Home › Drivetrain › AE80F (AUTOMATIC TRANSMISSION / TRANSAXLE) › AUTOMATIC TRANSMISSION SYSTEM › from 2015.08
RM2660E _52 Drivetrain _052807 AE80F AUTOMATIC TRANSMISSION / TRANSAXLE _0255308 AUTOMATIC TRANSMISSION SYSTEM C

AE80F AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM  P2742  Transmission Fluid Temperature Sensor "B" Circuit Low  P2743  Transmission Fluid Temperature Sensor "B" Circuit High  


DESCRIPTION

The No. 2 ATF temperature sensor is on the transmission, just in front of the oil cooler inlet pipeline.

If the TCM detects an abnormally high ATF temperature near this sensor, it illuminates the warning indicator.

HINT:
·

The temperature of ATF easily rises when towing, climbing hills, in traffic, etc.

·

If the No. 2 ATF temperature sensor becomes short-circuited, the signal that indicates that the ATF temperature is 193°C (379.4°F) or higher is input into the TCM.



Vehicle conditions when the sensor is normal and when the sensor is short-circuited are indicated in the table below.

No. 2 ATF Temperature Sensor State Detection Condition Symptom Recovery Condition
Sensor is normal ATF temperature higher than 150°C (302°F) ATF temperature warning indicator remains on ATF temperature below 135°C (275°F)*1
ATF temperature higher than 130°C (266°F) Shift point too high ATF temperature below 110°C (230°F)
When conditions (a) and (b) are satisfied.
(a) ATF temperature higher than 130°C (266°F)
(b) Engine coolant temperature higher than 95°C (203°F)
Lock-up at 3rd gear*2 ATF temperature below 110°C (230°F)*1 and engine coolant temperature higher than 95°C (203°F)
Sensor is short-circuited Any conditions
·

ATF temperature warning indicator remains on

·

Shift point too high


Symptoms still occur
Engine coolant temperature higher than 95°C (203°F) Lock-up at 3rd gear*2 Symptoms still occur

HINT:

*1: When the ATF is normal, it decreases to below 135°C (275°F) within 5 minutes with the shift lever in P or N in an idling state.

*2: When the ATF temperature is normal, transmission lock-up occurs in 5th, 6th, 7th or 8th gear with the shift lever in D or with the S8 range selected, in 5th, 6th or 7th gear with the S7 range selected, in 5th or 6th gear with the S6 range selected and in 5th gear with the S5 range selected.


DTC Code DTC Detection Condition
1.

Diagnosis Condition

2.

Malfunction Status

3.

Malfunction Time

4.

Other


Trouble Area
P2742
1.

The battery voltage is 9.5 V or higher.

2.

No. 2 ATF temperature sensor voltage is below 0.08 V

3.

60 seconds

4.

1-trip detection logic


·

Short in No. 2 ATF temperature sensor circuit

·

No. 2 ATF temperature sensor

·

TCM


P2743
1.

The battery voltage is 9.5 V or higher, engine speed is more than 400 rpm and shift lever in D.

2.

No. 2 ATF temperature sensor voltage is higher than 4.94 V

3.

12 seconds

4.

1-trip detection logic


·

Open in No. 2 ATF temperature sensor circuit

·

No. 2 ATF temperature sensor

·

TCM



MONITOR DESCRIPTION

The No. 2 ATF temperature sensor converts the ATF temperature into an electrical resistance value. Based on the resistance, the TCM determines the ATF temperature, and the TCM detects an open or short in the No. 2 ATF temperature sensor circuit. If the resistance value of the No. 2 ATF temperature sensor is below 79 Ω*1 or higher than 156 kΩ*2, the TCM interprets this as a fault in the No. 2 ATF temperature sensor or wiring. The TCM stores a DTC.

HINT:
·

*1: 193°C (379.4°F) or higher is indicated regardless of the actual ATF temperature.

·

*2: -40°C (-40°F) is indicated regardless of the actual ATF temperature.

·

The ATF temperature can be checked on the GTS display.



WIRING DIAGRAM

C342950E03
5.608,3.13 6.117,3.332 0.509,0.202 10 TCM 5.608,2.943 6.117,3.145 0.509,0.202 10 A80 5.199,1.064 5.708,1.265 0.509,0.202 10 THOC 2.151,1.064 2.660,1.265 0.509,0.202 10 OT2+ 2.184,2.039 2.693,2.240 0.509,0.202 10 OT2- 0.776,2.82 3.123,3.022 2.347,0.202 10 No. 2 ATF Temperature Sensor 4.908,1.064 5.232,1.265 0.323,0.202 10 26 5.903,0.899 6.226,1.101 0.323,0.202 10 5 V 2.644,1.064 2.967,1.265 0.324,0.202 10 1 2.642,2.039 2.965,2.240 0.324,0.202 10 2 4.909,2.039 5.186,2.240 0.277,0.202 10 25 5.198,2.039 5.706,2.240 0.509,0.202 10 ETH2 0.776,2.633 1.285,2.835 0.509,0.202 10 C172

CAUTION / NOTICE / HINT

NOTICE:

Perform registration and/or initialization when parts related to the automatic transmission are replaced (See page Drivetrain>AE80F (AUTOMATIC TRANSMISSION / TRANSAXLE)>AUTOMATIC TRANSMISSION SYSTEM>INITIALIZATION).


