Home › Drivetrain › AE80F (AUTOMATIC TRANSMISSION / TRANSAXLE) › AUTOMATIC TRANSMISSION SYSTEM › from 2015.08
RM2660E _52 Drivetrain _052807 AE80F AUTOMATIC TRANSMISSION / TRANSAXLE _0255308 AUTOMATIC TRANSMISSION SYSTEM C

AE80F AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM  P2716  Pressure Control Solenoid "D" Electrical  


DESCRIPTION

Refer to DTC P2714 (See page Drivetrain>AE80F (AUTOMATIC TRANSMISSION / TRANSAXLE)>AUTOMATIC TRANSMISSION SYSTEM>P2714).

DTC No. DTC Detection Condition
1.

Diagnosis Condition

2.

Malfunction Status

3.

Malfunction Time

4.

Other


Trouble Area
P2716
1.

Engine is running

2.

Shift solenoid valve SLT circuit is open or shorted

3.

2 seconds

4.

1-trip detection logic


·

Shift solenoid valve SLT

·

Transmission wire

·

Harness or connector

·

TCM



MONITOR DESCRIPTION

When an open or short in the shift solenoid valve SLT circuit is detected, the TCM determines that there is a malfunction. The TCM will illuminate the MIL and store this DTC.

WIRING DIAGRAM

C343212E25
5.188,1.125 5.698,1.333 0.51,0.208 10 false SLT+ 3.469,1.146 3.979,1.354 0.51,0.208 10 false SLT+ 1.083,1.25 1.594,1.458 0.51,0.208 10 false 2 1.083,2.146 1.594,2.354 0.51,0.208 10 false 1 4.979,1.125 5.49,1.333 0.51,0.208 10 false 5 3.927,1.125 4.438,1.333 0.51,0.208 10 false 11 5.188,2.083 5.698,2.292 0.51,0.208 10 false SLT- 5.615,3.01 6.125,3.219 0.51,0.208 10 false A80 5.615,3.198 6.125,3.406 0.51,0.208 10 false TCM 3.5,2.104 4.01,2.313 0.51,0.208 10 false SLT- 1.49,1.677 3.302,1.885 1.813,0.208 10 false Shift Solenoid Valve SLT 4.979,2.083 5.49,2.292 0.51,0.208 10 false 4 3.927,2.094 4.438,2.302 0.51,0.208 10 false 12 1.74,2.646 2.25,2.854 0.51,0.208 10 false C171 1.74,2.833 3.073,3.042 1.333,0.208 10 false Transmission Wire

CAUTION / NOTICE / HINT

NOTICE:

Perform registration and/or initialization when parts related to the automatic transmission are replaced (See page Drivetrain>AE80F (AUTOMATIC TRANSMISSION / TRANSAXLE)>AUTOMATIC TRANSMISSION SYSTEM>INITIALIZATION).


HINT:

After performing repair, clear the DTCs and perform the following procedure to check that DTCs are not output.



PROCEDURE

1.CHECK HARNESS AND CONNECTOR (SHIFT SOLENOID VALVE SLT - TCM)
a.
U165637E02
1.073,1.948 1.594,2.927 false 1.01,1.948 0.49,2.927 false 0.125,0.052 0.406,0.229 0.281,0.177 10 false *a 0.167,2.938 0.938,3.125 0.771,0.188 10 false 5 (SLT+) 1.365,2.958 2.052,3.146 0.688,0.188 10 false 4 (SLT-) 0.854,0.177 1.208,0.354 0.354,0.177 10 false A80

Disconnect the TCM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A80-5 (SLT+) - A80-4 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
A80-5 (SLT+) or A80-4 (SLT-) - Body ground Always 10 kΩ or higher


Text in Illustration
*a Rear view of wire harness connector
(to TCM)



OK

NG

2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - TCM)
2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - TCM)
a.

Disconnect the C171 transmission wire connector.


b.

Disconnect the A80 TCM connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C171-11 (SLT+) - A80-5 (SLT+) Always Below 1 Ω
C171-12 (SLT-) - A80-4 (SLT-) Always Below 1 Ω
C171-11 (SLT+) or A80-5 (SLT+) - Body ground Always 10 kΩ or higher
C171-12 (SLT-) or A80-4 (SLT-) - Body ground Always 10 kΩ or higher




OK

3.INSPECT SHIFT SOLENOID VALVE SLT

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.INSPECT SHIFT SOLENOID VALVE SLT
a.
C209928E13
0.057,0.005 0.374,0.207 0.317,0.202 10 *a 1.757,0.949 2.207,0.361 false 2.238,0.194 2.402,0.396 0.164,0.202 10 1 1.506,0.949 1.056,0.361 false 0.918,0.194 1.082,0.396 0.164,0.202 10 2 1.757,2.945 2.207,2.358 false 2.238,2.191 2.402,2.393 0.164,0.202 10 1 1.506,2.945 1.056,2.358 false 0.918,2.191 1.082,2.393 0.164,0.202 10 2 1.923,3.928 2.122,4.130 0.200,0.202 10 (-) 1.119,3.928 1.339,4.130 0.221,0.202 10 (+)

Remove the shift solenoid valve SLT (See page Drivetrain>AE80F (AUTOMATIC TRANSMISSION / TRANSAXLE)>VALVE BODY ASSEMBLY>DISASSEMBLY).


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Terminal 1 of the shift solenoid valve SLT - Terminal 2 20°C (68°F) 5.0 to 5.6 Ω



c.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) with a 21 W bulb → Terminal 2

·

Battery negative (-) → Terminal 1


Valve moves and makes an operating noise



Text in Illustration
*1 Shift Solenoid Valve SLT


OK

NG