Home › Drivetrain › A750F (AUTOMATIC TRANSMISSION / TRANSAXLE) › AUTOMATIC TRANSMISSION SYSTEM(for 1GR-FE) › 2015.08–2017.08
RM2660E _52 Drivetrain _052806 A750F AUTOMATIC TRANSMISSION / TRANSAXLE _0255290 AUTOMATIC TRANSMISSION SYSTEM(for 1GR-FE) C

A750F AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM(for 1GR-FE)  P0778  Pressure Control Solenoid "B" Electrical (Shift Solenoid Valve SL2)  


DESCRIPTION

Shifting from 1st to 5th is performed in combination with the "ON" and "OFF" operation of the shift solenoid valves SL1, SL2, S1, S2 and SR which are controlled by the ECM. If an open or short circuit occurs in one of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be operated smoothly (See page Drivetrain>A750F (AUTOMATIC TRANSMISSION / TRANSAXLE)>AUTOMATIC TRANSMISSION SYSTEM(for 1GR-FE)>FAIL-SAFE CHART).

DTC Code DTC Detection Condition Trouble Area
P0778
·

The ECM detects an open or short in the shift solenoid valve SL2 circuit while driving and shifting gears (1 trip detection logic).

·

The output signal duty is 100%.


HINT:

The SL2 output signal duty is less than 100% under normal conditions.


·

Open or short in shift solenoid valve SL2 circuit

·

Shift solenoid valve SL2

·

ECM



MONITOR DESCRIPTION

This DTC indicates an open or short in the shift solenoid valve SL2 circuit. The ECM commands gear shifts by turning the shift solenoid valves "ON/OFF". When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem, illuminates the MIL and stores the DTC. The ECM performs the fail-safe function and turns the other normal shift solenoid valves "ON/OFF" (In case of an open or short circuit, the ECM stops sending current to the circuit).

While driving and shifting gears, if the ECM detects an open or short in the shift solenoid valve SL2 circuit, the ECM determines there is a malfunction (See page Drivetrain>A750F (AUTOMATIC TRANSMISSION / TRANSAXLE)>AUTOMATIC TRANSMISSION SYSTEM(for 1GR-FE)>FAIL-SAFE CHART).

WIRING DIAGRAM

C178085E38
2.792,0.948 3.021,1.115 0.229,0.167 10 false 11 0.813,1.021 1.042,1.188 0.229,0.167 10 false 1 0.813,1.813 1.042,1.979 0.229,0.167 10 false 2 5.448,0.958 5.677,1.125 0.229,0.167 10 false 12 2.323,0.708 2.75,0.906 0.427,0.198 10 false SL2+ 2.813,2.167 3.042,2.333 0.229,0.167 10 false 3 2.323,1.917 2.75,2.115 0.427,0.198 10 false SL2- 5.781,0.823 6.208,1.021 0.427,0.198 10 false SL2+ 5.438,2.167 5.667,2.333 0.229,0.167 10 false 13 5.781,2.042 6.208,2.24 0.427,0.198 10 false SL2- 1.031,2.531 1.458,2.729 0.427,0.198 10 false C34 1.031,2.719 2.708,2.917 1.677,0.198 10 false Transmission Wire 1.031,1.396 2.677,1.625 1.646,0.229 10 false Shift Solenoid Valve SL2 5.917,2.844 6.396,3.01 0.479,0.167 10 false C45 5.896,3.042 6.323,3.24 0.427,0.198 10 false ECM

CAUTION / NOTICE / HINT

HINT:

The shift solenoid valve SL2 turns ON/OFF normally when the shift lever is in D.

ECM gear shift command 1st 2nd 3rd 4th 5th
Shift solenoid valve SL2 ON ON ON ON OFF


PROCEDURE

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL2)
a.
C214326E64
1.866,1.306 1.667,1.745 false 1.939,1.087 2.193,1.745 false 1.43,1.783 1.793,1.950 0.363,0.167 10 SL2+ 0.055,0.021 0.279,0.187 0.224,0.167 10 *a 2.053,1.783 2.396,1.950 0.343,0.167 10 SL2-

Disconnect the transmission wire connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
11 (SL2+) - 3 (SL2-) 20°C (68°F) 5.0 to 5.6 Ω
11 (SL2+) - Body ground Always 10 kΩ or higher
3 (SL2-) - Body ground Always 10 kΩ or higher


Text in Illustration
*a Component without harness connected
(Transmission Wire)



OK

2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)

NG

3.INSPECT SHIFT SOLENOID VALVE SL2
2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
a.
U165065E02
1.49,0.854 1.083,1.792 false 1.563,0.854 1.969,1.792 false 0.094,0.042 0.385,0.25 0.292,0.208 10 false *a 1.521,0.313 1.896,0.542 0.375,0.229 10 false C45 0.74,1.823 1.5,1.99 0.76,0.167 10 false 12 (SL2+) 1.792,1.833 2.552,2 0.76,0.167 10 false 13 (SL2-)

Disconnect the ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C45-12 (SL2+) - C45-13 (SL2-) 20°C (68°F) 5.0 to 5.6 Ω
C45-12 (SL2+) - Body ground Always 10 kΩ or higher
C45-13 (SL2-) - Body ground Always 10 kΩ or higher


Text in Illustration
*a Front view of wire harness connector
(to ECM)



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.INSPECT SHIFT SOLENOID VALVE SL2
a.
C197715E08
0.057,0.006 0.374,0.208 0.317,0.202 10 *a 1.757,0.95 2.207,0.362 false 2.238,0.195 2.402,0.397 0.164,0.202 10 1 1.506,0.95 1.056,0.362 false 0.918,0.195 1.082,0.397 0.164,0.202 10 2 1.757,2.946 2.207,2.359 false 2.238,2.192 2.402,2.394 0.164,0.202 10 1 1.506,2.946 1.056,2.359 false 0.918,2.192 1.082,2.394 0.164,0.202 10 2 1.923,3.929 2.147,4.131 0.224,0.202 10 (+) 1.162,3.929 1.386,4.131 0.224,0.202 10 (-)

Remove the shift solenoid valve SL2.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



c.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) with a 21 W bulb → Terminal 1

·

Battery negative (-) → Terminal 2


Valve moves and makes an operating noise



Text in Illustration
*a Component without harness connected
(Shift Solenoid Valve SL2)


OK

NG