Home › Drivetrain › AXLE AND DIFFERENTIAL › REAR DIFFERENTIAL LOCK ACTUATOR(w/ Differential Lock)
RM2660E _52 Drivetrain _052812 AXLE AND DIFFERENTIAL _0255349 REAR DIFFERENTIAL LOCK ACTUATOR(w/ Differential Lock) G

AXLE AND DIFFERENTIAL  REAR DIFFERENTIAL LOCK ACTUATOR(w/ Differential Lock)  INSPECTION  


PROCEDURE

Hide 41450 1.INSPECT DIFFERENTIAL LOCK SHIFT ACTUATOR

a.

Check the free to lock switch.

i.

Connect lines via a relay as shown in the illustration, and check that the actuator fork moves from the free to lock position.

NOTICE:
·

Make sure to perform this inspection with the actuator removed from the vehicle. If this inspection is performed with the actuator installed to the vehicle, the actuator will be damaged.

·

When inspecting the actuator, make sure to operate it with the lines connected via a relay. If the lines are not connected via a relay and battery voltage is directly applied to the actuator, the actuator will be damaged.



HINT:

When performing the operation described above, use the DEFOG relay.


C175671E02
0.906,3.958 0.969,3.958 0.969,3.958 1.104,4.354 false 1.667,3.896 1.583,3.896 1.583,3.896 1.469,4.333 false 0.854,5.052 0.948,5.052 0.948,5.052 1.188,4.677 false 1.625,4.688 2.052,5.052 2.052,5.052 2.125,5.052 false 1.417,4.688 1.417,5.302 false 6.021,3.25 5.594,2.875 5.594,2.875 5.521,2.875 false 6.083,3.594 6.594,2.854 6.594,2.854 6.698,2.854 false 6.417,3.563 6.698,3.563 false 6.01,3.958 6.313,4.385 6.313,4.385 6.385,4.385 false 5.729,3.594 5.115,3.594 false 5.583,2.198 6.542,2.396 0.958,0.198 10 false DEFOG Relay: 5.406,2.792 5.594,2.969 0.188,0.177 10 false 1 6.438,4.302 6.604,4.5 0.167,0.198 10 false 2 6.76,2.771 6.906,2.938 0.146,0.167 10 false 4 6.76,3.479 6.927,3.667 0.167,0.188 10 false 5 4.958,3.531 5.125,3.688 0.167,0.156 10 false 3 0.365,0.083 2.906,0.438 2.542,0.354 10 false Component without harness connected: (Differential Lock Shift Actuator) 2.667,1.344 3.542,1.563 0.875,0.219 10 false Free → Lock: 0.677,3.896 0.927,4.083 0.25,0.188 10 false M1 1.708,3.823 2,3.969 0.292,0.146 10 false M2 0.479,4.979 0.875,5.135 0.396,0.156 10 false RLY1 1.25,5.365 1.656,5.542 0.406,0.177 10 false RLY2 2.177,5 2.573,5.156 0.396,0.156 10 false GND


ii.

After the free to lock switch is complete, check the limit switch of the shift actuator.

Standard Resistance:
Tester Connection Condition Specified Condition
5 (RLY2) - 4 (GND) After free to lock switch is complete Below 12.5 Ω
6 (RLY1) - 4 (GND) After free to lock switch is complete 500 kΩ or higher


If the result is not as specified, replace the differential lock shift actuator assembly.



b.

Check the lock to free switch.

i.

Connect lines via a relay as shown in the illustration, and check that the actuator fork moves from the lock to free position.

NOTICE:
·

Make sure to perform this inspection with the actuator removed from the vehicle. If this inspection is performed with the actuator installed to the vehicle, the actuator will be damaged.

·

When inspecting the actuator, make sure to operate it with the lines connected via a relay. If the lines are not connected via a relay and battery voltage is directly applied to the actuator, the actuator will be damaged.



HINT:

When performing the operation described above, use the DEFOG relay.


C175672E02
1.01,3.896 1.063,3.896 1.063,3.896 1.208,4.281 false 1.76,3.823 1.677,3.823 1.677,3.823 1.573,4.271 false 0.948,4.979 1.052,4.979 1.052,4.979 1.292,4.604 false 1.719,4.615 2.146,4.969 2.146,4.969 2.229,4.969 false 1.563,4.604 1.76,5.26 1.76,5.26 1.865,5.26 false 6.115,3.177 5.74,2.802 5.74,2.802 5.677,2.802 false 6.177,3.51 6.76,2.76 6.76,2.76 6.823,2.76 false 6.51,3.5 6.844,3.5 false 6.115,3.896 6.5,4.302 6.5,4.302 6.583,4.302 false 5.823,3.521 5.302,3.521 false 5.688,2.115 6.656,2.313 0.969,0.198 10 false DEFOG Relay: 5.583,2.74 5.771,2.917 0.188,0.177 10 false 1 6.615,4.24 6.781,4.438 0.167,0.198 10 false 2 6.875,2.698 7.021,2.865 0.146,0.167 10 false 4 6.885,3.406 7.052,3.594 0.167,0.188 10 false 5 5.177,3.448 5.344,3.604 0.167,0.156 10 false 3 0.354,0 2.896,0.354 2.542,0.354 10 false Component without harness connected: (Differential Lock Shift Actuator) 0.771,3.823 1.021,4.01 0.25,0.188 10 false M1 1.802,3.76 2.094,3.906 0.292,0.146 10 false M2 0.573,4.906 0.969,5.063 0.396,0.156 10 false RLY1 1.938,5.198 2.344,5.375 0.406,0.177 10 false RLY2 2.271,4.927 2.667,5.083 0.396,0.156 10 false GND 2.552,1.344 3.448,1.563 0.896,0.219 10 false Free ← Lock:


ii.

After the lock to free switch is complete, check the limit switch of the shift actuator.

Standard Resistance:
Tester Connection Condition Specified Condition
5 (RLY2) - 4 (GND) After lock to free switch is complete 500 kΩ or higher
6 (RLY1) - 4 (GND) After lock to free switch is complete Below 12.5 Ω


If the result is not as specified, replace the differential lock shift actuator assembly.