The blower motor with fan sub-assembly is operated by signals from the air conditioning amplifier assembly.
If the airflow volume is low or the blower speed cannot be changed, the following factors may be the cause.
| Symptom | Factor |
|---|---|
| Airflow volume cannot be changed |
·
Air conditioning amplifier assembly malfunction
·
Blower motor with fan sub-assembly malfunction
·
Harness or connector |
Inspect the fuses for circuits related to this system before performing the following procedure.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Blower Level | Blower motor with fan sub-assembly operation | Min.: 0 Max.: 31 |
- |
| Tester Display |
|---|
| Blower Level |
| Result | Proceed to |
|---|---|
| Blower motor with fan sub-assembly does not operate | A |
| Blower motor with fan sub-assembly operates but does not change speed | B |
A
B
Disconnect the I36 blower motor with fan sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(I36)Location & Routingewd_type=routing;type=c;code=I36 |
||
| I36-1 (GND) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(I36)Location & Routingewd_type=routing;type=c;code=I36 |
||
| I36-3 (+B) - Body ground | Always | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the I33 air conditioning amplifier assembly connector.
Disconnect the I36 blower motor with fan sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(I33,I36)Location & Routingewd_type=routing;type=c,c;code=I33,I36 |
||
| I33-21 (BLW) - I36-2 (SI) | Always | Below 1 Ω |
| I33-21 (BLW) or I36-2 (SI) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the I33 air conditioning amplifier assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(I33)Location & Routingewd_type=routing;type=c;code=I33 |
||
| I33-21 (BLW) - Body ground | Always | 4.75 to 5.25 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component with harness connected (Blower with Fan Motor Sub-assembly) |
Using an oscilloscope, check the waveform.
| Tester Connection | Tool Setting | Condition |
|---|---|---|
Click Location & Routing(I36)Location & Routingewd_type=routing;type=c;code=I36 |
||
| I36-2 (SI) - Body ground | 1 V/DIV., 500 μs./DIV. |
·
Ignition switch ON
·
Blower speed: LO |
The waveform varies with the blower speed.
Waveform is similar to that shown in the illustration.
| Proceed to |
|---|
| OK |
| NG |
OK
NG