Hide 88625U 1.INSPECT DUCT TEMPERATURE SENSOR

E345468E01
4.292,0.865 4.51,0.865 false 5.219,2.594 5.219,2.177 false 0.292,0.208 2.729,0.583 2.438,0.375 10 false Component without harness connected: (Duct Temperature Sensor) 4.24,0.281 5.271,0.458 1.031,0.177 10 false Resistance (kΩ) 4.583,0.771 6.51,0.948 1.927,0.177 10 false Maximum permissible value line 4.344,2.604 6.271,2.781 1.927,0.177 10 false Maximum permissible value line 4.719,3.385 5.5,3.563 0.781,0.177 10 false Temperature 4.063,2.656 4.177,2.833 0.115,0.177 10 false 1 4.073,2.844 4.198,3.021 0.125,0.177 10 false 0 4.073,2.438 4.188,2.615 0.115,0.177 10 false 2 4.073,2.229 4.188,2.406 0.115,0.177 10 false 3 4.073,1.823 4.188,1.99 0.115,0.167 10 false 5 4.073,2.021 4.188,2.198 0.115,0.177 10 false 4 4.073,1.625 4.188,1.792 0.115,0.167 10 false 6 4.073,1.406 4.188,1.573 0.115,0.167 10 false 7 4.073,1.208 4.188,1.375 0.115,0.167 10 false 8 4.073,1.031 4.188,1.198 0.115,0.167 10 false 9 4.021,0.813 4.177,0.979 0.156,0.167 10 false 10 4.021,0.615 4.167,0.781 0.146,0.167 10 false 11 4.635,2.969 4.813,3.146 0.177,0.177 10 false 20 4.198,3.104 4.448,3.292 0.25,0.188 10 false (50) 5.115,2.969 5.292,3.146 0.177,0.177 10 false 30 5.594,2.969 5.771,3.146 0.177,0.177 10 false 40 6.042,2.969 6.219,3.146 0.177,0.177 10 false 50 6.5,2.958 6.677,3.135 0.177,0.177 10 false 60 4.229,2.958 4.406,3.135 0.177,0.177 10 false 10 4.615,3.115 4.865,3.302 0.25,0.188 10 false (68) 5.094,3.115 5.344,3.302 0.25,0.188 10 false (86) 5.521,3.104 5.844,3.292 0.323,0.188 10 false (104) 5.958,3.115 6.271,3.302 0.313,0.188 10 false (122) 6.406,3.104 6.729,3.292 0.323,0.188 10 false (140) 5.521,3.396 5.771,3.74 0.25,0.344 10 false °C (°F)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 at 10°C (50°F) 9.4 to 10.5 kΩ
1 - 2 at 15°C (59°F) 7.5 to 8.3 kΩ
1 - 2 at 20°C (68°F) 6.0 to 6.5 kΩ
1 - 2 at 25°C (77°F) 4.8 to 5.2 kΩ
1 - 2 at 30°C (86°F) 3.8 to 4.2 kΩ
1 - 2 at 35°C (95°F) 3.1 to 3.4 kΩ
1 - 2 at 40°C (104°F) 2.5 to 2.8 kΩ
1 - 2 at 45°C (113°F) 2.0 to 2.3 kΩ
1 - 2 at 50°C (122°F) 1.6 to 2.0 kΩ
1 - 2 at 55°C (131°F) 1.3 to 1.6 kΩ
1 - 2 at 60°C (140°F) 1.1 to 1.4 kΩ


If the result is not as specified, replace the duct temperature sensor.

NOTICE:
·

Touching the sensor even slightly may change the resistance value. Hold the connector of the sensor.

·

When measuring the resistance, the sensor temperature must be the same as the ambient temperature.



HINT:

As the temperature increases, the resistance decreases (See the graph).