DATA LIST
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
Air Conditioner
| Tester Display | Measurement Item | Range | Normal Condition | Inspection Item |
|---|---|---|---|---|
| Total Distance Traveled | Total distance traveled | 0 to 999999 | Total distance traveled | - |
| Total Distance Traveled - Unit | Total distance traveled unit | km / mile | - | - |
| Room Temperature Sensor | Cooler thermistor (room temperature sensor) | -327.68 to 327.67 °C | Actual cabin temperature displayed | Cooler thermistor (room temperature sensor) circuit malfunction |
| Ambient Temperature Sensor | Cooler thermistor (ambient temperature sensor) | -327.68 to 327.67 °C | Actual ambient temperature displayed | Cooler thermistor (ambient temperature sensor) circuit malfunction |
| Front Left Solar Sensor | Front left side automatic light control sensor | 0 to 6553.5 W/m2 | Front left side automatic light control sensor value increases as brightness increases | Automatic light control sensor circuit malfunction |
| Front Right Solar Sensor | Front right side automatic light control sensor | 0 to 6553.5 W/m2 | Front right side automatic light control sensor value increases as brightness increases | Automatic light control sensor circuit malfunction |
| Engine Coolant Temperature Sensor | Engine coolant temperature sensor | -327.68 to 327.67 °C | Actual engine coolant temperature displayed |
·
SFI system malfunction (Engine coolant temperature sensor circuit malfunction)
·
CAN communication system malfunction |
| Evaporator Fin Thermistor | No. 1 cooler thermistor | -327.68 to 327.67 °C | Actual evaporator temperature displayed | No. 1 cooler thermistor circuit malfunction |
| Regulator Pressure Sensor | Air conditioning pressure sensor | -32.768 to 32.767 MPaG | Actual refrigerant pressure displayed |
·
Refrigerant line (gas leak etc.)
·
Air conditioning pressure sensor circuit malfunction |
| Rear Evaporator Temperature Sensor | No. 2 cooler thermistor | -327.68 to 327.67 °C | Actual evaporator temperature displayed | No. 2 cooler thermistor circuit malfunction |
| Rear Left Room Temperature Sensor | Cooler thermistor (duct sensor) (for LH Side) | -327.68 to 327.67 °C | Actual cabin temperature displayed | Cooler thermistor (duct sensor) (for LH Side) circuit malfunction |
| Rear Right Room Temperature Sensor | Cooler thermistor (duct sensor) (for RH Side) | -327.68 to 327.67 °C | Actual cabin temperature displayed | Cooler thermistor (duct sensor) (for RH Side) circuit malfunction |
| Ambient Temperature Adjustment Value | Adjusted ambient temperature | -327.68 to 327.67 °C | Adjust ambient temperature displayed | Air conditioning amplifier assembly circuit malfunction |
| Front Right Air Outlet Temperature | Front right side target air outlet temperature | -327.68 to 327.67 °C | Front right side target air outlet temperature displayed
·
MAX COLD: -327.68°C
·
MAX HOT: 327.67°C |
- |
| Front Left Air Outlet Temperature | Front left side target air outlet temperature | -327.68 to 327.67 °C | Front left side target air outlet temperature displayed
·
MAX COLD: -327.68°C
·
MAX HOT: 327.67°C |
- |
| Rear Right Air Outlet Temperature | Rear right side target air outlet temperature | -327.68 to 327.67 °C | Rear left side target air outlet temperature displayed
·
MAX COLD: -327.68°C
·
MAX HOT: 327.67°C |
- |
