84920
1.INSPECT LUMBAR SWITCH LH (for LHD)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 3 (B) - 4 (H) | Hold | Below 1 Ω |
| 1 (R) - 2 (E2) | ||
| 1 (R) - 2 (E2) | Off | |
| 4 (H) - 5 (E2) | ||
| 1 (R) - 3 (B) | Release | |
| 4 (H) - 5 (E2) |
If the result is not as specified, replace the lumbar switch.
84920
2.INSPECT LUMBAR SWITCH RH (for RHD)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 3 (B) - 4 (H) | Hold | Below 1 Ω |
| 1 (R) - 2 (E) | ||
| 1 (R) - 2 (E) | Off | |
| 4 (H) - 5 (E) | ||
| 1 (R) - 3 (B) | Release | |
| 4 (H) - 5 (E) |
If the result is not as specified, replace the lumbar switch.