74310
1.INSPECT VISOR ASSEMBLY RH
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2 (SW) - 1 (GND) | Visor raised | 10 kΩ or higher |
| 2 (SW) - 1 (GND) | Visor lowered and mirror cover closed | 10 kΩ or higher |
| 2 (SW) - 1 (GND) | Visor lowered and mirror cover open | Below 1 Ω |
If the result is not as specified, there may be a malfunction in the visor assembly.
74330C
2.INSPECT VISOR ASSEMBLY LH
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2 (SW) - 1 (GND) | Visor raised | 10 kΩ or higher |
| 2 (SW) - 1 (GND) | Visor lowered and mirror cover closed | 10 kΩ or higher |
| 2 (SW) - 1 (GND) | Visor lowered and mirror cover open | Below 1 Ω |
If the result is not as specified, there may be a malfunction in the visor assembly.