HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  B142A88  Servo Motor LIN Communication Bus off  


DESCRIPTION

The air conditioning harness assembly connects the air conditioning amplifier assembly and the servo motors. The air conditioning amplifier assembly supplies power and sends operation instructions to each servo motor through the air conditioning harness assembly. Each servo motor sends damper position information to the air conditioning amplifier assembly.

DTC No. Detection Item DTC Detection Condition Trouble Area Memory DTC Output from Priority
B142A88 Servo Motor LIN Communication Bus off Diagnosis Condition:

Ignition switch ON


Malfunction Status:

Error or lost communication with each servo motor


Detection Time:

Continuously for 10 seconds or more


·

Air conditioning harness assembly

·

No. 1 air conditioning radiator damper servo sub-assembly

·

No. 2 air conditioning radiator damper servo sub-assembly

·

No. 3 air conditioning radiator damper servo sub-assembly

·

No. 4 air conditioning radiator damper servo sub-assembly

·

No. 5 air conditioning radiator damper servo sub-assembly

·

No. 6 air conditioning radiator damper servo sub-assembly (for 4 Zone)

·

No. 1 blower damper servo sub-assembly

·

Air conditioning amplifier assembly


Memorized Air Conditioner A

DTC Detection Condition Combination Table
Vehicle Condition
Pattern 1 Pattern 2
Diagnosis Condition Ignition switch ON ○ ○
Malfunction Status Error communication with each servo motor ○ -
Lost communication with each servo motor - ○
Detection Time Continuously for 10 seconds or more Continuously for 10 seconds or more
Trip Count 1 trip 1 trip

HINT:

If the conditions of either of these patterns are detected, a DTC will be stored.


WIRING DIAGRAM

E394969E04
5.281,1.813 5.74,2.01 0.458,0.198 10 false z16 5.281,1.958 6.885,2.375 1.604,0.417 10 false Air Conditioning Amplifier Assembly 4.563,4.063 6.979,4.479 2.417,0.417 10 false No. 3 Air Conditioning Radiator Damper Servo Sub-assembly 5.167,0.448 5.625,0.646 0.458,0.198 10 false BUS 5.167,0.76 5.625,0.958 0.458,0.198 10 false BBUS 5.167,1.063 5.625,1.26 0.458,0.198 10 false BUSG 6.156,0.573 6.615,0.771 0.458,0.198 10 false IC 6.542,0.594 7,0.792 0.458,0.198 10 false +B 4.938,0.406 5.396,0.604 0.458,0.198 10 false 3 4.938,0.76 5.396,0.958 0.458,0.198 10 false 4 4.938,1.073 5.396,1.271 0.458,0.198 10 false 2 4.792,7.802 6.51,8.229 1.719,0.427 10 false No. 1 Blower Damper Servo Sub-assembly 0.042,0.625 2.427,1.156 2.385,0.531 10 false No. 1 Air Conditioning Radiator Damper Servo Sub-assembly 0.031,2.01 2.448,2.583 2.417,0.573 10 false No. 1 Air Conditioning Radiator Damper Servo Sub-assembly 0.042,3.313 2.458,3.885 2.417,0.573 10 false No. 6 Air Conditioning Radiator Damper Servo Sub-assembly* 0.021,4.5 2.458,5.083 2.438,0.583 10 false No. 6 Air Conditioning Radiator Damper Servo Sub-assembly* 0.042,5.677 2.479,6.229 2.438,0.552 10 false No. 2 Air Conditioning Radiator Damper Servo Sub-assembly 0.042,7 2.49,7.469 2.448,0.469 10 false No. 2 Air Conditioning Radiator Damper Servo Sub-assembly 0.031,8.24 2.438,8.719 2.406,0.479 10 false No. 2 Air Conditioning Radiator Damper Servo Sub-assembly* 3.344,9.135 5.625,9.396 2.281,0.26 10 false Air Conditioning Harness Assembly 0.75,9.573 2.771,9.802 2.021,0.229 10 false : LIN Communication Line 0.125,9.188 2.146,9.417 2.021,0.229 10 false *: for 4 Zone

E459617E01
0.458,0.688 2.365,1.104 1.906,0.417 10 false No. 4 Air Conditioning Radiator Damper Servo Sub-assembly 0.469,1.885 2.375,2.302 1.906,0.417 10 false No. 4 Air Conditioning Radiator Damper Servo Sub-assembly 0.469,3.198 2.375,3.615 1.906,0.417 10 false No. 4 Air Conditioning Radiator Damper Servo Sub-assembly* 0.458,4.542 2.365,4.958 1.906,0.417 10 false No. 5 Air Conditioning Radiator Damper Servo Sub-assembly 0.458,5.906 2.365,6.323 1.906,0.417 10 false No. 5 Air Conditioning Radiator Damper Servo Sub-assembly 3.292,6.667 5.594,6.906 2.302,0.24 10 false Air Conditioning Harness Assembly 0.75,7.552 3.052,7.792 2.302,0.24 10 false : LIN Communication Line 0.146,7.177 2.448,7.417 2.302,0.24 10 false *: for 4 Zone

CAUTION / NOTICE / HINT

NOTICE:

This DTC is also output when servo motor initialization has failed. When servo motor initialization has failed, repair any malfunctions and perform servo motor initialization again.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM>INITIALIZATION


PROCEDURE

1.PERFORM ACTIVE TEST USING GTS
a.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Front Left Air Mix Damper Control Servo Motor No. 2 air conditioning radiator damper servo sub-assembly operation Min.: 128
Max.: 384
Operates between 254 to 326
FL Air Mix Cool Damper Control Servo Motor No. 2 air conditioning radiator damper servo sub-assembly operation Min.: 128
Max.: 384
for Dual:

