Home › Steering › STEERING COLUMN › HEATED STEERING WHEEL SYSTEM
RM2660E _55 Steering _052826 STEERING COLUMN _0255459 HEATED STEERING WHEEL SYSTEM U

STEERING COLUMN  HEATED STEERING WHEEL SYSTEM  FAIL-SAFE CHART  


MALFUNCTION DETECTION


a.

Operation when malfunction is detected

Content Operation
When thermistor trouble is detected Heater off
When overheating (175°C (347°F)) of controller is detected Heater off
When load short current (50 A or more) is detected Heater off
When undervoltage (4.5 V) is detected Heater off
OFF timer (30 min.) After preset time of timer passes, heater off
Reverse voltage protection Protection circuit operates


b.

Malfunction detection conditions

i.

When an open or short in the steering wheel thermistor continues for 2 seconds or more.


ii.

When the steering heater switch momentary switch is pressed continuously for 10 seconds or more.



c.

Malfunction display

i.

The LED of the steering heater switch blinks at 0.3 second intervals.



d.

Restore condition

i.

If the normal condition is restored for 2 seconds or more, the previous operation before the malfunction occurred continues. However, regardless of if a malfunction is detected and the malfunction operation is occurring, and regardless of if the normal condition is restored and the system is operating normally, the timer will turn off the heater 30 minutes after the switch was first turned on.