Refer to DTC P0711 (See page Drivetrain>AE80F (AUTOMATIC TRANSMISSION / TRANSAXLE)>AUTOMATIC TRANSMISSION SYSTEM>P0711).
| DTC No. | DTC Detection Condition
1.
Diagnosis Condition 2.
Malfunction Status 3.
Malfunction Time 4.
Other |
Trouble Area |
|---|---|---|
| P0712 | 1.
The battery voltage is 9.5 V or higher. 2.
No. 1 ATF temperature sensor voltage is below 0.08 V 3.
60 seconds 4.
1-trip detection logic |
·
Short in No. 1 ATF temperature sensor circuit ·
No. 1 ATF temperature sensor (transmission wire) ·
TCM |
| P0713 | 1.
The battery voltage is 9.5 V or higher, engine speed is more than 400 rpm and shift lever in D. 2.
No. 1 ATF temperature sensor voltage is higher than 4.94 V 3.
12 seconds 4.
1-trip detection logic |
·
Open in No. 1 ATF temperature sensor circuit ·
No. 1 ATF temperature sensor (transmission wire) ·
TCM |
The No. 1 ATF temperature sensor converts the ATF temperature to an electrical resistance value. Based on the resistance, the TCM determines the ATF temperature and detects an open or short in the No. 1 ATF temperature sensor circuit. If the resistance value of the No. 1 ATF temperature sensor is below 79 Ω*1 or higher than 156 kΩ*2, the TCM interprets this as a fault in the No. 1 ATF temperature sensor or wiring. The TCM will illuminate the MIL and store the DTC.
*1: 171°C (339.8°F) or higher is indicated regardless of the actual ATF temperature.
*2: -40°C (-40°F) is indicated regardless of the actual ATF temperature.
The ATF temperature can be checked on the GTS display.
Perform registration and/or initialization when parts related to the automatic transmission are replaced (See page Drivetrain>AE80F (AUTOMATIC TRANSMISSION / TRANSAXLE)>AUTOMATIC TRANSMISSION SYSTEM>INITIALIZATION).
After performing repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Start the engine.
Wait for 60 seconds or more with the shift lever in D.
Check for DTCs again (See page Drivetrain>AE80F (AUTOMATIC TRANSMISSION / TRANSAXLE)>AUTOMATIC TRANSMISSION SYSTEM>DTC CHECK / CLEAR).
DATA LIST
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
Warm up the engine.
Turn the engine switch off.
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / ECT / Data List / A/T Oil Temperature 1.
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| A/T Oil Temperature 1 | No. 1 ATF temperature sensor value/
Min.: -40°C (-40°F) Max.: 171°C (339.8°F) |
·
After stall speed test: Approximately 80°C (176°F) ·
While engine is cold: Equal to ambient temperature |
If value is -40°C (-40°F) or 171°C (339.8°F), No. 1 ATF temperature sensor circuit is open or short circuited. |
When DTC P0712 is output and the GTS shows 171°C (339.8°F) or higher, there is a short circuit.
When DTC P0713 is output and the GTS shows -40°C (-40°F), there is an open circuit.
Check the temperature displayed on the GTS in order to check if a malfunction exists.
| Temperature Displayed | Malfunction |
|---|---|
| -40°C (-40°F) | Open or short circuit |
| 171°C (339.8°F) or higher | Short circuit |
If a circuit related to the No. 1 ATF temperature sensor becomes open, P0713 will be stored in approximately 0.5 seconds. It is not necessary to inspect the circuit when P0711 is output.
Warm up the engine.
Turn the engine switch off.
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / ECT / Data List / A/T Oil Temperature 1.
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| A/T Oil Temperature 1 | No. 1 ATF temperature sensor value/
Min.: -40°C (-40°F) Max.: 171°C (339.8°F) |
·
After stall speed test: Approximately 80°C (176°F) ·
While engine is cold: Equal to ambient temperature |
If value is -40°C (-40°F) or 171°C (339.8°F), No. 1 ATF temperature sensor circuit is open or short circuited |
| Result | Proceed to |
|---|---|
| Data List value is not within the normal condition | A |
| Data List value is within the normal condition | B |
A
B
Disconnect the TCM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A80-23 (THO1) - A80-24 (E2) | Always | 79 Ω to 156 kΩ |
| A80-23 (THO1) - Body ground | Always | 10 kΩ or higher |
| A80-24 (E2) - Body ground | Always | 10 kΩ or higher |
If the resistance is out of the specified range at any of the ATF temperatures shown in the table below, the driveability of the vehicle may decrease.
| ATF Temperature | Specified Condition |
|---|---|
| 10°C (50°F) | 5 to 8 kΩ |
| 25°C (77°F) | 2.5 to 4.5 kΩ |
| 110°C (230°F) | 0.22 to 0.28 kΩ |
| *a | Rear view of wire harness connector
(to TCM) |
OK
NG
Disconnect the C171 transmission wire connector.
Disconnect the A80 TCM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C171-1 (OT+) - A80-23 (THO1) | Always | Below 1 Ω |
| C171-2 (OT-) - A80-24 (E2) | Always | Below 1 Ω |
| C171-1 (OT+) or A80-23 (THO1) - Body ground | Always | 10 kΩ or higher |
| C171-2 (OT-) or A80-24 (E2) - Body ground | Always | 10 kΩ or higher |
OK
NG