35270
1.INSPECT SHIFT SOLENOID VALVE SL1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
| *a | Component without harness connected
(Shift Solenoid Valve SL1) |
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the shift solenoid valve SL1 connector, then check the movement of the valve.
The solenoid makes an operating sound.
If the result is not as specified, replace the shift solenoid valve SL1.
35270
2.INSPECT SHIFT SOLENOID VALVE SL2
Refer to the procedures for the shift solenoid valve SL1.
35270
3.INSPECT SHIFT SOLENOID VALVE SL3
Refer to the procedures for the shift solenoid valve SL1.
35270
4.INSPECT SHIFT SOLENOID VALVE SL4
Refer to the procedures for the shift solenoid valve SL1.
35270
5.INSPECT SHIFT SOLENOID VALVE SL5
Refer to the procedures for the shift solenoid valve SL1.
35280
6.INSPECT SHIFT SOLENOID VALVE SLU
Refer to the procedures for the shift solenoid valve SL1.
35290
7.INSPECT SHIFT SOLENOID VALVE SLT
Refer to the procedures for the shift solenoid valve SL1.
35240
8.INSPECT SHIFT SOLENOID VALVE SC1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Shift solenoid valve SC1 connector terminal - Shift solenoid valve SC1 body | 15 to 25°C (59 to 77°F) | 11 to 15 Ω |
| *a | Component without harness connected
(Shift Solenoid Valve SC1) |
Connect the positive (+) lead to the terminal of the shift solenoid valve SC1 connector, and the negative (-) lead to the shift solenoid valve SC1 body.
The solenoid makes an operating sound.
If the result is not as specified, replace the shift solenoid valve SC1.
35240
9.INSPECT SHIFT SOLENOID VALVE SC2
Refer to the procedures for the shift solenoid valve SC1.