81290
1.INSPECT NO. 3 ROOM LIGHT ASSEMBLY (for LED Type)
Inspect the room light.
Apply battery voltage to the connector and check the light illumination condition.
| Measurement Condition | Condition | Specified Condition |
|---|---|---|
| Battery positive (+) → 2 (DL)
Battery negative (-) → 4 (DB) |
Room light switch on | Room light illuminates |
If the result is not as specified, replace the No. 3 room light assembly.
| *a | Component without harness connected
(No. 3 Room Light Assembly) |
Inspect the room light (for Door-linked).
Apply battery voltage to the connector and check the light illumination condition.
| Measurement Condition | Condition | Specified Condition |
|---|---|---|
| Battery positive (+) → 4 (DB))
Battery negative (-) → 3 (L) |
Room light switch on | Room light illuminates |
If the result is not as specified, replace the No. 3 room light assembly.
| *a | Component without harness connected
(No. 3 Room Light Assembly) |