Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) › from 2015.08
RM2660E _58 Vehicle Interior _052847 HEATING / AIR CONDITIONING _0255699 AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) U

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)  DATA LIST / ACTIVE TEST  


HINT:

Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


DATA LIST


a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Data List.


e.

Enter the following menus: Powertrain / Engine and ECT / Data List.


f.

According to the display on the GTS, read the Data List.

Air Conditioner
Tester Display Measurement Item/Range Normal Condition Diagnostic Note
Room Temperature Sensor Cooler thermistor (room temperature sensor) / Min.: -6.5°C (20.3°F), Max.: 57.25°C (135.05°F) Actual room temperature for front seat displayed Cooler thermistor (room temperature sensor) system malfunction:
·

Open in the circuit: -6.5°C (20.3°F)

·

Short in the circuit: 57.25°C (135.05°F)


Ambient Temp Sensor Cooler thermistor (ambient temperature sensor) / Min.: -23.3°C (-9.94°F), Max.: 65.95°C (150.71°F) Actual ambient temperature displayed Thermistor assembly (ambient temperature sensor) system malfunction:
·

Open in the circuit: -23.3°C (-9.94°F)

·

Short in the circuit: 65.95°C (150.71°F)


Adjusted Ambient Temp Adjusted ambient temperature /Min.: -30.8°C (-23.44°F), Max.: 50.8°C (123.44°F) Adjusted ambient temperature displayed Air conditioning amplifier assembly
Evaporator Fin Thermistor No. 1 cooler thermistor (evaporator temperature sensor) / Min.: -29.7°C (-21.46°F), Max.: 59.55°C (139.19°F) Actual evaporator temperature displayed No. 1 cooler thermistor (evaporator temperature sensor) system malfunction:
·

Open in the circuit: -29.7°C (-21.46°F)

·

Short in the circuit: 59.55°C (139.19°F)


Engine Coolant Temp Engine coolant temperature / Min.: 1.3°C (34.34°F), Max.: 90.55°C (194.99°F) Actual engine coolant temperature displayed while engine warmed up
·

SFI system malfunction

·

CAN communication system malfunction


Blower Motor Speed Level Blower with fan motor sub-assembly speed level / Min.: 0 level, Max.: 31 level Displayed speed level increases in range between 0 and 31 as blower with fan motor subassembly speed increases Displayed speed level increases in range between 0 and 31 as blower with fan motor subassembly speed increases
Regulator Pressure Sensor Air conditioner pressure sensor / Min.: 0.4566 MPa, Max.: 3.2943 MPa Actual refrigerant pressure displayed
·

Air conditioning system (leaks, blocked)

·

Air conditioner pressure sensor system malfunction


Room Temp Sensor (Rear) Cooler thermistor (No. 2 room temperature sensor) / Min.: -6.5°C (20.3°F), Max.: 57.25°C (135.05°F) Actual rear room temperature seat displayed Cooler thermistor (No. 2 room temperature sensor) system malfunction:
·

Open in the circuit: -6.5°C (20.3°F)

·

Short in the circuit: 57.25°C (135.05°F)


Evap Temp Sensor (Rear) No. 2 air conditioning harness assembly (rear evaporator temperature sensor) / Min.: -29.7°C (-21.46°F), Max.: 59.55°C (139.19°F) Actual rear evaporator temperature displayed No. 2 air conditioning harness assembly (rear evaporator temperature sensor) system malfunction:
·

Open in the circuit: -29.7°C (-21.46°F)

·

Short in the circuit: 59.55°C (139.19°F)


Blower Motor Level (Rear) Rear blower with fan motor sub-assembly speed level / Min.: 0, Max.: 31 Displayed speed level increases in range between 0 and 31 as rear blower with fan motor subassembly speed increases Rear blower with fan motor sub-assembly system malfunction
Air Outlet Servo Pulse (R) Rear mode damper servo motor target pulse / Min.: 128, Max.:383
·

FACE: 276 (pulse)

·

B/L: 235 (pulse)

·

FOOT: 200 (pulse)


·

Displayed between 200 and 276 pulse

·

Rear mode damper servo motor system malfunction

·

w/ Rear Heater


Air Outlet Servo Actual Pulse(R) Rear mode damper servo motor actual pulse / Min.: 128, Max.:383
·

FACE: 276 (pulse)

·

B/L: 235 (pulse)

·

FOOT: 200 (pulse)


·

Displayed between 200 and 276 pulse

·

Rear mode damper servo motor system malfunction

·

w/ Rear Heater


Air Mix Servo Targ Pulse(R) Rear air mix damper servo motor LH*1 or RH*2 target pulse / Min.: 128, Max.:383
for LHD:
·

MAX COLD: 254 (pulse)

·

MAX HOT: 299 (pulse)


for RHD:
·

MAX COLD: 258 (pulse)

·

MAX HOT: 213 (pulse)


·

Displayed between 254 and 299 pulse (for LHD)

·

Displayed between 213 and 258 pulse (for RHD)

·

Rear air mix damper servo motor LH*1 or RH*2 system malfunction

·

w/ Rear Heater


Air Mix Servo Actual Pulse(R) Rear air mix damper servo motor LH*1 or RH*2 actual pulse / Min.: 128, Max.:383
for LHD:
·

MAX COLD: 254 (pulse)

·

MAX HOT: 299 (pulse)


for RHD:
·

MAX COLD: 258 (pulse)

·

MAX HOT: 213 (pulse)


·

Displayed between 254 and 299 pulse (for LHD)

·

Displayed between 213 and 258 pulse (for RHD)

·

Rear air mix damper servo motor LH*1 or RH*2 system malfunction


Air Mix Servo Targ Pulse(D) Air mix damper servo motor LH*1 or RH*2 target pulse / Min.: 128, Max.:383
for LHD:
·

MAX COLD: 331 (pulse)

·

MAX HOT: 249 (pulse)


for RHD:
·

MAX COLD: 181 (pulse)

·

MAX HOT: 263 (pulse)


·

Displayed between 249 and 331 pulse (for LHD)

·

Displayed between 181 and 263 pulse (for RHD)

·

Air mix damper servo motor LH*1 or RH*2 system malfunction


Air Mix Servo Actual Pulse(D) Air mix damper servo motor LH*1 or RH*2 actual pulse / Min.: 128, Max.:383
for LHD:
·

MAX COLD: 331 (pulse)

·

MAX HOT: 249 (pulse)


for RHD:
·

MAX COLD: 181 (pulse)

·

MAX HOT: 263 (pulse)


·

Displayed between 249 and 331 pulse (for LHD)

·

Displayed between 181 and 263 pulse (for RHD)

·

Air mix damper servo motor LH*1 or RH*2 system malfunction


Air Mix Servo Targ Pulse(P) Air mix damper servo motor RH*1 or LH*2 target pulse / Min.: 128, Max.:383
for LHD:
·

MAX COLD: 181 (pulse)

·

MAX HOT: 263 (pulse)


for RHD:
·

MAX COLD: 331 (pulse)

·

MAX HOT: 249 (pulse)


·

Displayed between 181 and 263 pulse (for LHD)

·

Displayed between 249 and 331 pulse (for RHD)

·

Air mix damper servo motor RH*1 or LH*2 system malfunction


Air Mix Servo Actual Pulse(P) Air mix damper servo motor RH*1 or LH*2 actual pulse / Min.: 128, Max.:383
for LHD:
·

MAX COLD: 181 (pulse)

·

MAX HOT: 263 (pulse)


for RHD:
·

MAX COLD: 331 (pulse)

·

MAX HOT: 249 (pulse)


·

Displayed between 181 and 263 pulse (for LHD)

·

Displayed between 249 and 331 pulse (for RHD)

·

Air mix damper servo motor RH*1 or LH*2 system malfunction


Air Outlet Servo Pulse (D) Mode damper servo motor LH*1 or RH*2 target pulse / Min.: 128, Max.:383
·

FACE: 254 (pulse)

·

FACE1: 246 (pulse)

·

FACE2: 254 (pulse)

·

B/L1: 230 (pulse)

·

B/L2: 218 (pulse)

·

FOOT-O: 208 (pulse)

·

FOOT-D: 189 (pulse)

·

FOOT-R: 178 (pulse)

·

FOOT-F: 178 (pulse)

·

FOOT 178 (pulse)

·

F/D: 155 (pulse)

·

DEF: 143 (pulse)


·

Displayed between 143 and 254 pulse

·

Mode damper servo motor LH*1 or RH*2 system malfunction


Air Outlet Servo Actu Pulse(D) Mode damper servo motor LH*1 or RH*2 actual pulse / Min.: 128, Max.:383
·

FACE: 254 (pulse)

·

FACE1: 246 (pulse)

·

FACE2: 254 (pulse)

·

B/L1: 230 (pulse)

·

B/L2: 218 (pulse)

