The air conditioning harness assembly connects the air conditioning amplifier assembly and the servo motors. The air conditioning amplifier assembly supplies power and sends operation instructions to each servo motor through the air conditioning harness assembly. Each servo motor sends damper position information to the air conditioning amplifier assembly.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| B142A88 | Servo Motor LIN Communication Bus off | Diagnosis Condition: Ignition switch ON Malfunction Status: Error or lost communication with each servo motor Detection Time: Continuously for 10 seconds or more |
·
Air conditioning harness assembly
·
No. 1 air conditioning radiator damper servo sub-assembly
·
No. 2 air conditioning radiator damper servo sub-assembly
·
No. 3 air conditioning radiator damper servo sub-assembly
·
No. 4 air conditioning radiator damper servo sub-assembly
·
No. 5 air conditioning radiator damper servo sub-assembly
·
No. 6 air conditioning radiator damper servo sub-assembly (for 4 Zone)
·
No. 1 blower damper servo sub-assembly
·
Air conditioning amplifier assembly |
Memorized | Air Conditioner | A |
| Vehicle Condition | |||
|---|---|---|---|
| Pattern 1 | Pattern 2 | ||
| Diagnosis Condition | Ignition switch ON | ○ | ○ |
| Malfunction Status | Error communication with each servo motor | ○ | - |
| Lost communication with each servo motor | - | ○ | |
| Detection Time | Continuously for 10 seconds or more | Continuously for 10 seconds or more | |
| Trip Count | 1 trip | 1 trip | |
If the conditions of either of these patterns are detected, a DTC will be stored.
This DTC is also output when servo motor initialization has failed. When servo motor initialization has failed, repair any malfunctions and perform servo motor initialization again.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM>INITIALIZATION
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Front Left Air Mix Damper Control Servo Motor | No. 2 air conditioning radiator damper servo sub-assembly operation | Min.: 128 Max.: 384 |
Operates between 254 to 326 |
| FL Air Mix Cool Damper Control Servo Motor | No. 2 air conditioning radiator damper servo sub-assembly operation | Min.: 128 Max.: 384 |
for Dual:
Operates between 154 to 258
for 4 Zone:
Operates between 254 to 358 |
| Front Right Air Mix Damper Control Servo Motor | No. 4 air conditioning radiator damper servo sub-assembly operation | Min.: 128 Max.: 384 |
Operates between 186 to 258 |
| FR Air Mix Cool Damper Control Servo Motor | No. 4 air conditioning radiator damper servo sub-assembly operation | Min.: 128 Max.: 384 |
Operates between 154 to 258 |
| Front Left Air Outlet Damper Control Servo Motor | No. 1 air conditioning radiator damper servo sub-assembly operation | Min.: 128 Max.: 384 |
Operates between 258 to 364 |
| Front Right Air Outlet Damper Control Servo Motor | No. 6 air conditioning radiator damper servo sub-assembly operation | Min.: 128 Max.: 384 |
Operates between 148 to 254 |
| Air Inlet Damper Control Servo Motor | No. 1 blower damper servo sub-assembly operation | Min.: 128 Max.: 384 |
for LHD (Single Layer):
Operates between 238 to 258
for LHD (Double Layer):
Operates between 258 to 290
for RHD:
Operates between 222 to 254 |
| Front DEF Air Outlet Damper Control Servo Motor | No. 5 air conditioning radiator damper servo sub-assembly operation | Min.: 128 Max.: 384 |
Operates between 242 to 348 |
| FL FOOT/DEF Air Outlet Damper Control Servo Motor | No. 1 air conditioning radiator damper servo sub-assembly operation | Min.: 128 Max.: 384 |
Operates between 258 to 365 |
| FR FOOT/DEF Air Outlet Damper Control Servo Motor | No. 6 air conditioning radiator damper servo sub-assembly operation | Min.: 128 Max.: 384 |
Operates between 147 to 254 |
| Fr Control RL Air Mix Damper Control Servo Motor | No. 2 air conditioning radiator damper servo sub-assembly operation | Min.: 128 Max.: 384 |
Operates between 154 to 258 |
| Fr Control RR Air Mix Damper Control Servo Motor | No. 4 air conditioning radiator damper servo sub-assembly operation | Min.: 128 Max.: 384 |
Operates between 154 to 258 |
| Fr Control Rear Air Outlet Damper Servo Motor | No. 3 air conditioning radiator damper servo sub-assembly pulse | Min.: 128 Max.: 384 |
Operates between 249 to 289 |
| Tester Display |
|---|
| Front Left Air Mix Damper Control Servo Motor |
| Tester Display |
|---|
| FL Air Mix Cool Damper Control Servo Motor |
| Tester Display |
|---|
| Front Right Air Mix Damper Control Servo Motor |
| Tester Display |
|---|
| FR Air Mix Cool Damper Control Servo Motor |
| Tester Display |
|---|
| Front Left Air Outlet Damper Control Servo Motor |
| Tester Display |
|---|
| Front Right Air Outlet Damper Control Servo Motor |
| Tester Display |
|---|
| Air Inlet Damper Control Servo Motor |
| Tester Display |
|---|
| Front DEF Air Outlet Damper Control Servo Motor |
| Tester Display |
|---|
| FL FOOT/DEF Air Outlet Damper Control Servo Motor |
| Tester Display |
|---|
| FR FOOT/DEF Air Outlet Damper Control Servo Motor |
| Tester Display |
|---|
| Fr Control RL Air Mix Damper Control Servo Motor |
| Tester Display |
|---|
| Fr Control RR Air Mix Damper Control Servo Motor |
| Tester Display |
|---|
| Fr Control Rear Air Outlet Damper Servo Motor |
| Result | Proceed to |
|---|---|
| All of the damper servo motors do not operate | A |
| Any of the damper servo motors does not operate | B |
| All of the damper servo motors operate | C |
A
B
C
When inspecting the air conditioning amplifier assembly, do not bring the tester probes too close to each other as a short circuit may occur.
Pre-procedure1
| *a | Component without harness connected (Air Conditioning Amplifier Assembly) |
Disconnect the z16 air conditioning amplifier assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2 (BUSG) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 4 (BBUS) - Body ground | Always | 11 to 14 V |
Using an oscilloscope, check the waveform.
| Tester Connection | Tool Setting | Switch Condition |
|---|---|---|
| 3 (BUS) - 2 (BUSG) | 2 V/DIV., 2 ms./DIV. | Ignition switch ON |
Waveform is similar to that shown in the illustration.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG