Home › Vehicle Interior › HEATING / AIR CONDITIONING › ROOM TEMPERATURE SENSOR(for Rear Side)
RM2660E _58 Vehicle Interior _052847 HEATING / AIR CONDITIONING _0255691 ROOM TEMPERATURE SENSOR(for Rear Side) G

HEATING / AIR CONDITIONING  ROOM TEMPERATURE SENSOR(for Rear Side)  INSPECTION  


PROCEDURE

Hide 88625C 1.INSPECT ROOM TEMPERATURE SENSOR

E345463E01
0.458,0.448 2.896,0.823 2.438,0.375 10 false Component without harness connected: (Room Temperature Sensor) 4.125,0.313 5.146,0.5 1.021,0.188 10 false Resistance (kΩ) 3.854,0.635 4.073,0.813 0.219,0.177 9 false 4.0 3.865,2.531 4.073,2.698 0.208,0.167 9 false 0.0 3.865,2.281 4.073,2.448 0.208,0.167 9 false 0.5 3.865,2.063 4.073,2.229 0.208,0.167 9 false 1.0 3.854,1.813 4.063,1.979 0.208,0.167 9 false 1.5 3.854,1.573 4.063,1.74 0.208,0.167 9 false 2.0 3.865,1.344 4.073,1.51 0.208,0.167 9 false 2.5 3.854,1.104 4.063,1.271 0.208,0.167 9 false 3.0 3.854,0.865 4.063,1.031 0.208,0.167 9 false 3.5 4.156,2.667 4.365,2.833 0.208,0.167 9 false 10 4.542,2.667 4.75,2.833 0.208,0.167 9 false 20 5.031,2.677 5.24,2.844 0.208,0.167 9 false 30 5.5,2.667 5.708,2.833 0.208,0.167 9 false 40 5.969,2.656 6.177,2.823 0.208,0.167 9 false 50 6.438,2.656 6.646,2.823 0.208,0.167 9 false 60 4.125,2.833 4.375,3 0.25,0.167 9 false (50) 4.521,2.833 4.771,3 0.25,0.167 9 false (68) 5.021,2.833 5.271,3 0.25,0.167 9 false (86) 5.438,2.833 5.771,3 0.333,0.167 9 false (104) 5.906,2.833 6.24,3 0.333,0.167 9 false (122) 6.385,2.833 6.719,3 0.333,0.167 9 false (140) 5.615,3.125 6.375,3.313 0.76,0.188 10 false Temperature 6.427,3.146 6.656,3.49 0.229,0.344 9 false °C (°F)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 10°C (50°F) 3.00 to 3.73 kΩ
1 - 2 15°C (59°F) 2.45 to 2.88 kΩ
1 - 2 20°C (68°F) 1.95 to 2.30 kΩ
1 - 2 25°C (77°F) 1.60 to 1.80 kΩ
1 - 2 30°C (86°F) 1.28 to 1.47 kΩ
1 - 2 35°C (95°F) 1.00 to 1.22 kΩ
1 - 2 40°C (104°F) 0.80 to 1.00 kΩ
1 - 2 45°C (113°F) 0.65 to 0.85 kΩ
1 - 2 50°C (122°F) 0.50 to 0.70 kΩ
1 - 2 55°C (131°F) 0.44 to 0.60 kΩ
1 - 2 60°C (140°F) 0.36 to 0.50 kΩ


If the result is not as specified, replace the room temperature sensor.

NOTICE:
·

Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.

·

When measuring, the sensor temperature must be the same as the ambient temperature.



HINT:

As the temperature increases, the resistance decreases (See the graph).