69690
1.INSPECT BACK DOOR REMOTE CONTROL ASSEMBLY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 1 - 2 | Back door remote control is pulled (on) | Below 1 Ω |
| 1 - 2 | Back door remote control is not pulled (off) | 10 kΩ or higher |
If the result is not as specified, replace the back door remote control assembly.
| *a | Component without harness connected
(Back Door Remote Control Assembly) |
| *b | Not pulled (off) |
| *c | Pulled (on) |
69390A
2.INSPECT LOWER TAIL GATE LOCK ASSEMBLY LH
Operation check:
Set the lower tail gate lock LH to the full-latch position.
Apply battery voltage and check operation of the lower tail gate lock motor LH.
| Measurement Condition | Specified Condition |
|---|---|
| Battery positive (+) → Terminal 6 (ACT-)
Battery negative (-) → Terminal 5 (ACT+) |
Latch turns to open-latch position |
If the result is not as specified, replace the lower tail gate lock assembly LH.
Set the lower tail gate lock LH to the half-latch position.
Apply battery voltage and check operation of the lower tail gate lock motor LH.
| Measurement Condition | Specified Condition |
|---|---|
| Battery positive (+) → Terminal 5 (ACT+)
Battery negative (-) → Terminal 6 (ACT-) |
Latch turns to over-latch position |
If the result is not as specified, replace the lower tail gate lock assembly LH.
| *a | Component without harness connected
(Lower Tail Gate Lock Assembly LH) |
| *b | Over-latch |
| *c | Full-latch |
| *d | Half-latch |
| *e | Open-latch |
Resistance check:
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 7 (HND) - 8 (GND) | Over-latch | Below 1 Ω |
| 7 (HND) - 8 (GND) | Full-latch | 10 kΩ or higher |
| 7 (HND) - 8 (GND) | Half-latch | 10 kΩ or higher |
| 7 (HND) - 8 (GND) | Open-latch | 10 kΩ or higher |
If the result is not as specified, replace the lower tail gate lock assembly LH.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2 (FUL) - 3 (E1) | Over-latch | 10 kΩ or higher |
| 2 (FUL) - 3 (E1) | Full-latch | 10 kΩ or higher |
| 2 (FUL) - 3 (E1) | Half-latch | Below 1 Ω |
| 2 (FUL) - 3 (E1) | Open-latch | Below 1 Ω |
If the result is not as specified, replace the lower tail gate lock assembly LH.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (HAF) - 3 (E1) | Over-latch | 10 kΩ or higher |
| 1 (HAF) - 3 (E1) | Full-latch | Below 1 Ω |
| 1 (HAF) - 3 (E1) | Half-latch | 10 kΩ or higher |
| 1 (HAF) - 3 (E1) | Open-latch | Below 1 Ω |
If the result is not as specified, replace the lower tail gate lock assembly LH.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 4 (POL) - 3 (E1) | Over-latch | 10 kΩ or higher |
| 4 (POL) - 3 (E1) | Full-latch | Below 1 Ω |
| 4 (POL) - 3 (E1) | Half-latch | Below 1 Ω |
| 4 (POL) - 3 (E1) | Open-latch | 10 kΩ or higher |
If the result is not as specified, replace the lower tail gate lock assembly LH.
| *a | Component without harness connected
(Lower Tail Gate Lock Assembly LH) |
| *b | Over-latch |
| *c | Full-latch |
| *d | Half-latch |
| *e | Open-latch |
69380A
3.INSPECT LOWER TAIL GATE LOCK ASSEMBLY RH
Operation check:
Set the lower tail gate lock RH to the full-latch position.
Apply battery voltage and check operation of the lower tail gate lock motor RH.
| Measurement Condition | Specified Condition |
|---|---|
| Battery positive (+) → Terminal 6 (ACT-)
Battery negative (-) → Terminal 5 (ACT+) |
Latch turns to open-latch position |
If the result is not as specified, replace the lower tail gate lock assembly RH.
Set the lower tail gate lock RH to the half-latch position.
Apply battery voltage and check operation of the lower tail gate lock motor RH.
| Measurement Condition | Specified Condition |
|---|---|
| Battery positive (+) → Terminal 5 (ACT+)
Battery negative (-) → Terminal 6 (ACT-) |
Latch turns to over-latch position |
If the result is not as specified, replace the lower tail gate lock assembly RH.
| *a | Component without harness connected
(Lower Tail Gate Lock Assembly RH) |
| *b | Over-latch |
| *c | Full-latch |
| *d | Half-latch |
| *e | Open-latch |
Resistance check:
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 7 (HND) - 8 (GND) | Over-latch | Below 1 Ω |
| 7 (HND) - 8 (GND) | Full-latch | 10 kΩ or higher |
| 7 (HND) - 8 (GND) | Half-latch | 10 kΩ or higher |
| 7 (HND) - 8 (GND) | Open-latch | 10 kΩ or higher |
If the result is not as specified, replace the lower tail gate lock assembly RH.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2 (FUL) - 3 (E1) | Over-latch | 10 kΩ or higher |
| 2 (FUL) - 3 (E1) | Full-latch | 10 kΩ or higher |
| 2 (FUL) - 3 (E1) | Half-latch | Below 1 Ω |
| 2 (FUL) - 3 (E1) | Open-latch | Below 1 Ω |
If the result is not as specified, replace the lower tail gate lock assembly RH.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (HAF) - 3 (E1) | Over-latch | 10 kΩ or higher |
| 1 (HAF) - 3 (E1) | Full-latch | Below 1 Ω |
| 1 (HAF) - 3 (E1) | Half-latch | 10 kΩ or higher |
| 1 (HAF) - 3 (E1) | Open-latch | Below 1 Ω |
If the result is not as specified, replace the lower tail gate lock assembly RH.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 4 (POL) - 3 (E1) | Over-latch | 10 kΩ or higher |
| 4 (POL) - 3 (E1) | Full-latch | Below 1 Ω |
| 4 (POL) - 3 (E1) | Half-latch | Below 1 Ω |
| 4 (POL) - 3 (E1) | Open-latch | 10 kΩ or higher |
If the result is not as specified, replace the lower tail gate lock assembly RH.
| *a | Component without harness connected
(Lower Tail Gate Lock Assembly RH) |
| *b | Over-latch |
| *c | Full-latch |
| *d | Half-latch |
| *e | Open-latch |