Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM
RM38G0E _58 Vehicle Interior _100766 HEATING / AIR CONDITIONING _0467925 AIR CONDITIONING SYSTEM C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  P05347A  Refrigerant Gas Fluid Leak or Seal Failure  


DESCRIPTION

This DTC is stored if the amount of refrigerant in the air conditioning system is insufficient.

The air conditioning amplifier assembly receives the ambient temperature signal, refrigerant pressure signal, etc. from various sensors.

Based on these signals, the air conditioning amplifier assembly detects the amount of refrigerant.

The A/C switch indicator is turned off and the air conditioning system is stopped if the amount of refrigerant is insufficient.

DTC No. Detection Item DTC Detection Condition Trouble Area Memory DTC Output from Priority
P05347A Refrigerant Gas Fluid Leak or Seal Failure Diagnosis Condition:

Normal operation refrigerant amount check conditions are met.

The following condition is detected in the normal operation refrigerant shortage check


Malfunction Status:

Amount of refrigerant is judged to be insufficient by normal operation refrigerant amount check.

Amount of refrigerant is insufficient


Detection Time:

Air conditioning system operating time: 15 minutes or more


·

Refrigerant volume

·

Air conditioning pressure sensor

·

Harness or connector

·

Air conditioning amplifier assembly


Memorized Air Conditioner A

WIRING DIAGRAM

E316642E40
4.479,2.865 4.938,3.063 0.458,0.198 10 false I32 4.479,3.031 6.927,3.365 2.448,0.333 10 false Air Conditioning Amplifier Assembly 4.563,1.094 5.01,1.281 0.448,0.188 10 false S5-3 4.573,1.573 5.021,1.76 0.448,0.188 10 false PRE 4.563,2.031 5.01,2.219 0.448,0.188 10 false SG-4 4.229,1.094 4.677,1.281 0.448,0.188 10 false 11 4.292,1.573 4.74,1.76 0.448,0.188 10 false 6 4.24,2.042 4.688,2.229 0.448,0.188 10 false 15 1.99,1.083 2.438,1.271 0.448,0.188 10 false 3 2,1.573 2.448,1.76 0.448,0.188 10 false 2 2,2.042 2.448,2.229 0.448,0.188 10 false 1 1.656,1.563 2.104,1.75 0.448,0.188 10 false PR 1.74,1.083 2.188,1.271 0.448,0.188 10 false + 1.75,2.042 2.198,2.229 0.448,0.188 10 false - 0.375,2.563 0.833,2.76 0.458,0.198 10 false B22 0.375,2.708 2.823,3.042 2.448,0.333 10 false Air Conditioning Pressure Sensor 5.531,0.938 5.979,1.125 0.448,0.188 10 false 5 V 5.99,1.688 6.438,1.875 0.448,0.188 10 false AD

PROCEDURE

1.CHECK REFRIGERANT PRESSURE

Pre-procedure1

a.

Install a manifold gauge set.


b.

Prepare the vehicle according to the table below.

Measurement Condition:
Item Condition
Doors Fully open
A/C Switch On
Recirculation/fresh Control Switch Recirculation
Set Temperature MAX COLD
Blower Speed HI
Air Conditioning Air Inlet Temperature 25 to 35°C (77 to 95°F)


Procedure1

c.

Compare the values displayed in the Data List and on the manifold gauge.

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Regulator Pressure Sensor Air conditioning pressure sensor -32.768 to 32.767 MPaG Actual refrigerant pressure displayed
·

Refrigerant line (gas leak etc.)

·

Air conditioning pressure sensor circuit malfunction


Body Electrical > Air Conditioner > Data List
Tester Display
Regulator Pressure Sensor
50003 450 106
Result:
Result Proceed to
Data List value and manifold gauge set value do not match A
Data List value matches manifold gauge set value B



Post-procedure1

d.

None



A

2.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING PRESSURE SENSOR - POWER SOURCE)

B

2.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING PRESSURE SENSOR - POWER SOURCE)

Pre-procedure1

a.

Disconnect the B22 air conditioning pressure sensor connector.


Procedure1

b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition

Click Location & Routing(B22)Location & Routing

Click Connector(B22)Engine Compartment>Engine Room Main Wire / Lamp Wire / No. 2 Engine Room Wire / No. 2 Lamp Wire / No. 3 Engine Room Wire / No. 6 Engine Room Wire / Washer Wiring Assembly>Air Conditioning Pressure Sensor

B22-3 (+) - Body ground Ignition switch ON 4.75 to 5.25 V


Result:
Proceed to
OK
NG



Post-procedure1

c.

