84010D
1.INSPECT INTEGRATION CONTROL AND PANEL ASSEMBLY (w/o Active Height Control)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 5 (E) - 6 (P) | Mode switch
(ECT PWR) on |
Below 1 Ω |
| Release mode switch
(ECT PWR) off |
10 kΩ or higher | |
| 5 (E) - 8 (2nd) | Mode switch being pushed and held
(ECT 2nd) |
Below 1 Ω |
| Mode switch not pushed
(ECT 2nd) |
10 kΩ or higher |
| *a | Component without harness connected
(Integration Control and Panel Assembly) |
If the result is not as specified, replace the integration control and panel assembly.
84010D
2.INSPECT INTEGRATION CONTROL AND PANEL ASSEMBLY (w/ Active Height Control)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 5 (E) - 6 (P) | Mode switch being pushed and held
(SPORTS S/S+) |
Below 1 Ω |
| Mode switch not pushed
(SPORTS S/S+) |
10 kΩ or higher | |
| 5 (E) - 2 (B) | Mode switch being pushed and held
(NORMAL) |
Below 1 Ω |
| Mode switch not pushed
(NORMAL) |
10 kΩ or higher | |
| 5 (E) - 3 (ECU) | Mode switch being pushed and held
(COMF/ECO) |
Below 1 Ω |
| Mode switch not pushed
(COMF/ECO) |
10 kΩ or higher |
| *a | Component without harness connected
(Integration Control and Panel Assembly) |
If the result is not as specified, replace the integration control and panel assembly.