| Rear Left Air Outlet Temperature | Rear left side target air outlet temperature | -327.68 to 327.67 °C | Rear right side target air outlet temperature displayed
·
MAX COLD: -327.68°C
·
MAX HOT: 327.67°C |
- |
| Evaporator Target Temperature | Evaporator target temperature | -327.68 to 327.67 °C | Evaporator target temperature displayed | No. 1 cooler thermistor circuit malfunction |
| Front Right Set Temperature | Front right side set temperature | MAX COLD / 14.0°C / 14.5°C / 15.0°C / 15.5°C / 16.0°C / 16.5°C / 17.0°C / 17.5°C / 18.0°C / 18.5°C / 19.0°C / 19.5°C / 20.0°C / 20.5°C / 21.0°C / 21.5°C / 22.0°C / 22.5°C / 23.0°C / 23.5°C / 24.0°C / 24.5°C / 25.0°C / 25.5°C / 26.0°C / 26.5°C / 27.0°C / 27.5°C / 28.0°C / 28.5°C / 29.0°C / 29.5°C / 30.0°C / 30.5°C / 31.0°C / 31.5°C / 32.0°C / MAX HOT | Front right side set temperature displayed | Air conditioning control assembly circuit malfunction |
| Front Left Set Temperature | Front left side set temperature | MAX COLD / 14.0°C / 14.5°C / 15.0°C / 15.5°C / 16.0°C / 16.5°C / 17.0°C / 17.5°C / 18.0°C / 18.5°C / 19.0°C / 19.5°C / 20.0°C / 20.5°C / 21.0°C / 21.5°C / 22.0°C / 22.5°C / 23.0°C / 23.5°C / 24.0°C / 24.5°C / 25.0°C / 25.5°C / 26.0°C / 26.5°C / 27.0°C / 27.5°C / 28.0°C / 28.5°C / 29.0°C / 29.5°C / 30.0°C / 30.5°C / 31.0°C / 31.5°C / 32.0°C / MAX HOT | Front left side set temperature displayed | Air conditioning control assembly circuit malfunction |
| Rear Right Set Temperature | Rear right side set temperature | MAX COLD / 14.0°C / 14.5°C / 15.0°C / 15.5°C / 16.0°C / 16.5°C / 17.0°C / 17.5°C / 18.0°C / 18.5°C / 19.0°C / 19.5°C / 20.0°C / 20.5°C / 21.0°C / 21.5°C / 22.0°C / 22.5°C / 23.0°C / 23.5°C / 24.0°C / 24.5°C / 25.0°C / 25.5°C / 26.0°C / 26.5°C / 27.0°C / 27.5°C / 28.0°C / 28.5°C / 29.0°C / 29.5°C / 30.0°C / 30.5°C / 31.0°C / 31.5°C / 32.0°C / MAX HOT | Rear right side set temperature displayed | Cooler control switch assembly circuit malfunction (w/ Rear Air Conditioning System) |
| Rear Left Set Temperature | Rear left side set temperature | MAX COLD / 14.0°C / 14.5°C / 15.0°C / 15.5°C / 16.0°C / 16.5°C / 17.0°C / 17.5°C / 18.0°C / 18.5°C / 19.0°C / 19.5°C / 20.0°C / 20.5°C / 21.0°C / 21.5°C / 22.0°C / 22.5°C / 23.0°C / 23.5°C / 24.0°C / 24.5°C / 25.0°C / 25.5°C / 26.0°C / 26.5°C / 27.0°C / 27.5°C / 28.0°C / 28.5°C / 29.0°C / 29.5°C / 30.0°C / 30.5°C / 31.0°C / 31.5°C / 32.0°C / MAX HOT | Rear left side set temperature displayed | Cooler control switch assembly circuit malfunction (w/ Rear Air Conditioning System) |
| Front Left Air Mix Damper Control Servo Motor Target Pulse | No. 2 air conditioning radiator damper servo sub-assembly target pulse | 128 to 384 |
·
MAX COLD: 254 (pulse)
·
MAX HOT: 326 (pulse) |
No. 2 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Front Left Air Mix Damper Control Servo Motor Actual Pulse | No. 2 air conditioning radiator damper servo sub-assembly actual pulse | 128 to 384 |
·
MAX COLD: 254 (pulse)
·
MAX HOT: 326 (pulse) |
No. 2 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Front Left Air Mix Cool Damper Control Servo Motor Target Pulse | No. 2 air conditioning radiator damper servo sub-assembly target pulse | 128 to 384 |
for Dual:
·
MAX COLD: 258 (pulse)
·
MAX HOT: 154 (pulse)
for 4 Zone:
·
MAX COLD: 254 (pulse)
·
MAX HOT: 358 (pulse) |
No. 2 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Front Left Air Mix Cool Damper Control Servo Motor Actual Pulse | No. 2 air conditioning radiator damper servo sub-assembly actual pulse | 128 to 384 |
for Dual:
·
MAX COLD: 258 (pulse)
·
MAX HOT: 154 (pulse)
for 4 Zone:
·
MAX COLD: 254 (pulse)
·
MAX HOT: 358 (pulse) |
No. 2 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Front Right Air Mix Damper Control Servo Motor Target Pulse | No. 4 air conditioning radiator damper servo sub-assembly target pulse | 128 to 384 |
·
MAX COLD: 258 (pulse)
·
MAX HOT: 186 (pulse) |
No. 4 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Front Right Air Mix Damper Control Servo Motor Actual Pulse | No. 4 air conditioning radiator damper servo sub-assembly actual pulse | 128 to 384 |
·
MAX COLD: 258 (pulse)
·
MAX HOT: 186 (pulse) |
No. 4 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Front Right Air Mix Cool Damper Control Servo Motor Target Pulse | No. 4 air conditioning radiator damper servo sub-assembly target pulse | 128 to 384 |
·
MAX COLD: 258 (pulse)
·
MAX HOT: 154 (pulse) |
No. 4 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Front Right Air Mix Cool Damper Control Servo Motor Actual Pulse | No. 4 air conditioning radiator damper servo sub-assembly actual pulse | 128 to 384 |
·
MAX COLD: 258 (pulse)
·
MAX HOT: 154 (pulse) |
No. 4 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Front Left Air Outlet Damper Control Servo Motor Target Pulse | No. 1 air conditioning radiator damper servo sub-assembly target pulse | 128 to 384 |
·
FACE1: 258 (pulse)
·
FACE2: 258 (pulse)
·
FACE: 313 (pulse)
·
B/L: 321 (pulse)
·
FOOT-0: 348 (pulse)
·
FOOT-D: 348 (pulse)
·
FOOT-R: 348 (pulse)
·
FOOT: 347 (pulse)
·
F/D: 302 (pulse)
·
DEF: 364 (pulse) |
No. 1 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Front Left Air Outlet Damper Control Servo Motor Actual Pulse | No. 1 air conditioning radiator damper servo sub-assembly actual pulse | 128 to 384 |
·
FACE1: 258 (pulse)
·
FACE2: 258 (pulse)
·
FACE: 313 (pulse)
·
B/L: 321 (pulse)
·
FOOT-0: 348 (pulse)
·
FOOT-D: 348 (pulse)
·
FOOT-R: 348 (pulse)
·
FOOT: 347 (pulse)
·
F/D: 302 (pulse)
·
DEF: 364 (pulse) |
No. 1 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Front Right Air Outlet Damper Control Servo Motor Target Pulse | No. 6 air conditioning radiator damper servo sub-assembly target pulse | 128 to 384 |
·
FACE1: 254 (pulse)
·
FACE2: 254 (pulse)
·
FACE: 199 (pulse)
·
B/L: 191 (pulse)
·
FOOT-0: 164 (pulse)
·
FOOT-D: 164 (pulse)
·
FOOT-R: 164 (pulse)
·
FOOT: 165 (pulse)
·
F/D: 210 (pulse)
·
DEF: 148 (pulse) |
No. 6 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Front Right Air Outlet Damper Control Servo Motor Actual Pulse | No. 6 air conditioning radiator damper servo sub-assembly actual pulse | 128 to 384 |
·
FACE1: 254 (pulse)
·
FACE2: 254 (pulse)
·
FACE: 199 (pulse)
·
B/L: 191 (pulse)
·
FOOT-0: 164 (pulse)
·
FOOT-D: 164 (pulse)
·
FOOT-R: 164 (pulse)
·
FOOT: 165 (pulse)
·
F/D: 210 (pulse)
·
DEF: 148 (pulse) |
No. 6 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Air Inlet Damper Control Servo Motor Target Pulse | No. 1 blower damper servo sub-assembly target pulse | 128 to 384 |
for LHD (Single Layer):
·
Fresh: 238 (pulse)
·
Recirculation: 258 (pulse)
for LHD (Double Layer):
·
Fresh: 290 (pulse)
·
Recirculation: 258 (pulse)
for RHD:
·
Fresh: 222 (pulse)
·
Recirculation: 254 (pulse) |
No. 1 blower damper servo sub-assembly circuit malfunction |
| Air Inlet Damper Control Servo Motor Actual Pulse | No. 1 blower damper servo sub-assembly actual pulse | 128 to 384 |
