Home › Vehicle Interior › HEATING / AIR CONDITIONING › FRONT EVAPORATOR TEMPERATURE SENSOR(for RHD)
RM2660E _58 Vehicle Interior _052847 HEATING / AIR CONDITIONING _0255688 FRONT EVAPORATOR TEMPERATURE SENSOR(for RHD) G

HEATING / AIR CONDITIONING  FRONT EVAPORATOR TEMPERATURE SENSOR(for RHD)  INSPECTION  


PROCEDURE

Hide 88625 1.INSPECT FRONT EVAPORATOR TEMPERATURE SENSOR

a.

Measure the resistance according to the value(s) in the table below.

E345466E03
0.49,1.958 0.688,1.615 0.688,1.615 0.938,1.615 false 3.906,0.448 5.104,0.635 1.198,0.188 10 false Resistance (kΩ) 3.885,0.792 4.177,0.969 0.292,0.177 10 false 10.0 0.979,1.531 1.49,1.698 0.51,0.167 10 false Sensor 3.948,2.594 4.188,2.771 0.24,0.177 10 false 0.0 3.938,2.396 4.177,2.573 0.24,0.177 10 false 1.0 3.938,2.208 4.177,2.385 0.24,0.177 10 false 2.0 3.938,2.042 4.177,2.219 0.24,0.177 10 false 3.0 3.938,1.865 4.177,2.042 0.24,0.177 10 false 4.0 3.938,1.698 4.177,1.875 0.24,0.177 10 false 5.0 3.938,1.521 4.177,1.698 0.24,0.177 10 false 6.0 3.927,1.344 4.167,1.521 0.24,0.177 10 false 7.0 3.938,1.177 4.177,1.354 0.24,0.177 10 false 8.0 3.938,0.979 4.177,1.156 0.24,0.177 10 false 9.0 4.771,2.708 5.01,2.885 0.24,0.177 10 false 0 5.323,2.719 5.563,2.896 0.24,0.177 10 false 10 5.896,2.708 6.135,2.885 0.24,0.177 10 false 20 6.5,2.708 6.74,2.885 0.24,0.177 10 false 30 4.208,2.708 4.448,2.885 0.24,0.177 10 false -10 4.208,2.865 4.583,3.063 0.375,0.198 10 false (14) 4.719,2.865 5.063,3.083 0.344,0.219 10 false (32) 5.313,2.875 5.656,3.104 0.344,0.229 10 false (50) 5.875,2.865 6.167,3.073 0.292,0.208 10 false (68) 6.469,2.865 6.74,3.073 0.271,0.208 10 false (86) 5.938,3.25 6.521,3.438 0.583,0.188 10 false °C (°F) 5.115,3.25 5.969,3.417 0.854,0.167 10 false Temperature

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 -10°C (14°F) 7.30 to 9.10 kΩ
1 - 2 -5°C (23°F) 5.65 to 6.95 kΩ
1 - 2 0°C (32°F) 4.40 to 5.35 kΩ
1 - 2 5°C (41°F) 3.40 to 4.15 kΩ
1 - 2 10°C (50°F) 2.70 to 3.25 kΩ
1 - 2 15°C (59°F) 2.14 to 2.58 kΩ
1 - 2 20°C (68°F) 1.71 to 2.05 kΩ
1 - 2 25°C (77°F) 1.38 to 1.64 kΩ
1 - 2 30°C (86°F) 1.11 to 1.32 kΩ


If the result is not as specified, replace the front evaporator temperature sensor.

NOTICE:
·

Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.


·

When measuring, the sensor temperature must be almost the same as the ambient temperature.



HINT:

As the temperature increases, the resistance decreases (see the graph).