Home › Vehicle Interior › HEATING / AIR CONDITIONING › AMBIENT TEMPERATURE SENSOR › 2014.08–2015.08
RM2660E _58 Vehicle Interior _052847 HEATING / AIR CONDITIONING _0255692 AMBIENT TEMPERATURE SENSOR G

HEATING / AIR CONDITIONING  AMBIENT TEMPERATURE SENSOR  INSPECTION  


PROCEDURE

Hide 88625P 1.INSPECT AMBIENT TEMPERATURE SENSOR

E349494E02
1.896,1.271 2.219,1.271 2.219,1.271 2.823,2.167 false 0.146,0.094 2.583,0.458 2.438,0.365 10 false Component without harness connected: (Ambient Temperature Sensor) 1.063,1.167 2.188,1.375 1.125,0.208 10 false Sensor Area 4.51,0.417 5.635,0.625 1.125,0.208 10 false Resistance (kΩ) 5.208,3.083 6.333,3.292 1.125,0.208 10 false Temperature °C 5.99,3.25 6.354,3.469 0.365,0.219 10 false (°F) 4.292,0.74 4.573,0.958 0.281,0.219 10 false 4.0 4.281,0.927 4.563,1.146 0.281,0.219 10 false 3.5 4.281,1.135 4.563,1.354 0.281,0.219 10 false 3.0 4.281,1.365 4.563,1.583 0.281,0.219 10 false 2.5 4.281,1.583 4.563,1.802 0.281,0.219 10 false 2.0 4.281,1.823 4.563,2.042 0.281,0.219 10 false 1.5 4.281,2.042 4.563,2.26 0.281,0.219 10 false 1.0 4.292,2.292 4.573,2.51 0.281,0.219 10 false 0.5 4.281,2.5 4.563,2.719 0.281,0.219 10 false 0.0 4.542,2.604 4.76,2.771 0.219,0.167 10 false 10 4.896,2.604 5.115,2.771 0.219,0.167 10 false 20 5.375,2.604 5.594,2.771 0.219,0.167 10 false 30 5.833,2.615 6.052,2.781 0.219,0.167 10 false 40 6.302,2.615 6.521,2.781 0.219,0.167 10 false 50 6.656,2.615 6.875,2.781 0.219,0.167 10 false 60 4.552,2.76 4.771,2.927 0.219,0.167 10 false 50 4.906,2.76 5.125,2.927 0.219,0.167 10 false 68 5.385,2.76 5.604,2.927 0.219,0.167 10 false 86 5.781,2.771 6.094,2.979 0.313,0.208 10 false 104 6.26,2.76 6.573,2.969 0.313,0.208 10 false 122 6.615,2.76 6.927,2.969 0.313,0.208 10 false 140

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 10°C (50°F) 3.00 to 3.73 kΩ
15°C (59°F) 2.45 to 2.88 kΩ
20°C (68°F) 1.95 to 2.30 kΩ
25°C (77°F) 1.60 to 1.80 kΩ
30°C (86°F) 1.28 to 1.47 kΩ
35°C (95°F) 1.00 to 1.22 kΩ
40°C (104°F) 0.80 to 1.00 kΩ
45°C (113°F) 0.65 to 0.85 kΩ
50°C (122°F) 0.50 to 0.70 kΩ
55°C (131°F) 0.44 to 0.60 kΩ
60°C (140°F) 0.36 to 0.50 kΩ


If the result is not as specified, replace the ambient temperature sensor.

NOTICE:
·

Touching the sensor even slightly may change the resistance value. Hold the connector of the sensor.


·

When measuring the resistance, the sensor temperature must be the same as the ambient temperature.



HINT:

As the temperature increases, the resistance decreases (See the graph).