for LHD (Single Layer):
·
Fresh: 238 (pulse)
·
Recirculation: 258 (pulse)
for LHD (Double Layer):
·
Fresh: 290 (pulse)
·
Recirculation: 258 (pulse)
for RHD:
·
Fresh: 222 (pulse)
·
Recirculation: 254 (pulse) |
No. 1 blower damper servo sub-assembly circuit malfunction |
| Front DEF Air Outlet Damper Control Servo Motor Target Pulse | No. 5 air conditioning radiator damper servo sub-assembly target pulse | 128 to 384 |
·
FACE1: 348 (pulse)
·
FACE2: 348 (pulse)
·
FACE: 348 (pulse)
·
B/L: 348 (pulse)
·
FOOT-0: 348 (pulse)
·
FOOT-D: 326 (pulse)
·
FOOT-R: 333 (pulse)
·
FOOT: 329 (pulse)
·
F/D: 242 (pulse)
·
DEF: 242 (pulse) |
No. 5 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Front DEF Air Outlet Damper Control Servo Motor Actual Pulse | No. 5 air conditioning radiator damper servo sub-assembly actual pulse | 128 to 384 |
·
FACE1: 348 (pulse)
·
FACE2: 348 (pulse)
·
FACE: 348 (pulse)
·
B/L: 348 (pulse)
·
FOOT-0: 348 (pulse)
·
FOOT-D: 326 (pulse)
·
FOOT-R: 333 (pulse)
·
FOOT: 329 (pulse)
·
F/D: 242 (pulse)
·
DEF: 242 (pulse) |
No. 5 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Front Left FOOT/DEF Air Outlet Damper Control Servo Motor Target Pulse | No. 1 air conditioning radiator damper servo sub-assembly target pulse | 128 to 384 |
·
FACE1: 267 (pulse)
·
FACE2: 258 (pulse)
·
FACE: 283 (pulse)
·
B/L: 292 (pulse)
·
FOOT-0: 317 (pulse)
·
FOOT-D: 292 (pulse)
·
FOOT-R: 292 (pulse)
·
FOOT: 317 (pulse)
·
F/D: 328 (pulse)
·
DEF: 365 (pulse) |
No. 1 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Front Left FOOT/DEF Air Outlet Damper Control Servo Motor Actual Pulse | No. 1 air conditioning radiator damper servo sub-assembly actual pulse | 128 to 384 |
·
FACE1: 267 (pulse)
·
FACE2: 258 (pulse)
·
FACE: 283 (pulse)
·
B/L: 292 (pulse)
·
FOOT-0: 317 (pulse)
·
FOOT-D: 292 (pulse)
·
FOOT-R: 292 (pulse)
·
FOOT: 317 (pulse)
·
F/D: 328 (pulse)
·
DEF: 365 (pulse) |
No. 1 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Front Right FOOT/DEF Air Outlet Damper Control Servo Motor Target Pulse | No. 6 air conditioning radiator damper servo sub-assembly target pulse | 128 to 384 |
·
FACE1: 245 (pulse)
·
FACE2: 254 (pulse)
·
FACE: 229 (pulse)
·
B/L: 220 (pulse)
·
FOOT-0: 195 (pulse)
·
FOOT-D: 220 (pulse)
·
FOOT-R: 220 (pulse)
·
FOOT: 195 (pulse)
·
F/D: 184 (pulse)
·
DEF: 147 (pulse) |
No. 6 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Front Right FOOT/DEF Air Outlet Damper Control Servo Motor Actual Pulse | No. 6 air conditioning radiator damper servo sub-assembly actual pulse | 128 to 384 |
·
FACE1: 245 (pulse)
·
FACE2: 254 (pulse)
·
FACE: 229 (pulse)
·
B/L: 220 (pulse)
·
FOOT-0: 195 (pulse)
·
FOOT-D: 220 (pulse)
·
FOOT-R: 220 (pulse)
·
FOOT: 195 (pulse)
·
F/D: 184 (pulse)
·
DEF: 147 (pulse) |
No. 6 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Front Control Rear Left Air Mix Damper Control Servo Motor Target Pulse | No. 2 air conditioning radiator damper servo sub-assembly target pulse | 128 to 384 |
·
MAX COLD: 258 (pulse)
·
MAX HOT: 154 (pulse) |
No. 2 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Front Control Rear Left Air Mix Damper Control Servo Motor Actual Pulse | No. 2 air conditioning radiator damper servo sub-assembly actual pulse | 128 to 384 |
·
MAX COLD: 258 (pulse)
·
MAX HOT: 154 (pulse) |
No. 2 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Front Control Rear Right Air Mix Damper Control Servo Motor Target Pulse | No. 4 air conditioning radiator damper servo sub-assembly target pulse | 128 to 384 |
·
MAX COLD: 258 (pulse)
·
MAX HOT: 154 (pulse) |
No. 4 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Front Control Rear Right Air Mix Damper Control Servo Motor Actual Pulse | No. 4 air conditioning radiator damper servo sub-assembly actual pulse | 128 to 384 |
·
MAX COLD: 258 (pulse)
·
MAX HOT: 154 (pulse) |
No. 4 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Rear Left Air Mix Damper Control Servo Motor Target Pulse | Rear air mix damper servo sub-assembly target pulse | 128 to 384 |
·
MAX COLD: 254 (pulse)
·
MAX HOT: 299 (pulse) |
Rear air mix damper servo sub-assembly circuit malfunction |
| Rear Left Air Mix Damper Control Servo Motor Actual Pulse | Rear air mix damper servo sub-assembly actual pulse | 128 to 384 |
·
MAX COLD: 254 (pulse)
·
MAX HOT: 299 (pulse) |
Rear air mix damper servo sub-assembly circuit malfunction |
| Rear Right Air Mix Damper Control Servo Motor Target Pulse | No. 2 rear air mix damper servo sub-assembly target pulse | 128 to 384 |
·
MAX COLD: 258 (pulse)
·
MAX HOT: 213 (pulse) |
No. 2 rear air mix damper servo sub-assembly circuit malfunction |
| Rear Right Air Mix Damper Control Servo Motor Actual Pulse | No. 2 rear air mix damper servo sub-assembly actual pulse | 128 to 384 |
·
MAX COLD: 258 (pulse)
·
MAX HOT: 213 (pulse) |
No. 2 rear air mix damper servo sub-assembly circuit malfunction |
| Front Air Outlet Damper Control Servo Motor Target Pulse | - | - | - | Not applicated |
| Front Air Outlet Damper Control Servo Motor Actual Pulse | - | - | - | Not applicated |
| Front Control Rear Air Mix Damper Control Servo Motor Target Pulse | - | - | - | Not applicated |
| Front Control Rear Air Mix Damper Control Servo Motor Actual Pulse | - | - | - | Not applicated |
| Front Control Rear Air Outlet Damper Control Servo Motor Target Pulse | No. 3 air conditioning radiator damper servo sub-assembly target pulse | 128 to 384 |
·
FACE1: 249 (pulse)
·
FACE2: 250 (pulse)
·
FACE: 249 (pulse)
·
B/L: 266 (pulse)
·
FOOT: 273 (pulse)
·
F/D: 274 (pulse)
·
SHUT: 289 (pulse) |
No. 3 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Front Control Rear Air Outlet Damper Control Servo Motor Actual Pulse | No. 3 air conditioning radiator damper servo sub-assembly actual pulse | 128 to 384 |
·
FACE1: 249 (pulse)
·
FACE2: 250 (pulse)
·
FACE: 249 (pulse)
·
B/L: 266 (pulse)
·
FOOT: 273 (pulse)
·
F/D: 274 (pulse)
·
SHUT: 289 (pulse) |
No. 3 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Rear Air Outlet Damper Control Servo Motor Target Pulse | Rear mode damper servo sub-assembly target pulse | 128 to 384 |
·
FACE: 276 (pulse)
·
B/L: 225 (pulse)
·
FOOT: 200 (pulse) |
Rear mode damper servo sub-assembly circuit malfunction |
| Rear Air Outlet Damper Control Servo Motor Actual Pulse | Rear mode damper servo sub-assembly actual pulse | 128 to 384 |
·
FACE: 276 (pulse)
·
B/L: 225 (pulse)
·
FOOT: 200 (pulse) |
Rear mode damper servo sub-assembly circuit malfunction |
| PTC Request Count | Number of quick heater assembly elements requested to be driven | Min.: 0 Max.: 3 |
Number of quick heater assembly elements requested to be driven | PTC heater circuit malfunction (w/ PTC Heater) |
| PTC Actual Driving Count | Number quick heater assembly elements actually driven | Min.: 0 Max.: 3 |
