Home › Suspension › SUSPENSION CONTROL › DAMPING FORCE CONTROL ACTUATOR(for Rear Side)
RM2660E _53 Suspension _052813 SUSPENSION CONTROL _0255379 DAMPING FORCE CONTROL ACTUATOR(for Rear Side) N

SUSPENSION CONTROL  DAMPING FORCE CONTROL ACTUATOR(for Rear Side)  DISPOSAL  


PROCEDURE

Hide 49151B 1.DISPOSE OF REAR SUSPENSION CONTROL ACCUMULATOR

C179742E02
1.354,1.698 1.896,1.698 false 1.896,1.698 1.896,1.125 false 2.802,1.844 2.906,1.844 false 2.906,1.844 2.906,1.604 false 2.906,1.604 2.406,1.135 false 0.344,1.615 1.385,1.771 1.042,0.156 10 false 40 mm (1.58 in.) 1.708,1.76 2.833,1.906 1.125,0.146 10 false 20 mm (0.787 in.) 1.479,1.229 1.594,1.365 0.115,0.135 10 false A 2.25,1.229 2.365,1.375 0.115,0.146 10 false B

a.

Place the accumulator in a vise and saw a hole between A and B shown in the illustration using a saw to discharge the gas inside.

CAUTION:
·

The gas is colorless, odorless and harmless.

·

Saw a hole while covering the saw with a cloth because chips may fly up.




Hide 49158D 2.DISPOSE OF REAR NO. 3 SUSPENSION CONTROL ACCUMULATOR

C174071E02
1.24,0.333 1.427,0.333 false 1.417,0.323 1.531,0.677 false 0.375,0.25 1.271,0.406 0.896,0.156 10 false Hatched Area

a.

Place the gas camber in a vise and saw a hole in the hatched area shown in the illustration using a saw to discharge the gas inside.

CAUTION:
·

The gas is colorless, odorless and harmless.

·

Saw a hole while covering the saw with a cloth because chips may fly up.