Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM(for Manual Air Conditioning System) › from 2015.08
RM2660E _58 Vehicle Interior _052847 HEATING / AIR CONDITIONING _0255703 AIR CONDITIONING SYSTEM(for Manual Air Conditioning System) U

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Manual Air Conditioning System)  DATA LIST / ACTIVE TEST  


HINT:

Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


DATA LIST


a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Data List.


e.

Enter the following menus: Powertrain / Engine and ECT / Data List.


f.

According to the display on the GTS, read the Data List.

Air Conditioner
Tester Display Measurement Item/Range Normal Condition Diagnostic Note
Ambient Temp Sensor Cooler thermistor (ambient temperature sensor) / Min.: -23.3°C (-9.94°F), Max.: 65.95°C (150.71°F) Actual ambient temperature displayed Thermistor assembly (ambient temperature sensor) system malfunction:
·

Open in the circuit: -23.3°C (-9.94°F)

·

Short in the circuit: 65.95°C (150.71°F)


Adjusted Ambient Temp Adjusted ambient temperature /Min.: -30.8°C (-23.44°F), Max.: 50.8°C (123.44°F) Adjusted ambient temperature displayed Air conditioning amplifier assembly
Evaporator Fin Thermistor No. 1 cooler thermistor (evaporator temperature sensor) / Min.: -29.7°C (-21.46°F), Max.: 59.55°C (139.19°F) Actual evaporator temperature displayed No. 1 cooler thermistor (evaporator temperature sensor) system malfunction:
·

Open in the circuit: -29.7°C (-21.46°F)

·

Short in the circuit: 59.55°C (139.19°F)


Engine Coolant Temp Engine coolant temperature / Min.: 1.3°C (34.34°F), Max.: 90.55°C (194.99°F) Actual engine coolant temperature displayed while engine warmed up
·

SFI system malfunction

·

CAN communication system malfunction


Blower Motor Speed Level Blower with fan motor sub-assembly speed level / Min.: 0 level, Max.: 31 level Displayed speed level increases in range between 0 and 31 as blower with fan motor subassembly speed increases Displayed speed level increases in range between 0 and 31 as blower with fan motor subassembly speed increases
Regulator Pressure Sensor Air conditioner pressure sensor / Min.: 0.4566 MPa, Max.: 3.2943 MPa Actual refrigerant pressure displayed
·

Air conditioning system (leaks, blocked)

·

Air conditioner pressure sensor system malfunction


Air Mix Servo Targ Pulse(D) Rear air mix damper servo motor target pulse / Min.: 128, Max.:383
for LHD:
·

MAX COLD: 254 (pulse)

·

MAX HOT: 299 (pulse)


for RHD:
·

MAX COLD: 258 (pulse)

·

MAX HOT: 213 (pulse)


·

Displayed between 254 and 299 pulse (for LHD)

·

Displayed between 213 and 258 pulse (for RHD)

·

Air mix damper servo motor system malfunction


Air Mix Servo Actual Pulse(D) Air mix damper servo motor actual pulse / Min.: 128, Max.:383
for LHD:
·

MAX COLD: 254 (pulse)

·

MAX HOT: 299 (pulse)


for RHD:
·

MAX COLD: 258 (pulse)

·

MAX HOT: 213 (pulse)


·

Displayed between 254 and 299 pulse (for LHD)

·

Displayed between 213 and 258 pulse (for RHD)

·

Air mix damper servo motor system malfunction


Air Outlet Servo Pulse (D) Mode damper servo motor target pulse / Min.: 128, Max.:383
·

FACE: 254 (pulse)

·

FACE1: 246 (pulse)

·

FACE2: 254 (pulse)

·

B/L1: 230 (pulse)

·

B/L2: 218 (pulse)

·

FOOT-O: 208 (pulse)

·

FOOT-D: 189 (pulse)

·

FOOT-R: 178 (pulse)

·

FOOT-F: 178 (pulse)

·

FOOT 178 (pulse)

·

F/D: 155 (pulse)

·

DEF: 143 (pulse)


·

Displayed between 143 and 254 pulse

·

Mode damper servo motor system malfunction


Air Outlet Servo Actu Pulse(D) Mode damper servo motor actual pulse / Min.: 128, Max.:383
·

FACE: 254 (pulse)

·

FACE1: 246 (pulse)

·

FACE2: 254 (pulse)

·

B/L1: 230 (pulse)

·

B/L2: 218 (pulse)

·

FOOT-O: 208 (pulse)

·

FOOT-D: 189 (pulse)

·

FOOT-R: 178 (pulse)

·

FOOT-F: 178 (pulse)

·

FOOT 178 (pulse)

·

F/D: 155 (pulse)

·

DEF: 143 (pulse)


·

Displayed between 143 and 254 pulse

·

Mode damper servo motor system malfunction


Air Inlet Damper Targ Pulse Mode damper servo motor (REC/FRS) target pulse / Min.: 128, Max.:383
for LHD:
·

RECIRCULATION: 286 (pulse)

·

FRESH: 258 (pulse)


for RHD:
·

RECIRCULATION: 258 (pulse)

·

FRESH: 286 (pulse)


·

Displayed between 258 and 286 pulse

·

Mode damper servo motor (REC/FRS) system malfunction


Air Inlet Damper Actual Pulse Mode damper servo motor (REC/FRS) actual pulse / Min.: 128, Max.:383
for LHD:
·

RECIRCULATION: 286 (pulse)

·

FRESH: 258 (pulse)


for RHD:
·

RECIRCULATION: 258 (pulse)

·

FRESH: 286 (pulse)


·

Displayed between 258 and 286 pulse

·

Mode damper servo motor (REC/FRS) system malfunction


Cool Air Bypass Pulse Cool air bypass damper servo motor target pulse / Min.: 128, Max.:383
·

Shut: 225 (pulse)

·

Open: 254 (pulse)


·

Displayed between 258 and 286 pulse

·

Cool air bypass damper servo motor) system malfunction


Cool Air Bypass Actual Pulse Cool air bypass damper servo motor actual pulse / Min.: 128, Max.:383
·

Shut: 225 (pulse)

·

Open: 254 (pulse)


·

Displayed between 258 and 286 pulse

·

Cool air bypass damper servo motor) system malfunction


Electric Heater Count Electric heater count /
Min.: 0, Max.: 3
Maximum possible operation of electric heater displayed PTC heater system malfunction
Electric Heater Active Level Actual electric heater operation level Actual operation level of electric heater displayed PTC heater system malfunction
Refrigerant Shortage Check Refrigerant gas volume check / ON, OFF Customized value displayed -
IDLE UP/PWR HEAT Switch Idle up switch / ON, OFF ON: Idle up switch on
OFF: Idle up switch off
w/ Viscous Heater
Refrigerant Gas Type Refrigerant gas type / R134a or 1234yf Refrigerant gas type displayed -
Number of Trouble Codes Number of trouble codes / Min.: 0, Max.: 255 Number of DTCs displayed -

Engine
Tester Display Measurement Item/Range Normal Condition Diagnostic Note
A/C Signal A/C signal / ON or OFF ON: A/C Switch on
OFF: A/C Switch off
-



ACTIVE TEST


HINT:

Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Active Test.


e.

According to the display on the GTS, perform the Active Test.

Air Conditioner
Tester Display Test Part Control Range Diagnostic Note
Blower Motor Blower motor Min.: 0, Max.: 31 -
Heater Active Level Heater active level Min.: 0, Max.: 3 -
Magnetic Clutch Relay Magnetic clutch relay ON or OFF -
Air Mix Servo Targ Pulse(D) Air mix damper servo motor pulse Min.: 128, Max.: 383
·

Operates between 249 to 331 (for LHD)

·

Operates between 181 to 263 (for RHD)


Air Outlet Servo Pulse (D) Mode damper servo motor Pulse Min.: 128, Max.: 383 Operates between 143 to 254
Air Inlet Damper Targ Pulse Mode damper servo motor (REC/FRS) pulse Min.: 128, Max.: 383 Operates between 258 to 286
Cool Air Bypass Pulse Cool air bypass damper servo motor pulse Min.: 128, Max.: 383 Operates between 225 to 254