Home › Suspension › SUSPENSION CONTROL › HEIGHT CONTROL ACCUMULATOR
RM2660E _53 Suspension _052813 SUSPENSION CONTROL _0255370 HEIGHT CONTROL ACCUMULATOR N

SUSPENSION CONTROL  HEIGHT CONTROL ACCUMULATOR  DISPOSAL  


PROCEDURE

Hide 49130F 1.DISPOSE OF SUSPENSION CONTROL PUMP ACCUMULATOR ASSEMBLY

C174594E01
1.276,1.507 1.396,1.649 0.119,0.142 10 A 1.861,1.521 1.981,1.663 0.119,0.142 10 B 0.11,1.802 1.235,1.968 1.125,0.165 10 100 mm (3.94 in.) 1.523,1.883 1.674,1.883 false 1.674,1.888 1.674,1.373 false

a.

Place the accumulator in a vise and saw a hole between A and B shown in the illustration using a saw to discharge the gas inside.

CAUTION:
·

Before discharging the gas, loosen the bleeder plug to bleed high pressure oil.

·

The gas is colorless, odorless and harmless.

·

Saw a hole while covering the saw with a cloth because chips may fly up.