917,0.521 2.448,0.344 10 false Component without harness connected: (Shift Solenoid Valve SL2) 2.552,2.719 2.76,2.927 0.208,0.208 10 false (+) 1.854,2.708 2.063,2.917 0.208,0.208 10 false (-) 0.417,0.927 0.625,1.135 0.208,0.208 10 false 2 1.875,0.917 2.083,1.125 0.208,0.208 10 false 2 2.615,0.906 2.823,1.115 0.208,0.208 10 false 1 1.198,0.906 1.406,1.115 0.208,0.208 10 false 1

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Terminal 1 of shift solenoid valve SL2 - terminal 2 20°C (68°F) 5.0 to 5.6 Ω



b.

Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) with a 21 W bulb → Terminal 1

·

Battery negative (-) → Terminal 2


Valve moves and makes an operating noise


If the result is not as specified, replace the solenoid valve.


Hide 35290 4.INSPECT SHIFT SOLENOID VALVE SLT

C358283E02
0.729,1.656 0.49,1.156 false 0.979,1.656 1.188,1.167 false 2.833,1.667 3.063,1.177 false 2.583,1.656 2.344,1.167 false 0.5,0.177 2.927,0.531 2.427,0.354 10 false Component without harness connected: (Shift Solenoid Valve SLT) 0.396,0.917 0.563,1.135 0.167,0.219 10 false 2 1.167,0.917 1.333,1.135 0.167,0.219 10 false 1 2.281,0.917 2.448,1.135 0.167,0.219 10 false 2 3.104,0.917 3.271,1.135 0.167,0.219 10 false 1 2.26,2.625 2.427,2.844 0.167,0.219 10 false (+) 2.979,2.625 3.146,2.844 0.167,0.219 10 false (-)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Terminal 1 of shift solenoid valve SLT - terminal 2 20°C (68°F) 5.0 to 5.6 Ω



b.

Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) with a 21 W bulb → Terminal 2

·

Battery negative (-) → Terminal 1


Valve moves and makes an operating noise


If the result is not as specified, replace the solenoid valve.


Hide 35210 5.INSPECT SHIFT SOLENOID VALVE SL1

C358284E02
2.417,1.688 2.615,1.156 false 1,1.688 1.208,1.177 false 0.75,1.677 0.5,1.188 false 2.146,1.688 1.969,1.188 false 0.469,0.177 2.917,0.521 2.448,0.344 10 false Component without harness connected: (Shift Solenoid Valve SL1) 2.552,2.719 2.76,2.927 0.208,0.208 10 false (+) 1.854,2.708 2.063,2.917 0.208,0.208 10 false (-) 0.417,0.927 0.625,1.135 0.208,0.208 10 false 2 1.875,0.917 2.083,1.125 0.208,0.208 10 false 2 2.615,0.906 2.823,1.115 0.208,0.208 10 false 1 1.198,0.906 1.406,1.115 0.208,0.208 10 false 1

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Terminal 1 of shift solenoid valve SL1 - terminal 2 20°C (68°F) 5.0 to 5.6 Ω



b.

Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) with a 21 W bulb → Terminal 1

·

Battery negative (-) → Terminal 2


Valve moves and makes an operating noise


If the result is not as specified, replace the solenoid valve.


Hide 35240 6.INSPECT SHIFT SOLENOID VALVE S1

C159062E01
2.449,0.726 2.681,0.909 0.231,0.184 10 (+) 0.057,0 1.634,0.186 1.577,0.186 10 Shift Solenoid Valve S1: 3.182,0.726 3.414,0.909 0.231,0.184 10 (-)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Solenoid Connector (S1) - Solenoid Body (S1) 20°C (68°F) 11 to 15 Ω



b.

Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) → Shift solenoid valve S1 connector

·

Battery negative (-) → Shift solenoid valve S1 body


Valve moves and makes an operating noise


If the result is not as specified, replace the solenoid valve.


Hide 35250A 7.INSPECT SHIFT SOLENOID VALVE S2

C158386E01
0.197,0 1.726,0.196 1.529,0.196 10 Shift Solenoid Valve S2: 1.768,1.053 1.945,1.258 0.177,0.205 10 (-) 2.488,1.053 2.689,1.254 0.201,0.201 10 (+)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Solenoid Connector (S2) - Solenoid Body (S2) 20°C (68°F) 11 to 15 Ω



b.

Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) → Shift solenoid valve S2 connector

·

Battery negative (-) → Shift solenoid valve S2 body


Valve moves and makes an operating noise


If the result is not as specified, replace the solenoid valve.