Home › Vehicle Interior › METER / GAUGE / DISPLAY › LIGHT CONTROL RHEOSTAT
RM2660E _58 Vehicle Interior _052841 METER / GAUGE / DISPLAY _0255596 LIGHT CONTROL RHEOSTAT G

METER / GAUGE / DISPLAY  LIGHT CONTROL RHEOSTAT  INSPECTION  


PROCEDURE

Hide 84119 1.INSPECT LIGHT CONTROL RHEOSTAT

a.

Inspect the light control rheostat.

i.

Measure the resistance according to the value(s) in the table below.

E154786E02
1.733,4.198 3.018,4.363 1.286,0.165 10 TAIL Cancel Switch 5.079,2.014 5.290,2.165 0.211,0.151 10 TC 4.496,2.016 4.722,2.163 0.225,0.147 10 TR 5.628,1.716 5.764,1.867 0.135,0.151 10 T 5.616,1.025 5.749,1.181 0.133,0.156 10 E 3.897,1.024 4.146,1.185 0.248,0.161 10 A/B 5.097,1.333 5.583,1.1 false 4.649,1.333 4.163,1.1 false 5.578,1.767 5.093,1.534 false 4.939,1.546 5.149,1.971 false 4.817,1.546 4.607,1.971 false 3.635,0.171 6.125,0.521 2.489,0.350 10 Component without harness connected: (Light Control Rheostat) 0.729,1.674 0.891,1.823 0.163,0.149 10 0° 0.974,1.324 1.220,1.473 0.246,0.149 10 30° 2.592,1.716 2.908,1.865 0.316,0.149 10 250° 2.144,1.996 2.737,2.145 0.593,0.149 10 27° +/-5° 1.793,2.62 2.456,2.769 0.663,0.149 10 300° +/-5° 3.38,4.602 3.543,4.751 0.163,0.149 10 0° 3.718,3.811 3.964,3.959 0.246,0.149 10 30° 5.408,3.811 5.724,3.959 0.316,0.149 10 250° 6.221,4.602 6.814,4.751 0.593,0.149 10 27° +/-5° 5.59,4.805 6.253,4.954 0.663,0.149 10 300° +/-5° 6.017,3.703 6.849,3.859 0.832,0.156 10 Below 100 Ω 6.017,2.573 6.896,2.729 0.878,0.156 10 10 kΩ +/-20% 3.134,3.997 3.354,4.163 0.221,0.165 10 On 3.134,4.448 3.354,4.613 0.221,0.165 10 Off 3.638,5.263 4.053,5.428 0.415,0.165 10 Bright 5.076,5.268 5.418,5.433 0.341,0.165 10 Dark 4.096,4.576 5.131,4.742 1.036,0.165 10 Operating Angle

Standard Resistance:
Tester Connection Switch Condition Specified Condition
6 (TC) - 1 (E) TAIL cancel switch off → on 10 kΩ or higher → Below 1 Ω
5 (T) - 1 (E) Always 10 kΩ or higher
7 (TR) - 1 (E) Light control rheostat fully turned right → fully turned left 10 kΩ or higher → Below 100 Ω




b.

Inspect the trip switch.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
4 (A/B) - 1 (E) Trip switch on (Pushed) Below 200 Ω
Trip switch off (Not Pushed) 1 MΩ or higher


If the result is not as specified, replace the rheostat.