Number quick heater assembly elements actually driven | PTC heater circuit malfunction (w/ PTC Heater) |
| Refrigerant Gas Type | Refrigerant gas type | R134a / Hfo1234yf | Refrigerant gas type displayed | - |
| PTC Driving Maximum Level | Maximum number of quick heater assembly elements that can be driven | Min.: 0 Max.: 3 |
Maximum number of quick heater assembly elements that can be driven | PTC heater circuit malfunction (w/ PTC Heater) |
| Refrigerant High Pressure History Count | Refrigerant high pressure history | 0 to 255 | Number of times refrigerant high pressure history stored displayed | *1 |
| Refrigerant Low Pressure History Count | Refrigerant low pressure history | 0 to 255 | Number of times refrigerant low pressure history stored displayed | *1 |
| Operation Limit Control History Count | History of auxiliary battery voltage drop in the past | 0 to 255 | Number of times auxiliary battery voltage dropped in the past displayed | Counted when the voltage drops below the specified level due to over discharge while driving.
|
| Efficient Ventilation Mode | Function to automatically change ambient air induction and room circulation is set | OFF / ON | Customized value displayed | - |
| Foot/DEF Automatic Blow Up Function | When air outlet was chosen in DEF (defroster), function to automatically increase air capacity is changed | OFF / ON | Customized value displayed | - |
| Foot/DEF Auto Mode | Function to turn the air flow from Foot/DEF ON automatically when AUTO MODE is ON | OFF / ON | Customized value displayed | - |
| ECO Mode Control | This function switches ON/OFF of the controlling function of the air conditioning by ECO mode. If there is no ECO MODE switch, this customize function is not available | OFF / ON | Customized value displayed | - |
| Fan Speed Increment Control | This function is defining how fast the A/C blower goes to the target air capacity when first activating the A/C | Short / Normal / Long | Customized value displayed | - |
| Outside Air Mode Auto Switch Function | This function switches ON/OFF of the function to switch the suction opening to the outside air mode automatically at the time of the ignition switch off | OFF / ON | Customized value displayed | - |
| A/C Auto Switch Mode | Function to turn the A/C ON automatically by pressing the AUTO button when the blower is ON and the A/C is OFF | OFF / ON | Customized value displayed | - |
| Ion Generate Control | Function to generate the ion is stopped when item is OFF | OFF / ON | Customized value displayed | - |
| Ambient Temperature Adjustment | Function to control with the shifted ambient temperature against the display ambient temperature | -3C / -2C / -1C / Normal / +1C / +2C / +3C | Customized value displayed | - |
| Set Temperature Shift | Function to control with the shifted temperature against the display temperature | -2C / -1C / Normal / +1C / +2C | Customized value displayed | - |
| Refrigerant Shortage Check | Function to cancel the refrigerant shortage check when item is OFF (The verification mode is excluded) | OFF / ON | Customized value displayed | - |
| Blower Level | Blower motor speed level | 0 to 31 | Displayed speed level increases in range between 0 and 31 as blower motor speed increases | Blower motor with fan sub-assembly circuit malfunction |
| Rear Blower Level | Blower motor speed level | 0 to 31 | Displayed speed level increases in range between 0 and 31 as blower motor speed increases | Rear blower motor with fan sub-assembly circuit malfunction (w/ Rear Air Conditioning System) |
| PTC Heater | Quick heater assembly drive status | Min.: 0 Max.: 3 |
Quick heater assembly drive status | PTC heater circuit malfunction (w/ PTC Heater) |
| A/C Driving Demand | A/C control cutoff signal | OFF / ON | The ECM sends the air conditioning control cutoff signal displayed | - |
| Ion Generator | Function to generate the ion is stopped when item is OFF | OFF / ON | Customized value displayed | Although this item is displayed on the GTS, it is not applicable to the air conditioning system. (w/ Ion Generator) |
*1: Refer to the following procedure to clear the refrigerant pressure history.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM>UTILITY
*2: Refer to the following procedure to clear the A/C operation limitation history.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM>UTILITY
Engine
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Coolant Temperature | Engine coolant temperature | Min.: -40°C (-40°F) Max.: 140°C (284°F) |
75 to 100°C (167 to 212°F): After warming up | This is the engine coolant temperature.
|
Power Integration No.1
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Magnetic Clutch Input Signal | Magnet clutch assembly input signal | OFF / ON | OFF: Magnet clutch assembly signal not input ON: Magnet clutch assembly signal input |
- |
| Magnetic Clutch Output Signal | Magnet clutch assembly output signal | OFF / ON | OFF: Magnet clutch assembly off ON: Magnet clutch assembly on |
- |
| Magnetic Clutch Output Current | Magnet clutch assembly circuit current | 0 to 255.0 | Below 0.7 A | - |
| Magnetic Clutch Fuse Shut Off Status | Magnetic clutch assembly fuse shut off status | OFF / ON | OFF: Fuse has no shut off history ON: Fuse has shut off history |
- |
| Magnetic Clutch Fuse Shut Off Count | Magnetic clutch assembly fuse shut off history | 0 to 255 | 0 | - |
| A/C Water Pump Input Signal | Heater accessory assembly input signal | OFF / ON | OFF: Heater accessory assembly signal not input ON: Heater accessory assembly signal input |
w/ Stop and Start System |
| A/C Water Pump Output Signal | Heater accessory assembly output signal | OFF / ON | OFF: Heater accessory assembly off ON: Heater accessory assembly on |
w/ Stop and Start System |
| A/C Water Pump Output Current | Heater accessory assembly circuit current | 0 to 255.0 | Below 0.7 A | w/ Stop and Start System |
| A/C Water Pump Fuse Shut Off Status | Heater accessory assembly fuse shut off status | OFF / ON | OFF: Fuse has no shut off history ON: Fuse has shut off history |
w/ Stop and Start System |
| A/C Water Pump Fuse Shut Off Count | Heater accessory assembly fuse shut off history | 0 to 255 | 0 | w/ Stop and Start System |
ACTIVE TEST
Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Air Conditioner
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Blower Level | Blower motor with fan sub-assembly operation | Min.: 0 Max.: 31 |
- |
| Rear Blower Level | Rear blower motor with fan sub-assembly operation | Min.: 0 Max.: 31 |
w/ Rear Cooler, w/ Rear Air Conditioning System |
| PTC Heater | Quick heater assembly operation | Min.: 0 Max.: 3 |
w/ PTC Heater |
| A/C Driving Demand | Air conditioning system operation | OFF / ON | Operate with the ignition switch ON (Engine running) and the vehicle stopped. |
