Home › Drivetrain › A750F (AUTOMATIC TRANSMISSION / TRANSAXLE) › AUTOMATIC TRANSMISSION SYSTEM(for 1GR-FE) › 2015.08–2017.08
RM2660E _52 Drivetrain _052806 A750F AUTOMATIC TRANSMISSION / TRANSAXLE _0255290 AUTOMATIC TRANSMISSION SYSTEM(for 1GR-FE) C

A750F AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM(for 1GR-FE)  P2759  Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU)  


DESCRIPTION

The amount of current flow to the solenoid is controlled by the current of the ECM output signal. During the lock-up operation, if the duty ratio increases, the lock-up hydraulic pressure increases.

C261120E02
4.75,2.24 5.063,1.344 5.063,1.344 5.125,1.344 false 4.979,2.385 5.115,2.792 5.115,2.792 5.188,2.792 false 5.698,2.49 5.802,2.802 5.802,2.802 5.865,2.802 false 5.917,2.719 6.802,2.938 0.885,0.219 10 false Solenoid Coil 0.052,0.635 1.302,0.854 1.25,0.219 10 false Hydraulic Pressure 2.521,3 3.083,3.219 0.563,0.219 10 false Current 5.24,2.708 5.771,2.927 0.531,0.219 10 false Sleeve 5.188,1.26 6.021,1.479 0.833,0.219 10 false Spool Valve

DTC Code DTC Detection Condition Trouble Area
P2759 An open or short is detected in the shift solenoid valve SLU circuit for 1 sec. or more while driving (1 trip detection logic).
·

Open or short in shift solenoid valve SLU circuit

·

Shift solenoid valve SLU

·

ECM



MONITOR DESCRIPTION

When an open or short in the shift solenoid valve (SLU) circuit is detected, the ECM determines there is a malfunction. The ECM will turn on the MIL and store this DTC.

WIRING DIAGRAM

C178085E39
2.792,0.958 3.021,1.125 0.229,0.167 10 false 13 0.813,1 1.042,1.167 0.229,0.167 10 false 2 0.813,1.813 1.042,1.979 0.229,0.167 10 false 1 5.458,0.958 5.688,1.125 0.229,0.167 10 false 10 2.323,0.708 2.75,0.906 0.427,0.198 10 false SLU+ 2.813,2.177 3.042,2.344 0.229,0.167 10 false 5 2.323,1.927 2.75,2.125 0.427,0.198 10 false SLU- 5.781,0.823 6.208,1.021 0.427,0.198 10 false SLU+ 5.458,2.177 5.688,2.344 0.229,0.167 10 false 11 5.781,2.031 6.208,2.229 0.427,0.198 10 false SLU- 1.031,2.531 1.458,2.729 0.427,0.198 10 false C34 1.031,2.719 2.729,2.917 1.698,0.198 10 false Transmission Wire 1.021,1.385 2.667,1.615 1.646,0.229 10 false Shift Solenoid Valve SLU 5.927,2.833 6.406,3 0.479,0.167 10 false C45 5.906,3.021 6.333,3.219 0.427,0.198 10 false ECM

PROCEDURE

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLU)
a.
C214326E68
1.544,1.281 1.332,1.745 false 1.669,1.071 1.924,1.745 false 1.095,1.783 1.530,1.950 0.435,0.167 10 SLU+ 0.055,0.021 0.279,0.187 0.224,0.167 10 *a 1.784,1.783 2.208,1.950 0.424,0.167 10 SLU-

Disconnect the transmission wire connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
13 (SLU+) - 5 (SLU-) 20°C (68°F) 5.0 to 5.6 Ω
13 (SLU+) - Body ground Always 10 kΩ or higher
5 (SLU-) - Body ground Always 10 kΩ or higher


Text in Illustration
*a Component without harness connected
(Transmission Wire)



OK

2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)

NG

3.INSPECT SHIFT SOLENOID VALVE SLU
2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
a.
U165063E02
0.885,1.76 1.344,0.854 false 1.417,0.854 1.948,1.771 false 0.094,0.021 0.385,0.229 0.292,0.208 10 false *a 0.552,1.792 1.271,1.99 0.719,0.198 10 false 10 (SLU+) 1.688,1.802 2.365,2 0.677,0.198 10 false 11 (SLU-) 1.469,0.302 1.844,0.531 0.375,0.229 10 false C45

Disconnect the ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C45-10 (SLU+) - C45-11 (SLU-) 20°C (68°F) 5.0 to 5.6 Ω
C45-10 (SLU+) - Body ground Always 10 kΩ or higher
C45-11 (SLU-) - Body ground Always 10 kΩ or higher


Text in Illustration
*a Front view of wire harness connector
(to ECM)



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR