Home › Engine / Hybrid System › 1UR-FE (ENGINE CONTROL) › SFI SYSTEM › from 2016.08
RM2660E _51 Engine / Hybrid System _052772 1UR-FE ENGINE CONTROL _0254983 SFI SYSTEM J

1UR-FE ENGINE CONTROL  SFI SYSTEM  ECM Power Source Circuit  


DESCRIPTION

When the engine switch is turned on (IG), the battery voltage is applied to the IGSW of the ECM. The output signal from the MREL terminal of the ECM causes a current to flow to the coil, closing the contacts of the integration relay (EFI MAIN NO. 1 relay) and supplying power to either terminal +B or +B2 of the ECM.

WIRING DIAGRAM

A383883E01
0.552,4.031 1.125,4.271 0.573,0.24 10 false Battery 0.396,2.698 0.969,2.938 0.573,0.24 10 false P/I-B 1.552,4.167 2.125,4.406 0.573,0.24 10 false IG1D 3.615,4.302 4.51,4.542 0.896,0.24 10 false *1: for RHD 1.344,4.813 3.083,5.354 1.74,0.542 10 false Certification ECU Assembly (Smart Key ECU Assembly) 3.625,4.625 4.521,4.865 0.896,0.24 10 false *2: for LHD 3.104,3.74 4.688,4.01 1.583,0.271 10 false No. 2 Integration Relay 6.396,4.833 6.906,5.115 0.51,0.281 10 false ECM 2.979,2.958 4.167,3.198 1.188,0.24 10 false EFI MAIN NO. 1 2.052,2.458 3.24,2.698 1.188,0.24 10 false EFI MAIN NO. 1 3.083,1.677 3.833,1.948 0.75,0.271 10 false IG2 MAIN 2.396,1.219 3.146,1.49 0.75,0.271 10 false IG2 MAIN 3.656,1.229 4.729,1.458 1.073,0.229 10 false ENG-IG2 NO. 1 1.396,1.031 1.646,1.25 0.25,0.219 10 false 1X 1.396,1.854 1.646,2.073 0.25,0.219 10 false 1R 4.594,1.031 4.844,1.25 0.25,0.219 10 false 1P 4.583,2.271 4.833,2.49 0.25,0.219 10 false 1S 4.583,2.708 4.833,2.927 0.25,0.219 10 false 1S 4.583,3.271 4.833,3.49 0.25,0.219 10 false 1S 5.396,1.042 5.646,1.26 0.25,0.219 10 false A52 5.385,1.708 5.635,1.927 0.25,0.219 10 false A52 5.385,2.281 5.635,2.5 0.25,0.219 10 false A52 5.385,3.271 5.635,3.49 0.25,0.219 10 false A52 5.781,1.042 6.031,1.26 0.25,0.219 10 false A38 5.781,1.698 6.031,1.917 0.25,0.219 10 false A38 5.771,2.281 6.021,2.5 0.25,0.219 10 false A38 5.771,3.271 6.021,3.49 0.25,0.219 10 false A38 5.385,4.271 5.635,4.49 0.25,0.219 10 false C46 5.771,4.281 6.021,4.5 0.25,0.219 10 false C45 6.146,4.271 6.396,4.49 0.25,0.219 10 false E1 6.146,3.156 6.583,3.375 0.438,0.219 10 false MREL 6.135,2.271 6.573,2.49 0.438,0.219 10 false +B2 6.146,1.698 6.583,1.917 0.438,0.219 10 false +B 6.146,0.927 6.583,1.146 0.438,0.219 10 false IGSW 5.375,0.833 5.729,1.042 0.354,0.208 10 false 28*1 5.75,0.833 6.104,1.042 0.354,0.208 10 false 28*2 5.406,1.5 5.708,1.708 0.302,0.208 10 false 3*1 5.771,1.5 6.073,1.708 0.302,0.208 10 false 3*2 5.406,2.083 5.708,2.292 0.302,0.208 10 false 2*1 5.792,2.083 6.094,2.292 0.302,0.208 10 false 2*2 5.375,3.063 5.677,3.271 0.302,0.208 10 false 34*1 5.75,3.063 6.052,3.271 0.302,0.208 10 false 34*2 5.375,4.063 5.677,4.271 0.302,0.208 10 false 81*1 5.75,4.063 6.052,4.271 0.302,0.208 10 false 81*2 4.635,3.083 4.885,3.302 0.25,0.219 10 false 8 4.625,2.51 4.875,2.729 0.25,0.219 10 false 4 4.594,2.073 4.844,2.292 0.25,0.219 10 false 11 4.625,0.833 4.875,1.052 0.25,0.219 10 false 7 1.427,0.823 1.677,1.042 0.25,0.219 10 false 1 1.438,1.646 1.688,1.865 0.25,0.219 10 false 2 1.344,4.01 1.594,4.229 0.25,0.219 10 false 3 1.354,4.635 1.927,4.875 0.573,0.24 10 false E128

CAUTION / NOTICE / HINT

NOTICE:

Inspect the fuses for circuits related to this system before performing the following inspection procedure.


PROCEDURE

1.INSPECT NO. 2 INTEGRATION RELAY (POWER SOURCE)
a.
A299433C17
0.49,1.021 0.906,1.313 0.417,0.292 0.625,1.104 0.938,1.302 0.313,0.198 10 false 1X 0.135,0.125 0.448,0.281 0.313,0.156 10 false *a
*a Front view of wire harness connector
(to No. 2 integration relay)


Disconnect the No. 2 integration relay connector.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
1X-1 - Body ground Always 11 to 14 V




OK

2.CHECK HARNESS AND CONNECTOR (NO. 2 INTEGRATION RELAY - BODY GROUND)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR (BATTERY - NO. 2 INTEGRATION RELAY)

2.CHECK HARNESS AND CONNECTOR (NO. 2 INTEGRATION RELAY - BODY GROUND)
a.

Disconnect the No. 2 integration relay connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1S-4 - Body ground Always Below 1 Ω




OK

3.INSPECT NO. 2 INTEGRATION RELAY (IG2 MAIN, EFI MAIN NO. 1)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.INSPECT NO. 2 INTEGRATION RELAY (IG2 MAIN, EFI MAIN NO. 1)
a.

Inspect the No. 2 integration relay (See page Engine / Hybrid System>1UR-FE (ENGINE CONTROL)>RELAY>ON-VEHICLE INSPECTION).



OK

4.CHECK HARNESS AND CONNECTOR (NO. 2 INTEGRATION RELAY - ECM)

NG

REPLACE NO. 2 INTEGRATION RELAY

4.CHECK HARNESS AND CONNECTOR (NO. 2 INTEGRATION RELAY - ECM)
a.

Disconnect the ECM connector.


b.

Disconnect the No. 2 integration relay connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance (for RHD):
Tester Connection Condition Specified Condition
A52-34 (MREL) - 1S-8 Always Below 1 Ω
A52-3 (+B) - 1S-11 Always Below 1 Ω
A52-2 (+B2) - 1S-11 Always Below 1 Ω
A52-34 (MREL) or 1S-8 - Body ground Always 10 kΩ or higher
A52-3 (+B) or 1S-11 - Body ground Always 10 kΩ or higher
A52-2 (+B2) or 1S-11 - Body ground Always 10 kΩ or higher


Standard Resistance (for LHD):
Tester Connection Condition Specified Condition
A38-34 (MREL) - 1S-8 Always Below 1 Ω
A38-3 (+B) - 1S-11 Always Below 1 Ω
A38-2 (+B2) - 1S-11 Always Below 1 Ω
A38-34 (MREL) or 1S-8 - Body ground Always 10 kΩ or higher
A38-3 (+B) or 1S-11 - Body ground Always 10 kΩ or higher
A38-2 (+B2) or 1S-11 - Body ground Always 10 kΩ or higher




OK

5.CHECK HARNESS AND CONNECTOR (ECM - BODY GROUND)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

5.CHECK HARNESS AND CONNECTOR (ECM - BODY GROUND)
a.

Disconnect the ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance (for RHD):
Tester Connection Condition Specified Condition
C46-81 (E1) - Body ground Always Below 1 Ω


Standard Resistance (for LHD):
Tester Connection Condition Specified Condition
C45-81 (E1) - Body ground Always Below 1 Ω




OK

6.INSPECT ECM (IGSW VOLTAGE)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

6.INSPECT ECM (IGSW VOLTAGE)
a.
U162916E01
2.141,1.736 1.994,1.077 false 1.04,0.989 1.811,1.193 0.772,0.204 10 28 (IGSW) 0.074,0.034 2.420,0.401 2.346,0.367 10 Front view of wire harness connector: (to ECM) 2.653,1.528 2.956,1.694 0.302,0.166 10 A52 2.653,1.904 2.956,2.069 0.302,0.166 10 A38 0.491,2.585 1.389,2.755 0.897,0.169 10 *1: for RHD 1.559,2.585 2.457,2.755 0.897,0.169 10 *2: for LHD 3.055,1.49 3.282,1.659 0.227,0.169 10 *1 3.055,1.866 3.282,2.035 0.227,0.169 10 *2 2.002,1.082 1.879,1.082 false

Disconnect the ECM connectors.


b.

Turn the engine switch on (IG).


c.

Measure the voltage according to the value(s) in the table below.

Standard Voltage (for RHD):
Tester Connection Switch Condition Specified Condition
A52-28 (IGSW) - Body ground Engine switch on (IG) 11 to 14 V


Standard Voltage (for LHD):
Tester Connection Switch Condition Specified Condition
A38-28 (IGSW) - Body ground Engine switch on (IG) 11 to 14 V




OK

NG

7.CHECK HARNESS AND CONNECTOR (NO. 2 INTEGRATION RELAY - ECM)
7.CHECK HARNESS AND CONNECTOR (NO. 2 INTEGRATION RELAY - ECM)
a.

Disconnect the ECM connector.


b.

Disconnect the No. 2 integration relay connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance (for RHD):
Tester Connection Condition Specified Condition
A52-28 (IGSW) - 1P-7 Always Below 1 Ω
A52-28 (IGSW) or 1P-7 - Body ground Always 10 kΩ or higher


Standard Resistance (for LHD):
Tester Connection Condition Specified Condition
A38-28 (IGSW) - 1P-7 Always Below 1 Ω
A38-28 (IGSW) or 1P-7 - Body ground Always 10 kΩ or higher




OK

8.CHECK HARNESS AND CONNECTOR (SMART KEY ECU ASSEMBLY - NO. 2 INTEGRATION RELAY)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

8.CHECK HARNESS AND CONNECTOR (SMART KEY ECU ASSEMBLY - NO. 2 INTEGRATION RELAY)
a.

Disconnect the smart key ECU assembly connector.


b.

Disconnect the No. 2 integration relay connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
E128-3 (IG1D) - 1R-2 Always Below 1 Ω
E128-3 (IG1D) or 1R-2 - Body ground Always 10 kΩ or higher




OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR