This circuit provides power to operate the certification ECU (smart key ECU assembly).
Remove the IMB fuse from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| IMB fuse | Always | Below 1 Ω |
OK
NG
Disconnect the E29 ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E29-17 (E) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E29-1 (+B) - Body ground | Always | 11 to 14 V |
OK
NG