Home › Suspension › SUSPENSION CONTROL › ACTIVE HEIGHT CONTROL PUMP AND MOTOR
RM2660E _53 Suspension _052813 SUSPENSION CONTROL _0255369 ACTIVE HEIGHT CONTROL PUMP AND MOTOR G

SUSPENSION CONTROL  ACTIVE HEIGHT CONTROL PUMP AND MOTOR  INSPECTION  


PROCEDURE

Hide 48910A 1.INSPECT HEIGHT CONTROL PUMP AND MOTOR

a.
C177053E01
0.201,0.116 2.736,0.702 2.534,0.586 10 Component without harness connected: (Height Control Pump and Motor) 2.792,2.595 2.883,2.797 0.091,0.202 10 - 0.465,2.618 0.584,2.866 0.119,0.248 10 + 1.396,2.114 0.525,2.469 0.525,2.469 0.525,2.549 false 2.061,2.103 2.828,2.457 2.828,2.457 2.828,2.56 false

Check the pump and motor operation.

i.

Apply battery voltage to the pump and motor and check the operating sound of the height control pump and motor.

NOTICE:
·

Be careful of fluid spray when the height control pump and motor is operated.

·

Do not allow the motor to operate for 60 seconds or more.

·

If the height control pump and motor is shorted, locked, or has a similar type of malfunction, a large amount of current will be flowing. Therefore, if the motor does not operate, immediately stop this inspection.



OK:
Measurement Condition Specified Condition
Battery positive (+) → Terminal 2
Battery negative (-) → Terminal 1
Motor operates


If the result is not as specified, replace the height control pump and motor.