·

FOOT-O: 208 (pulse)

·

FOOT-D: 189 (pulse)

·

FOOT-R: 178 (pulse)

·

FOOT-F: 178 (pulse)

·

FOOT 178 (pulse)

·

F/D: 155 (pulse)

·

DEF: 143 (pulse)


·

Displayed between 143 and 254 pulse

·

Mode damper servo motor LH*1 or RH*2 system malfunction


Air Outlet Servo Targ Pulse(P) Mode damper servo motor RH*1 or LH*2 target pulse / Min.: 128, Max.:383
for LHD:
·

FACE: 254 (pulse)

·

FACE1: 246 (pulse)

·

FACE2: 254 (pulse)

·

B/L1: 230 (pulse)

·

B/L2: 218 (pulse)

·

FOOT-O: 208 (pulse)

·

FOOT-D: 189 (pulse)

·

FOOT-R: 178 (pulse)

·

FOOT-F: 178 (pulse)

·

FOOT 178 (pulse)

·

F/D: 155 (pulse)

·

DEF: 143 (pulse)


for RHD:
·

FACE: 258 (pulse)

·

FACE1: 266 (pulse)

·

FACE2: 258 (pulse)

·

B/L1: 282 (pulse)

·

B/L2: 294 (pulse)

·

FOOT-O: 304 (pulse)

·

FOOT-D: 323 (pulse)

·

FOOT-R: 334 (pulse)

·

FOOT-F: 334 (pulse)

·

FOOT 334 (pulse)

·

F/D: 357 (pulse)

·

DEF: 369 (pulse)


·

Displayed between 143 and 254 pulse (for LHD)

·

Displayed between 258 and 369 pulse (for RHD)

·

Mode damper servo motor RH*1 or LH*2 system malfunction


Air Outlet Servo Actu Pulse(P) Mode damper servo motor RH*1 or LH*2 actual pulse / Min.: 128, Max.:383
for LHD:
·

FACE: 254 (pulse)

·

FACE1: 246 (pulse)

·

FACE2: 254 (pulse)

·

B/L1: 230 (pulse)

·

B/L2: 218 (pulse)

·

FOOT-O: 208 (pulse)

·

FOOT-D: 189 (pulse)

·

FOOT-R: 178 (pulse)

·

FOOT-F: 178 (pulse)

·

FOOT 178 (pulse)

·

F/D: 155 (pulse)

·

DEF: 143 (pulse)


for RHD:
·

FACE: 258 (pulse)

·

FACE1: 266 (pulse)

·

FACE2: 258 (pulse)

·

B/L1: 282 (pulse)

·

B/L2: 294 (pulse)

·

FOOT-O: 304 (pulse)

·

FOOT-D: 323 (pulse)

·

FOOT-R: 334 (pulse)

·

FOOT-F: 334 (pulse)

·

FOOT 334 (pulse)

·

F/D: 357 (pulse)

·

DEF: 369 (pulse)


·

Displayed between 143 and 254 pulse (for LHD)

·

Displayed between 258 and 369 pulse (for RHD)

·

Mode damper servo motor RH*1 or LH*2 system malfunction


Air Inlet Damper Targ Pulse Mode damper servo motor (REC/FRS) target pulse / Min.: 128, Max.:383
for LHD:
·

RECIRCULATION: 286 (pulse)

·

FRESH: 258 (pulse)


for RHD:
·

RECIRCULATION: 258 (pulse)

·

FRESH: 286 (pulse)


·

Displayed between 258 and 286 pulse

·

Mode damper servo motor (REC/FRS) system malfunction


Air Inlet Damper Actual Pulse Mode damper servo motor (REC/FRS) actual pulse / Min.: 128, Max.:383
for LHD:
·

RECIRCULATION: 286 (pulse)

·

FRESH: 258 (pulse)


for RHD:
·

RECIRCULATION: 258 (pulse)

·

FRESH: 286 (pulse)


·

Displayed between 258 and 286 pulse

·

Mode damper servo motor (REC/FRS) system malfunction


Cool Air Bypass Pulse Cool air bypass damper servo motor target pulse / Min.: 128, Max.:383
·

Shut: 225 (pulse)

·

Open: 254 (pulse)


·

Displayed between 258 and 286 pulse

·

Cool air bypass damper servo motor) system malfunction


Cool Air Bypass Actual Pulse Cool air bypass damper servo motor actual pulse / Min.: 128, Max.:383
·

Shut: 225 (pulse)

·

Open: 254 (pulse)


·

Displayed between 258 and 286 pulse

·

Cool air bypass damper servo motor) system malfunction


Electric Heater Count Electric heater count /
Min.: 0, Max.: 3
Maximum possible operation of electric heater displayed PTC heater system malfunction
Electric Heater Active Level Actual electric heater operation level Actual operation level of electric heater displayed PTC heater system malfunction
Shift Set Temperature Shift set temperature / +2 C, +1 C, NORMAL, -1 C, -2 C Customized value displayed -
Air Inlet Mode Air inlet mode / AUTO, MANUAL Customized value displayed -
Compressor Mode Compressor mode / AUTO, MANUAL Customized value displayed -
Add Foot Air in Face Mode Additional amount of air blow to the foot area / ON, OFF Customized value displayed -
ECO MODE Cancel ECO mode cancel / ON. OFF Customized value displayed w/ ECO Mode Switch
ECO Switch Integration control and panel assembly / OFF, ON ON: Integration control and panel assembly being turned and held at ECO position
OFF: integration control and panel assembly not turned
w/ ECO Mode Switch
Refrigerant Shortage Check Refrigerant gas volume check / ON, OFF Customized value displayed -
Fan speed increment control Blower with fan motor sub-assembly speed / Slow, Normal, ,Fast Customized value displayed -
Foot/DEF Auto Moden Foot/DEF auto mode / ON, OFF Customized value displayed -
Foot/DEF Automatic Blow Up Function Foot/DEF auto blower speed increase / ON, OFF Customized value displayed -
Ambient Temperature Shift Ambient temperature shift / +3 C, +2 C, +1 C, NORMAL, -1 C, -2 C, -3 C Customized value displayed -
Air Mix Servo Targ Pls(F&R D) Air mix damper servo motor (rear LH*1 or RH*2) target pulse / Min.: 128, Max.:383
for LHD:
·

MAX COLD: 262 (pulse)

·

MAX HOT: 290 (pulse)


for RHD:
·

MAX COLD: 250 (pulse)

·

MAX HOT: 222 (pulse)


·

Displayed between 262 and 290 pulse (for LHD)

·

Displayed between 222 and 250 pulse (for RHD)

·

Air mix damper servo motor (rear LH*1 or RH*2) system malfunction

·

w/ Rear Heater


A/M Servo Actual Pulse(F&R D) Air mix damper servo motor (rear LH*1 or RH*2) actual pulse / Min.: 128, Max.:383
for LHD:
·

MAX COLD: 262 (pulse)

·

MAX HOT: 290 (pulse)


for RHD:
·

MAX COLD: 250 (pulse)

·

MAX HOT: 222 (pulse)


·

Displayed between 262 and 290 pulse (for LHD)

·

Displayed between 222 and 250 pulse (for RHD)

·

Air mix damper servo motor (rear LH*1 or RH*2) system malfunction

·

w/ Rear Heater


Air Mix Servo Targ Pls(F&R P) Air mix damper servo motor (rear RH*1 or LH*2) target pulse / Min.: 128, Max.:383
for LHD:
·

MAX COLD: 250 (pulse)

·

MAX HOT: 222 (pulse)


for RHD:
·

MAX COLD: 262 (pulse)

·

MAX HOT: 290 (pulse)


·

Displayed between 222 and 250 pulse (for LHD)

·

Displayed between 262 and 290 pulse (for RHD)

·

Air mix damper servo motor (rear RH*1 or LH*2) system malfunction

·

w/ Rear Heater


A/M Servo Actual Pulse(F&R P) Air mix damper servo motor (rear RH*1 or LH*2) actual pulse / Min.: 128, Max.:383
for LHD:
·

MAX COLD: 250 (pulse)

·

MAX HOT: 222 (pulse)


for RHD:
·

MAX COLD: 262 (pulse)

·

MAX HOT: 290 (pulse)


·

Displayed between 222 and 250 pulse (for LHD)

·

Displayed between 262 and 290 pulse (for RHD)

·

Air mix damper servo motor (rear RH*1 or LH*2) system malfunction

·

w/ Rear Heater


Air Outlet Servo Pls (F&R D) Mode damper servo motor (rear) target pulse / Min.: 128, Max.: 383
·

FACE1: 258 (pulse)

·

FACE2: 258 (pulse)

·

B/L1: 277 (pulse)

·

FOOT-O: 290 (pulse)

·

FOOT-D: 290 (pulse)

·

FOOT-R: 290 (pulse)

·

FOOT-F: 307 (pulse)

·

F/D: 316 (pulse)

·

DEF: 328 (pulse)


·

Displayed between 258 and 328 pulse

·

Mode damper servo motor (rear) system malfunction


A/O Servo Actual PIse(F&R D) Mode damper servo motor (rear) actual pulse / Min.: 128, Max.: 383
·

FACE1: 258 (pulse)

·

FACE2: 258 (pulse)

·

B/L1: 277 (pulse)

·

FOOT-O: 290 (pulse)

·

FOOT-D: 290 (pulse)

·

FOOT-R: 290 (pulse)

·

FOOT-F: 307 (pulse)

·

F/D: 316 (pulse)

·

DEF: 328 (pulse)


·

Displayed between 258 and 328 pulse

·

Mode damper servo motor (rear) system malfunction


Room Temperature Sensor (RP) Rear room temperature sensor RH / Min.: -6.5°C (20.3°F), Max.: 57.25°C (135.05°F) Actual rear room temperature for RH seat displayed Rear room temperature sensor RH system malfunction:
·

Open in the circuit: -6.5°C (20.3°F)

·

Short in the circuit: 57.25°C (135.05°F)


Estimated Temperature (Rear D side) Rear driver side set temperature / MAX COLD: 17.5°C (63.5°F), MAX HOT: 32.5°C (90.5°F) Rear driver side actual set temperature displayed No. 2 air conditioning assembly system malfunction
Estimated Temperature (Rear P side) Rear passenger side set temperature / MAX COLD: 17.5°C (63.5°F), MAX HOT: 32.5°C (90.5°F) Rear passenger side actual set temperature displayed No. 2 air conditioning assembly system malfunction
A/O Damper DEF Pos(D side) DEF mode damper servo motor target pulse / Min.: 128, Max.: 383
·

FACE1: 258 (pulse)

·

FACE2: 258 (pulse)

·

B/L1: 277 (pulse)

·

FOOT-O: 290 (pulse)

·

FOOT-D: 290 (pulse)

·

FOOT-R: 290 (pulse)

·

FOOT-F: 307 (pulse)

·

F/D: 316 (pulse)

·

DEF: 328 (pulse)


·

Displayed between 258 and 328 pulse

·

DEF mode damper servo motor system malfunction

·

w/ Rear Heater*2


A/O Damper DEF Actual Pos(D) DEF mode damper servo motor actual pulse / Min.: 128, Max.: 383
·

FACE1: 258 (pulse)

·

FACE2: 258 (pulse)

·

B/L1: 277 (pulse)

·

FOOT-O: 290 (pulse)

·

FOOT-D: 290 (pulse)

·

FOOT-R: 290 (pulse)

·

FOOT-F: 307 (pulse)

·

F/D: 316 (pulse)

·

DEF: 328 (pulse)


·

Displayed between 258 and 328 pulse

·

DEF mode damper servo motor system malfunction

·

w/ Rear Heater*2


A/M Servo Targ Pulse(Rear P) Rear air mix damper servo motor RH*1 or LH*2 target pulse / Min.: 128, Max.: 383
for LHD:
·

MAX COLD: 258 (pulse)

·

MAX HOT: 213 (pulse)


for RHD:
·

MAX COLD: 254 (pulse)

·

MAX HOT: 299 (pulse)


·

Displayed between 213 and 258 pulse (for LHD)

·

Displayed between 254 and 299 pulse (for RHD)

·

Rear air mix damper servo motor RH*1 or LH*2 system malfunction

·

w/ Rear Heater


A/M Servo Actual Pulse (Rear P) Rear air mix damper servo motor RH actual pulse / Min.: 128, Max.: 383
for LHD:
·

MAX COLD: 258 (pulse)

·

MAX HOT: 213 (pulse)


for RHD:
·

MAX COLD: 254 (pulse)

·

MAX HOT: 299 (pulse)


·

Displayed between 213 and 258 pulse (for LHD)

·

Displayed between 254 and 299 pulse (for RHD)

·

Rear air mix damper servo motor RH*1 or LH*2 system malfunction

·

w/ Rear Heater


Foot Duct Sensor (Rear D) Air duct temperature sensor LH*1 or RH*2 / Min.: -12.7°C (9.14°F), Max.: 76.55°C (169.79°F) Cooler thermistor (duct sensor LH*1 or RH*2) displayed Cooler thermistor (duct sensor LH*1 or RH*2) system malfunction:
·

Open in the circuit: -12.7°C (9.14°F)

·

Short in the circuit: 76.55°C (169.79°F


Foot Duct Sensor (Rear P) Air duct temperature sensor RH*1 or LH*2 / Min.: -12.7°C (9.14°F), Max.: 76.55°C (169.79°F) Cooler thermistor (duct sensor RH*1 or LH*2) displayed Cooler thermistor (duct sensor RH*1 or LH*2) system malfunction:
·

Open in the circuit: -12.7°C (9.14°F)

·

Short in the circuit: 76.55°C (169.79°F


IDLE UP/PWR HEAT Switch Idle up switch / ON, OFF ON: Idle up switch on
OFF: Idle up switch off
w/ Viscous Heater
Refrigerant Gas Type Refrigerant gas type / R134a or 1234yf Refrigerant gas type displayed -
Number of Trouble Codes Number of trouble codes / Min.: 0, Max.: 255 Number of DTCs displayed -

*1: for LHD

*2: for RHD


Engine
Tester Display Measurement Item/Range Normal Condition Diagnostic Note
A/C Signal A/C signal / ON or OFF ON: A/C Switch on
OFF: A/C Switch off
-



ACTIVE TEST


HINT:

Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Body / Air Conditioner / Active Test.


e.

According to the display on the GTS, perform the Active Test.

Air Conditioner
Tester Display Test Part Control Range Diagnostic Note
Blower Motor Blower motor Min.: 0, Max.: 31 -
Heater Active Level Heater active level Min.: 0, Max.: 3 -
Magnetic Clutch Relay Magnetic clutch relay ON or OFF -
Air Mix Servo Targ Pulse(D) Air mix damper servo motor LH*1 or RH*2 pulse Min.: 128, Max.: 383
·

Operates between 249 to 331 (for LHD)

·

Operates between 181 to 263 (for RHD)


Air Mix Servo Targ Pulse(P) Air mix damper servo motor RH*1 or LH*2 pulse Min.: 128, Max.: 383
·

Operates between 181 to 263 (for LHD)

·

Operates between 249 to 331 (for RHD)


Air Outlet Servo Pulse (D) Mode damper servo motor LH Pulse Min.: 128, Max.: 383 Operates between 143 to 254
Air Inlet Damper Targ Pulse Mode damper servo motor (REC/FRS) pulse Min.: 128, Max.: 383 Operates between 258 to 286
Cool Air Bypass Pulse Cool air bypass damper servo motor pulse Min.: 128, Max.: 383 Operates between 225 to 254
Rear Blower Motor Rear blower motor Min.: 0, Max.: 31 -
Rear Air Mix Servo Targ Pulse Rear air mix damper servo motor LH*1 or RH*2 Pulse Min.: 128, Max.: 383
·

Operates between 254 to 299 (for LHD)

·

Operates between 213 to 258 (for RHD)

·

w/ Rear Heater


Rear A/C Mag Valve Rear air conditioning magnetic valve ON or OFF -
Air Outlet Servo Pulse (P) Mode damper servo motor RH*1 or LH*2 pulse Min.: 128, Max.: 383
·

Operates between 143 to 254 (for LHD)

·

Operates between 258 to 369 (for RHD)


A/M Servo Puls(F&R D) Air mix damper servo motor (rear LH*1 or RH*2) pulse Min.: 128, Max.: 383
·

Operates between 262 to 290 (for LHD)

·

Operates between 222 to 250 (for RHD)

·

w/ Rear Heater


A/M Servo Puls(F&R P) Air mix damper servo motor (rear RH*1 or LH*2) pulse Min.: 128, Max.: 383
·

Operates between 222 to 250 (for LHD)

·

Operates between 262 to 290 (for RHD)


A/O Servo Pulse(F&R D) Mode damper servo motor (rear) pulse Min.: 128, Max.: 383 Operates between 258 to 328
A/O Servo Pulse(Rr D) Rear mode damper servo motor pulse Min.: 128, Max.: 383 Operates between 200 to 276
DEF A/O Servo Pulse(D) DEF mode damper servo motor pulse Min.: 128, Max.: 383
·

Operates between 258 to 328

·

w/ Rear Heater*2


Rear A/M Servo Pulse(P) Rear air mix damper servo motor RH*1 or LH*2 pulse Min.: 128, Max.: 383
·

Operates between 213 to 258 (for LHD)

·

Operates between 254 to 299 (for RHD)

·

w/ Rear Heater



*1: for LHD

*2: for RHD