89406
1.INSPECT FRONT HEIGHT CONTROL SENSOR SUB-ASSEMBLY LH
Do not drop the height control sensor. If it is dropped, replace it with a new one.
Connect 3 dry batteries of 1.5 V in series.
Connect the positive (+) end of the batteries to terminal 3 (SHB) of the height control sensor and the negative (-) end of the batteries to terminal 1 (SHG). While slowly moving the sensor link up and down, measure the voltage between terminal 2 (SHFR*1, SHFL*2) and terminal 1 (SHG).
*1: for RH
*2: for LH
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2 (SHFR) - 1 (SHG) | Max. HI | Approx. 4.1 V |
| Normal | Approx. 2.25 V | |
| Min. LO | Approx. 0.45 V |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2 (SHFL) - 1 (SHG) | Max. HI | Approx. 4.1 V |
| Normal | Approx. 2.25 V | |
| Min. LO | Approx. 0.45 V |
Do not apply a voltage of higher than 6 V.
If the result is not as specified, replace the front height control sensor.