None



OK

3.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING PRESSURE SENSOR - BODY GROUND)

NG

7.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
3.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING PRESSURE SENSOR - BODY GROUND)

Pre-procedure1

a.

Disconnect the B22 air conditioning pressure sensor connector.


Procedure1

b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(B22)Location & Routing

Click Connector(B22)Engine Compartment>Engine Room Main Wire / Lamp Wire / No. 2 Engine Room Wire / No. 2 Lamp Wire / No. 3 Engine Room Wire / No. 6 Engine Room Wire / Washer Wiring Assembly>Air Conditioning Pressure Sensor

B22-1 (-) - Body ground Always Below 1 Ω


Result:
Proceed to
OK
NG



Post-procedure1

c.

None



OK

4.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)

NG

6.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
4.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)

Pre-procedure1

a.

Disconnect the B22 air conditioning pressure sensor connector.


b.

Disconnect the I32 air conditioning amplifier assembly connector.


Procedure1


Post-procedure1

d.

None



OK

5.INSPECT AIR CONDITIONING AMPLIFIER ASSEMBLY (SENSOR SIGNAL CIRCUIT)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

5.INSPECT AIR CONDITIONING AMPLIFIER ASSEMBLY (SENSOR SIGNAL CIRCUIT)
NOTICE:
·

If refrigerant pressure on the high pressure side becomes extremely high, the fail-safe function stops compressor operation.

·

It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the malfunction may recur after a while.



HINT:

When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to operation of the ambient temperature sensor (thermistor assembly) and the evaporator temperature sensor (No. 1 cooler thermistor) to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.


Pre-procedure1

a.

Connect the I32 air conditioning amplifier assembly connector.


b.

Connect the B22 air conditioning pressure sensor connector.


c.

Prepare the vehicle according to the table below.

Measurement Condition:
Item Condition
Doors Fully open
A/C Switch On
Recirculation/fresh Control Switch Recirculation
Set Temperature MAX COLD
Blower Speed HI
Air Conditioning Air Inlet Temperature 25 to 35°C (77 to 95°F)


Procedure1

d.

Measure the voltage according to the value(s) in the table below.

E445156C04
3.708,0.271 4.135,0.521 0.427,0.25 4.49,1.927 4.25,1.927 4.25,1.927 4.094,1.281 true 0.104,0.021 0.417,0.177 0.313,0.156 10 false *a 3.813,0.333 4.271,0.531 0.458,0.198 10 false I32 4.573,1.854 5.188,2.052 0.615,0.198 10 false PRE
*a Component with harness connected
(Air Conditioning Amplifier Assembly)
- -


Standard Voltage:
Tester Connection Condition Specified Condition

Click Location & Routing(I32)Location & Routing

Click Connector(I32)Instrument Panel>Instrument Panel Wire / Mobile Wireless Charger Cord / No. 1 Navigation Wire / No. 2 Instrument Panel Wire / No. 5 Instrument Panel Wire / Telephone Computer Wire>Air Conditioning Amplifier Assembly

I32-6 (PRE) - Body ground A/C switch on (When cooler compressor assembly running) 0.62 to 4.73 V*


*: Value when sensor power source voltage is 5 V



e.

Read the Data List according to the display on the GTS.

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Regulator Pressure Sensor Air conditioning pressure sensor -32.768 to 32.767 MPaG Actual refrigerant pressure displayed
·

Refrigerant line (gas leak etc.)

·

Air conditioning pressure sensor circuit malfunction


Body Electrical > Air Conditioner > Data List
Tester Display
Regulator Pressure Sensor
50003 450 106
OK:

The voltage and value displayed in the Data List change.


Result:
Result Proceed to
OK A
NG (The voltage changes but the value displayed in the Data List does not change.) B
NG (The voltage does not change.) C



Post-procedure1

f.

None



A

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

B

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

C

6.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)

Pre-procedure1

a.

Disconnect the B22 air conditioning pressure sensor connector.


b.

Disconnect the I32 air conditioning amplifier assembly connector.


Procedure1


Post-procedure1

d.

None



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

7.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)

Pre-procedure1

a.

Disconnect the B22 air conditioning pressure sensor connector.


b.

Disconnect the I32 air conditioning amplifier assembly connector.


Procedure1

c.

Post-procedure1

d.

None



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR