The main body ECU receives switch signals from the multiplex network master switch, and driver side door key cylinder switch signals from the front door lock. The main body ECU activates the door lock motor on each door according to these signals.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Since the power door lock control system has functions that use LIN communication, first confirm that there is no malfunction in the communication system by inspecting the LIN communication functions in accordance with the "How to Proceed with Troubleshooting" procedures. Then, conduct the following inspection procedure.
| Result | Proceed to |
|---|---|
| All doors cannot be locked through multiplex network master switch and driver side door key cylinder | A |
| All doors cannot be locked through multiplex network master switch (for Models with Jam Protection Function on Driver Door Window Only) | B |
| All doors cannot be locked through multiplex network master switch (for Models with Jam Protection Function on 4 Windows) | C |
| All doors cannot be locked through driver side door key cylinder | D |
A
B
C
D
Disconnect the 2A, 2B and 2D main body ECU connectors.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2A-1 (ALTB) - Body ground | Always | 11 to 14 V |
| 2B-20 (BATB) - Body ground | Always | 11 to 14 V |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2D-62 (GND2) - Body ground | Always | Below 1 Ω |
OK
NG
for LHD:
Disconnect the I31 master switch connector.
Disconnect the 2D main body ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| I31-9 (UL) - 2D-52 (UL1) | Always | Below 1 Ω |
| I31-2 (L) - 2D-49 (L1) | Always | Below 1 Ω |
| I31-1 (E) - Body ground | Always | Below 1 Ω |
| I31-9 (UL) - Body ground | Always | 10 kΩ or higher |
| I31-2 (L) - Body ground | Always | 10 kΩ or higher |
for RHD:
Disconnect the I26 master switch connector.
Disconnect the 2D main body ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| I26-8 (UL) - 2D-52 (UL1) | Always | Below 1 Ω |
| I26-2 (L) - 2D-49 (L1) | Always | Below 1 Ω |
| I26-9 (E) - Body ground | Always | Below 1 Ω |
| I26-8 (UL) - Body ground | Always | 10 kΩ or higher |
| I26-2 (L) - Body ground | Always | 10 kΩ or higher |
OK
NG
Replace the multiplex network master switch with a normally functioning one (See page Vehicle Exterior>WINDOW / GLASS>POWER WINDOW MASTER SWITCH>REMOVAL).
Check that all doors can be locked and unlocked by using the multiplex network master switch.
All doors can be locked and unlocked with multiplex network master switch.
OK
NG
Use the Data List to check if the door key linked lock and unlock switches are functioning properly.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Door Key Linked Lock SW | Door key linked lock switch signal / ON or OFF | ON: Driver side door key cylinder turned to lock position
OFF: Driver side door key cylinder not turned |
- |
| Door Key Linked Unlock SW | Door key linked unlock switch signal / ON or OFF | ON: Driver side door key cylinder turned to unlock position
OFF: Driver side door key cylinder not turned |
- |
On tester screen, each item changes between ON and OFF according to above chart.
OK
NG
for LHD:
Disconnect the I14 door lock connector.
Disconnect the E1 and 2D main body ECU connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| I14-10 (UL) - E1-10 (UL3) | Always | Below 1 Ω |
| I14-9 (L) - 2D-53 (L2) | Always | Below 1 Ω |
| I14-7 (E) - Body ground | Always | Below 1 Ω |
| I14-10 (UL) - Body ground | Always | 10 kΩ or higher |
| I14-9 (L) - Body ground | Always | 10 kΩ or higher |
for RHD:
Disconnect the I6 door lock connector.
Disconnect the E1 and 2D main body ECU connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| I6-5 (UL) - E1-10 (UL3) | Always | Below 1 Ω |
| I6-6 (L) - 2D-53 (L2) | Always | Below 1 Ω |
| I6-8 (E) - Body ground | Always | Below 1 Ω |
| I6-5 (UL) - Body ground | Always | 10 kΩ or higher |
| I6-6 (L) - Body ground | Always | 10 kΩ or higher |
OK
NG
for LHD (w/o Double Locking Function):
Remove the front door lock LH (See page Vehicle Interior>DOOR LOCK>FRONT DOOR LOCK>REMOVAL).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 9 (L) - 7 (E) | Lock | Below 1 Ω |
| 9 (L) - 7 (E) | Off | 10 kΩ or higher |
| 10 (UL) - 7 (E) | Unlock | Below 1 Ω |
| 10 (UL) - 7 (E) | Off | 10 kΩ or higher |
for LHD (w/ Double Locking Function):
Remove the front door lock LH (See page Vehicle Interior>DOOR LOCK>FRONT DOOR LOCK>REMOVAL).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 9 (L) - 7 (E) | Lock | Below 1 Ω |
| 9 (L) - 7 (E) | Off | 10 kΩ or higher |
| 10 (UL) - 7 (E) | Unlock | Below 1 Ω |
| 10 (UL) - 7 (E) | Off | 10 kΩ or higher |
for RHD (w/o Double Locking Function):
Remove the front door lock RH (See page Vehicle Interior>DOOR LOCK>FRONT DOOR LOCK>REMOVAL).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 5 (UL) - 8 (E) | Unlock | Below 1 Ω |
| 5 (UL) - 8 (E) | Off | 10 kΩ or higher |
| 6 (L) - 8 (E) | Lock | Below 1 Ω |
| 6 (L) - 8 (E) | Off | 10 kΩ or higher |
for RHD (w/ Double Locking Function):
Remove the front door lock LH (See page Vehicle Interior>DOOR LOCK>FRONT DOOR LOCK>REMOVAL).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 5 (UL) - 8 (E) | Unlock | Below 1 Ω |
| 5 (UL) - 8 (E) | Off | 10 kΩ or higher |
| 6 (L) - 8 (E) | Lock | Below 1 Ω |
| 6 (L) - 8 (E) | Off | 10 kΩ or higher |
OK
NG