Home › Power Source / Network › 1VD-FTV (BATTERY / CHARGING) › CHARGING SYSTEM
RM2660E _57 Power Source / Network _052833 1VD-FTV BATTERY / CHARGING _0255522 CHARGING SYSTEM L

1VD-FTV BATTERY / CHARGING  CHARGING SYSTEM  PRECAUTION  


IGNITION SWITCH EXPRESSION


HINT:

The type of ignition switch used on this model differs depending on the specifications of the vehicle. The expressions listed in the table below are used in this section.

Expression Ignition Switch (Position) Engine Switch (Condition)
Ignition Switch off LOCK Off
Ignition Switch ACC ACC On (ACC)
Ignition Switch ON ON On (IG)
Engine Start START Start



PRECAUTION


a.

Check that the battery cables are connected to the correct terminals.


b.

Disconnect the battery cables when the battery is given a quick charge.


c.

Do not perform tests with a high voltage insulation resistance tester.


d.

Never disconnect the battery while the engine is running.


e.

Check that the charging cable nut is securely installed to terminal B of the generator and the relay block.