Operates between 154 to 258


for 4 Zone:

Operates between 254 to 358


Front Right Air Mix Damper Control Servo Motor No. 4 air conditioning radiator damper servo sub-assembly operation Min.: 128
Max.: 384
Operates between 186 to 258
FR Air Mix Cool Damper Control Servo Motor No. 4 air conditioning radiator damper servo sub-assembly operation Min.: 128
Max.: 384
Operates between 154 to 258
Front Left Air Outlet Damper Control Servo Motor No. 1 air conditioning radiator damper servo sub-assembly operation Min.: 128
Max.: 384
Operates between 258 to 364
Front Right Air Outlet Damper Control Servo Motor No. 6 air conditioning radiator damper servo sub-assembly operation Min.: 128
Max.: 384
Operates between 148 to 254
Air Inlet Damper Control Servo Motor No. 1 blower damper servo sub-assembly operation Min.: 128
Max.: 384
for LHD (Single Layer):

Operates between 238 to 258


for LHD (Double Layer):

Operates between 258 to 290


for RHD:

Operates between 222 to 254


Front DEF Air Outlet Damper Control Servo Motor No. 5 air conditioning radiator damper servo sub-assembly operation Min.: 128
Max.: 384
Operates between 242 to 348
FL FOOT/DEF Air Outlet Damper Control Servo Motor No. 1 air conditioning radiator damper servo sub-assembly operation Min.: 128
Max.: 384
Operates between 258 to 365
FR FOOT/DEF Air Outlet Damper Control Servo Motor No. 6 air conditioning radiator damper servo sub-assembly operation Min.: 128
Max.: 384
Operates between 147 to 254
Fr Control RL Air Mix Damper Control Servo Motor No. 2 air conditioning radiator damper servo sub-assembly operation Min.: 128
Max.: 384
Operates between 154 to 258
Fr Control RR Air Mix Damper Control Servo Motor No. 4 air conditioning radiator damper servo sub-assembly operation Min.: 128
Max.: 384
Operates between 154 to 258
Fr Control Rear Air Outlet Damper Servo Motor No. 3 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 384
Operates between 249 to 289
Body Electrical > Air Conditioner > Active Test
Tester Display
Front Left Air Mix Damper Control Servo Motor
50004 450 26
Body Electrical > Air Conditioner > Active Test
Tester Display
FL Air Mix Cool Damper Control Servo Motor
50004 450 27
Body Electrical > Air Conditioner > Active Test
Tester Display
Front Right Air Mix Damper Control Servo Motor
50004 450 28
Body Electrical > Air Conditioner > Active Test
Tester Display
FR Air Mix Cool Damper Control Servo Motor
50004 450 29
Body Electrical > Air Conditioner > Active Test
Tester Display
Front Left Air Outlet Damper Control Servo Motor
50004 450 30
Body Electrical > Air Conditioner > Active Test
Tester Display
Front Right Air Outlet Damper Control Servo Motor
50004 450 31
Body Electrical > Air Conditioner > Active Test
Tester Display
Air Inlet Damper Control Servo Motor
50004 450 32
Body Electrical > Air Conditioner > Active Test
Tester Display
Front DEF Air Outlet Damper Control Servo Motor
50004 450 33
Body Electrical > Air Conditioner > Active Test
Tester Display
FL FOOT/DEF Air Outlet Damper Control Servo Motor
50004 450 34
Body Electrical > Air Conditioner > Active Test
Tester Display
FR FOOT/DEF Air Outlet Damper Control Servo Motor
50004 450 35
Body Electrical > Air Conditioner > Active Test
Tester Display
Fr Control RL Air Mix Damper Control Servo Motor
50004 450 36
Body Electrical > Air Conditioner > Active Test
Tester Display
Fr Control RR Air Mix Damper Control Servo Motor
50004 450 37
Body Electrical > Air Conditioner > Active Test
Tester Display
Fr Control Rear Air Outlet Damper Servo Motor
50004 450 49

Result:
Result Proceed to
All of the damper servo motors do not operate A
Any of the damper servo motors does not operate B
All of the damper servo motors operate C



A

2.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY

B

C

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

2.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY
NOTICE:

When inspecting the air conditioning amplifier assembly, do not bring the tester probes too close to each other as a short circuit may occur.


Pre-procedure1

a.
E407116C09
2.344,1.792 2.844,2.042 0.5,0.25 1.865,0.698 1.969,0.104 1.969,0.104 2.219,0.104 true 1.99,0.708 2.375,0.292 2.375,0.292 2.625,0.292 true 1.729,0.688 1.479,0.271 1.479,0.271 1.198,0.271 true 0.094,0.052 0.406,0.25 0.313,0.198 10 false *a 2.438,1.823 2.75,2.021 0.313,0.198 10 false z16 2.292,0.021 2.604,0.219 0.313,0.198 10 false BUS 2.677,0.208 3.208,0.417 0.531,0.208 10 false BUSG 0.396,3.938 0.927,4.146 0.531,0.208 10 false GND 0.75,0.188 1.281,0.396 0.531,0.208 10 false BBUS
*a Component without harness connected
(Air Conditioning Amplifier Assembly)


Disconnect the z16 air conditioning amplifier assembly connector.


Procedure1

b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
2 (BUSG) - Body ground Always Below 1 Ω



c.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
4 (BBUS) - Body ground Always 11 to 14 V



d.

Using an oscilloscope, check the waveform.

Tester Connection Tool Setting Switch Condition
3 (BUS) - 2 (BUSG) 2 V/DIV., 2 ms./DIV. Ignition switch ON

OK:

Waveform is similar to that shown in the illustration.


Result:
Proceed to
OK
NG



Post-procedure1

e.

None



OK

NG

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY