81240
1.INSPECT NO. 1 ROOM LIGHT ASSEMBLY (for LED Type)
w/ Spot Light:
Apply battery voltage to the connector and check the light illumination condition.
| Measurement Condition | Condition | Specified Condition |
|---|---|---|
| Battery positive (+) → 3 (B)
Battery negative (-) → 1 (E) |
Spot light switch RH on | Illuminates (RH side) |
| Spot light switch LH on | Illuminates (LH side) |
If the result is not as specified, replace the No. 1 room light assembly.
| *a | Component without harness connected
(No. 1 Room Light Assembly) |
w/o Spot Light:
Apply battery voltage to the connector and check the light illumination condition.
| Measurement Condition | Condition | Specified Condition |
|---|---|---|
| Battery positive (+) → 2 (DL)
Battery negative (-) → 4 (DB) |
Room light switch on | Room light illuminates |
If the result is not as specified, replace the No. 1 room light assembly.
| *a | Component without harness connected
(No. 1 Room Light Assembly) |