HINT:

After performing repair, clear the DTCs and perform the following procedure to check that DTCs are not output.

1.

Start the engine.

2.

Wait for 60 seconds or more with the shift lever in D.



DATA LIST


NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


HINT:

Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


a.

Warm up the engine.


b.

Turn the engine switch off.


c.

Connect the GTS to the DLC3.


d.

Turn the engine switch on (IG).


e.

Turn the GTS on.


f.

Enter the following menus: Powertrain / ECT / Data List / A/T Oil Temperature 3.


g.

According to the display on the GTS, read the Data List.

ECT
Tester Display Measurement Item/Range Normal Condition Diagnostic Note
A/T Oil Temperature 3 No. 2 ATF temperature sensor value/
Min.: -40°C (-40°F)
Max.: 193°C (379.4°F)
·

After stall speed test: Approximately 80°C (176°F)

·

While engine is cold: Equal to ambient temperature


If value is -40°C (-40°F) or 193°C (379.4°F), No. 2 ATF temperature sensor circuit is open or short circuited

HINT:
·

When DTC P2742 is stored and the GTS shows 193°C (379.4°F) or higher, there is a short circuit.

·

When DTC P2743 is stored and the GTS shows -40°C (-40°F), there is an open circuit.

Check the temperature displayed on the GTS in order to check if a malfunction exists.



Temperature Displayed Malfunction
-40°C (-40°F) Open or short circuit
193°C (379.4°F) or higher Short circuit



PROCEDURE

1.READ VALUE USING GTS (A/T OIL TEMPERATURE 3)
a.

Warm up the engine.


b.

Turn the engine switch off.


c.

Connect the GTS to the DLC3.


d.

Turn the engine switch on (IG).


e.

Turn the GTS on.


f.

Enter the following menus: Powertrain / ECT / Data List / A/T Oil Temperature 3.


g.

According to the display on the GTS, read the Data List.

ECT
Tester Display Measurement Item/Range Normal Condition Diagnostic Note
A/T Oil Temperature 3 No. 2 ATF temperature sensor value/
Min.: -40°C (-40°F)
Max.: 193°C (379.4°F)
·

After stall speed test: Approximately 80°C (176°F)

·

While engine is cold: Equal to ambient temperature


If value is -40°C (-40°F) or 193°C (379.4°F), No. 2 ATF temperature sensor circuit is open or short circuited

Result
Result Proceed to
Data List value is not within the normal condition A
Data List value is within the normal condition B



A

2.CHECK HARNESS AND CONNECTOR (NO. 2 ATF TEMPERATURE SENSOR - TCM)

B

2.CHECK HARNESS AND CONNECTOR (NO. 2 ATF TEMPERATURE SENSOR - TCM)
a.
U165638E02
1.198,2.073 1.635,2.927 false 1.135,2.073 0.698,2.927 false 0.125,0.052 0.406,0.229 0.281,0.177 10 false *a 1.354,2.958 2.125,3.146 0.771,0.188 10 false 25 (ETH2) 0.25,2.948 1.125,3.135 0.875,0.188 10 false 26 (THOC) 0.865,0.188 1.219,0.365 0.354,0.177 10 false A80

Disconnect the TCM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A80-26 (THOC) - A80-25 (ETH2) Always 79 Ω to 156 kΩ
A80-26 (THOC) - Body ground Always 10 kΩ or higher
A80-25 (ETH2) - Body ground Always 10 kΩ or higher


HINT:

If the resistance is out of the specified range at any of the ATF temperatures shown in the table below, the driveability of the vehicle may decrease.


ATF Temperature Specified Condition
20°C (68°F) 10.3 to 13.9 kΩ
110°C (230°F) 0.68 to 0.88 kΩ


Text in Illustration
*a Rear view of wire harness connector
(to TCM)


OK

NG

3.CHECK HARNESS AND CONNECTOR (NO. 2 ATF TEMPERATURE SENSOR - TCM)
3.CHECK HARNESS AND CONNECTOR (NO. 2 ATF TEMPERATURE SENSOR - TCM)
a.

Disconnect the C172 No. 2 ATF temperature sensor connector.


b.

Disconnect the A80 TCM connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C172-1 (OT2+) - A80-26 (THOC) Always Below 1 Ω
C172-2 (OT2-) - A80-25 (ETH2) Always Below 1 Ω
C172-1 (OT2+) or A80-26 (THOC) - Body ground Always 10 kΩ or higher
C172-2 (OT2-) or A80-25 (ETH2) - Body ground Always 10 kΩ or higher




OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR