Home › Vehicle Exterior › WINDOW / GLASS › POWER WINDOW CONTROL SYSTEM(for Models with Jam Protection Function on Driver Door Window Only) › 2014.08–2015.08
RM2660E _59 Vehicle Exterior _052850 WINDOW / GLASS _0255735 POWER WINDOW CONTROL SYSTEM(for Models with Jam Protection Function on Driver Door Window Only) U

WINDOW / GLASS  POWER WINDOW CONTROL SYSTEM(for Models with Jam Protection Function on Driver Door Window Only)  FAIL-SAFE CHART  


POWER WINDOW OPERATION IN FAIL-SAFE MODE


HINT:

If the pulse sensor built into the power window regulator motor malfunctions, the power window control system enters fail-safe mode.


a.

The pulse sensor for the jam protection function has problems and the window position or the learned value is abnormal.

HINT:

The power window control system prohibits the following power window operations when the pulse sensor for the jam protection function has problems and the window position or the learned value is abnormal.


Multiplex Network Master Switch
Power Window Operation Condition
Ignition Switch ON Ignition Switch off
(Key-off operation permitted)
Ignition Switch off
(Key-off operation prohibited)
Manual up (Driver side door window) X X -
Manual down (Driver side door window) ○*1 X -
Auto up (Driver side door window)
(hold switch at auto up position)
○*2 X -
Auto up (Driver side door window) X X -
Auto down (Driver side door window) X X -
Manual up (Remote switch operation) X X -
Manual down (Remote switch operation) X X -
Auto up (Remote switch operation)
(hold switch at auto up position)
X X -
Auto up (Remote switch operation) X X -
Auto down (Remote switch operation) X X -

HINT:

○: Operative

X: Operation prohibited

*1: Jam protection not operative

*2: In manual mode and jam protection not operative



i.

Power window switch LED control

HINT:

During normal operation (fail-safe is not operating), or during fail-safe mode when there is a pulse sensor malfunction or the window position or learned value is abnormal, the LED illuminates as shown in the illustration.


1.

for driver side:

U163943E01
0.681,1.589 1.532,1.965 0.851,0.375 10 Key-off operation: 1.724,2.119 2.411,2.300 0.687,0.181 10 Prohibition 1.669,1.63 2.411,1.811 0.742,0.181 10 Permission 0.668,3.534 1.852,3.909 1.184,0.375 10 Window lock switch signal: 2.231,3.993 2.445,4.173 0.214,0.181 10 0 2.231,3.504 2.445,3.685 0.214,0.181 10 1 0.668,2.633 1.037,2.843 0.369,0.210 10 LED: 1.836,3.114 2.491,3.296 0.655,0.181 10 Turns off 1.816,2.626 2.412,2.807 0.596,0.181 10 Turns on 0.66,0.604 1.617,0.814 0.957,0.210 10 Ignition switch: 2.162,1.133 2.408,1.315 0.246,0.181 10 Off 2.182,0.645 2.413,0.826 0.231,0.181 10 ON 4.183,0.788 5.053,0.788 false 5.368,0.064 6.783,0.276 1.415,0.211 10 Approximately 45 sec. 0.223,0.074 2.180,0.271 1.958,0.198 12 Normal output pattern: 4.574,0.788 5.138,0.158 5.138,0.158 5.303,0.158 false



ii.

Fail-safe Deactivation Condition

When the pulse sensor is normal, to deactivate fail-safe mode, pull up the power window switch to the auto up position and hold it for at least 1 second to fully close the window from the fully open position. As a result, the auto up/down function will return.




b.

Initialization failure

HINT:

During initialization of the power window regulator motor ECU, when the window position or initialization complete status cannot be properly read from the EEPROM, the power window control system prohibits the following operations.


Multiplex Network Master Switch
Power Window Operation Condition
Ignition Switch ON Ignition Switch off
(Key-off operation permitted)
Ignition Switch off
(Key-off operation prohibited)
Manual up (Driver side door window) X X -
Manual down (Driver side door window) ○*1 X -
Auto up (Driver side door window)
(hold switch at auto up position)
○*2 X -
Auto up (Driver side door window) X X -
Auto down (Driver side door window) X X -
Manual up (Remote switch operation) X X -
Manual down (Remote switch operation) X X -
Auto up (Remote switch operation)
(hold switch at auto up position)
X X -
Auto up (Remote switch operation) X X -
Auto down (Remote switch operation) X X -

HINT:

○: Operative

X: Operation prohibited

*1: Jam protection not operative

*2: In manual mode and jam protection not operative



i.

Power window switch LED control

HINT:

During initialization of the power window regulator motor ECU, when the window position or initialization complete status cannot be properly read from the EEPROM during fail-safe mode, the LED illuminates as shown in the illustration.


1.

for driver side:

U163944E01
0.724,3.562 1.686,3.937 0.961,0.375 10 Window lock switch signal: 2.287,4.021 2.501,4.201 0.214,0.181 10 0 2.287,3.532 2.501,3.713 0.214,0.181 10 1 0.724,1.693 1.093,1.903 0.369,0.210 10 LED: 1.849,2.175 2.503,2.356 0.655,0.181 10 Turns off 1.829,1.686 2.424,1.867 0.596,0.181 10 Turns on 0.732,0.632 1.690,0.842 0.958,0.210 10 Ignition switch: 2.295,1.161 2.527,1.343 0.232,0.181 10 Off 2.295,0.673 2.525,0.854 0.230,0.181 10 ON 0.181,0.102 2.734,0.299 2.553,0.198 12 Initialization failure output pattern: 3.131,2.177 3.131,3.296 false 3.275,2.176 3.275,2.553 false 3.42,2.176 3.42,2.904 false 4.007,2.174 4.007,3.315 false 3.575,2.174 3.575,3.315 false 2.581,3.074 3.084,3.074 false 3.962,3.074 3.628,3.074 false 3.575,3.074 3.131,3.074 false 2.581,2.717 3.084,2.717 false 3.546,2.717 3.471,2.717 false 2.581,2.355 3.084,2.355 false 3.399,2.355 3.324,2.355 false 3.278,2.355 3.13,2.355 false 4.066,3.463 4.584,3.657 0.518,0.194 10 1.5 sec. 2.59,3.102 3.108,3.297 0.518,0.194 10 1.5 sec. 2.59,2.745 3.108,2.939 0.518,0.194 10 1.0 sec. 2.59,2.382 3.108,2.576 0.518,0.194 10 0.5 sec. 3.42,2.716 3.131,2.716 false 4.053,3.545 3.968,3.545 3.968,3.545 3.765,3.074 false




c.

LIN communication failure

HINT:

If the LIN communication line malfunctions (communication stop), the power window control system prohibits the following operations.


Multiplex Network Master Switch
Power Window Operation Ignition Switch ON
Manual up ○*1
Manual down ○*2
Auto up (hold switch at auto up position) ○*1
Auto up ○*1
Auto down ○*2

HINT:

○: Operative

X: Operation prohibited

*1: Jam protection operative

*2: Jam protection not operative

Remote up/down function does not operate.




d.

LIN communication failure and pulse sensor failure

HINT:

If the LIN communication line malfunctions (communication stop) and the pulse sensor for the jam protection function has problems, the power window control system prohibits the following operations.


Multiplex Network Master Switch
Power Window Operation Always
Manual up X
Manual down X
Auto up (hold switch at auto up position) X
Auto up X
Auto down X

HINT:
·

○: Operative

·

X: Operation prohibited

·

Driver side door window: When there is no jam protection control due to a LIN communication failure, the manual up and auto up functions will not operate.

·

Remote switch operation: Not operative during LIN communication failure.




e.

LIN communication failure and window position, learned value abnormal or initialization failure

HINT:

If the LIN communication line malfunctions (communication stop) and the window position or the learned value is abnormal, the power window control system prohibits the following operations.


Multiplex Network Master Switch
Power Window Operation Always
Manual up ○*1
Manual down ○*2
Auto up (hold switch at auto up position) ○*1
Auto up -
Auto down -

HINT:
·

○: Operative

·

*1: Jam protection operative and window reverses direction upon reaching the fully closed position

·

*2: Jam protection not operative

·