| Rear A/C Magnet Valve | Rear air conditioning magnetic valve operation | OFF / ON | w/ Rear Cooler, w/ Rear Air Conditioning System |
| Ion Generator | Ion generator sub-assembly operation | OFF / ON | w/ Ion Generator |
| Front Left Air Mix Damper Control Servo Motor | No. 2 air conditioning radiator damper servo sub-assembly operation | Min: 128 Max: 384 |
Operates between 254 to 326 |
| FL Air Mix Cool Damper Control Servo Motor | No. 2 air conditioning radiator damper servo sub-assembly operation | Min: 128 Max: 384 |
for Dual:
Operates between 154 to 258
for 4 Zone:
Operates between 254 to 358 |
| Front Right Air Mix Damper Control Servo Motor | No. 4 air conditioning radiator damper servo sub-assembly operation | Min: 128 Max: 384 |
Operates between 186 to 258 |
| FR Air Mix Cool Damper Control Servo Motor | No. 4 air conditioning radiator damper servo sub-assembly | Min: 128 Max: 384 |
Operates between 154 to 258 |
| Front Left Air Outlet Damper Control Servo Motor | No. 1 air conditioning radiator damper servo sub-assembly operation | Min: 128 Max: 384 |
Operates between 258 to 364 |
| Front Right Air Outlet Damper Control Servo Motor | No. 6 air conditioning radiator damper servo sub-assembly operation | Min: 128 Max: 384 |
Operates between 148 to 254 |
| Air Inlet Damper Control Servo Motor | No. 1 blower damper servo sub-assembly operation | Min: 128 Max: 384 |
for LHD (Single Layer):
Operates between 238 to 258
for LHD (Double Layer):
Operates between 258 to 290
for RHD:
Operates between 222 to 254 |
| Front DEF Air Outlet Damper Control Servo Motor | No. 5 air conditioning radiator damper servo sub-assembly operation | Min: 128 Max: 384 |
Operates between 242 to 348 |
| FL FOOT/DEF Air Outlet Damper Control Servo Motor | No. 1 air conditioning radiator damper servo sub-assembly operation | Min: 128 Max: 384 |
Operates between 258 to 365 |
| FR FOOT/DEF Air Outlet Damper Control Servo Motor | No. 6 air conditioning radiator damper servo sub-assembly operation | Min: 128 Max: 384 |
Operates between 147 to 254 |
| Fr Control RL Air Mix Damper Control Servo Motor | No. 2 air conditioning radiator damper servo sub-assembly operation | Min: 128 Max: 384 |
Operates between 154 to 258 |
| Fr Control RR Air Mix Damper Control Servo Motor | No. 4 air conditioning radiator damper servo sub-assembly operation | Min: 128 Max: 384 |
Operates between 154 to 258 |
| Rear Left Air Mix Damper Control Servo Motor | Rear air mix damper servo sub-assembly operation | Min: 128 Max: 384 |
Operates between 254 to 299 |
| Rear Right Air Mix Damper Control Servo Motor | No. 2 rear air mix damper servo sub-assembly operation | Min: 128 Max: 384 |
Operates between 213 to 258 |
| Front Air Outlet Damper Control Servo Motor | - | - | Not applicated |
| Fr Control Rear Air Mix Damper Control Servo Motor | - | - | Not applicated |
| Fr Control Rear Air Outlet Damper Servo Motor | No. 3 air conditioning radiator damper servo sub-assembly operation | Min: 128 Max: 384 |
Operates between 249 to 289 |
| Rear Air Outlet Damper Control Servo Motor | Rear mode damper servo sub-assembly operation | Min: 128 Max: 384 |
Operates between 200 to 276 |
Engine
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Control the Engine Cooling Fan Duty Ratio | Control the cooling fan | 0 to 100% | Perform this test when the vehicle is stopped. |