This circuit detects the conditions of the headlight cleaner switch.
Headlight cleaner switch signal
Headlight operating signal
Daytime running light operating signal
Check that the headlights illuminate in LO beam.
Headlights illuminate in LO beam
OK
NG
Disconnect the G4 cleaner switch connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 8 (B) - 5 (L) | Headlight cleaner switch off | 10 kΩ or higher |
| 8 (B) - 5 (L) | Headlight cleaner switch on | Below 1 Ω |
OK
NG
Disconnect the headlight cleaner control relay connector.
Disconnect the G4 switch connector.
Disconnect the 2D main body ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2 (H) - G4-8 (B) | Always | Below 1 Ω |
| G4-5 (L) - 2D-23 (HRLY) | ||
| 2 (H) - Body ground | Always | 10 kΩ or higher |
| G4-8 (B) - Body ground | ||
| G4-5 (L) - Body ground | ||
| 2D-23 (HRLY) - Body ground |
OK
NG