1.INSTALL PIPING CLAMP (for Engine Room Side)
Remove the vinyl tape from the No. 3 air conditioning tube and accessory assembly and cooler refrigerant liquid pipe A.
Sufficiently apply compressor oil to 2 new O-rings and the fitting surfaces of the No. 3 air conditioning tube and accessory assembly.
ND-OIL 8 or equivalent
Do not use any compressor oil other than ND-OIL 8 or equivalent. If any compressor oil other than ND-OIL 8 or equivalent is used, compressor motor insulation performance may decrease, resulting in leakage of electric power.
Install the 2 O-rings to the No. 3 air conditioning tube and accessory assembly.
Keep the O-rings and O-ring fitting surfaces free of foreign matter.
Install the No. 3 air conditioning tube and accessory assembly to the cooler refrigerant liquid pipe A.
Make sure not to cut the O-ring while installing it. (Cut O-rings cannot be installed.)
Check that the assemblies are securely engaged.
| *a | Correct |
| *b | Incorrect |
| *c | No Gap |
| *d | Gap |
Install the piping clamp to the No. 3 air conditioning tube and accessory assembly and cooler refrigerant liquid pipe A.
Make sure that the piping clamp is engaged securely with no gap.
2.INSTALL PIPING CLAMP (for Air Conditioning Unit Side)
3.CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT
4.WARM UP ENGINE
5.INSPECT FOR REFRIGERANT LEAK
53292A 6.INSTALL UPPER RADIATOR SUPPORT SEAL