89429A
1.INSPECT TEMPERATURE SENSOR
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - Body ground | Always | 10 kΩ or higher |
| 2 - Body ground | Always | 10 kΩ or higher |
| *a | Component without harness connected
(Temperature Sensor) |
Immerse the sender portion of the temperature sensor in the Toyota Genuine ATF that has been prepared in a container.
While warming the Toyota Genuine ATF, measure the resistance according to the value(s) in the table below.
| Tester Connection | ATF Temperature | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 10.3 to 13.9 kΩ |
| 115°C (239°F) | 657.1 to 726.3 Ω |
Do not overheat. Otherwise, fire may occur.
If the result is not as specified, replace the temperature sensor.