If the cooling effect of the air conditioning system is weak, the following factors may be the cause.
| Symptom | Factor |
|---|---|
|
·
Cooling is poor.
·
Takes time to cool down. |
·
Customize setting
·
Cooler compressor assembly malfunction
·
Excessive refrigerant
·
Quantity of refrigerant gas lack
·
Dirty cooler condenser
·
Cooling fan system malfunction
·
A/M servo motor malfunction
·
Damper and link operation (jamming)
·
Automatic light control sensor malfunction
·
Warm air flow |
| Symptom | Factor |
|---|---|
|
·
Cooling is poor.
·
Takes time to cool down. |
·
Customize setting
·
Cooler compressor assembly malfunction
·
Excessive refrigerant
·
Quantity of refrigerant gas lack
·
Dirty cooler condenser
·
Cooling fan system malfunction
·
Warm air flow |
| Symptom | Factor |
|---|---|
|
·
Cooling is poor.
·
Takes time to cool down. |
·
Customize setting
·
Cooler compressor assembly malfunction
·
Excessive refrigerant
·
Quantity of refrigerant gas lack
·
Dirty cooler condenser
·
Cooling fan system malfunction
·
A/M servo motor malfunction
·
Damper and link operation (jamming)
·
Warm air flow |
Confirm that ECO HEAT/COOL switch is set to off.
Confirm that ECO drive mode is set to off.
When the ECO drive mode is set to ON, the air conditioning amplifier assembly performs minimal air conditioning control in order to promote the improvement of fuel economy. Ensure that the customer understands that the airflow volume will be decreased compared to normal operation.
| Control | Control Summary |
|---|---|
| Air Volume Control | Sets the blower level to less. |
| Proceed to |
|---|
| NEXT |
NEXT
Prepare the vehicle according to the table below.
| Item | Condition |
|---|---|
| Vehicle Condition | Engine running |
| A/C Switch | On |
| Ambient Temperature*1 | 0 to 49°C (32 to 120°F) |
| Air Conditioning Air Inlet Temperature*2 | 25 to 35°C (77 to 95°F) |
| Set Temperature | MAX COLD |
| Recirculation/fresh Control Switch | Recirculation |
| Air Vent Damper Position | FACE |
| Blower Speed | HI |
*1: This inspection can be judged correctly only if the ambient temperature is within a range of 0 to 49°C (32 to 120°F). Therefore, postpone the test if the temperature is low.
*2: This inspection can be judged correctly only if the air inlet temperature is within a range of 25 to 35°C (77 to 95°F). Therefore, postpone the test if the temperature is out of range.
Using the GTS, check the amount of refrigerant.
| Tester Display |
|---|
| Refrigerant Gas Volume Check |
If the conditions for the inspection are not met, "Refrigerant incorrect" will be displayed on the GTS. Confirm the conditions of the inspection and perform the check again.
If the amount of refrigerant is insufficient, "Refrigerant shortage" is displayed on the GTS and the indicator light on the A/C switch turns off.
When performing this inspection, a DTC will not be output even if "Refrigerant shortage" is displayed on the GTS.
| Result | Amount of Refrigerant |
|---|---|
| Refrigerant shortage | Insufficient or leakage |
| Refrigerant correct | Correct |
| Refrigerant incorrect | Incorrect |
"Refrigerant correct" is displayed on the GTS.
| Result | Proceed to |
|---|---|
| OK (for Front) | A |
| OK (for Rear (w/ Rear Cooler)) | B |
| OK (for Rear (w/ Rear Air Conditioning System)) | C |
| NG | D |
A
B
Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT (for HFC-134a(R134a))>ON-VEHICLE INSPECTION
C
D
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Front Left Air Mix Damper Control Servo Motor | No. 2 air conditioning radiator damper servo sub-assembly operation | 128: Min 384: Max |
Operates between 254 to 326 |
| FL Air Mix Cool Damper Control Servo Motor | No. 2 air conditioning radiator damper servo sub-assembly operation | 128: Min 384: Max |
for Dual:
Operates between 154 to 258
for 4 Zone:
Operates between 254 to 358 |
| Front Right Air Mix Damper Control Servo Motor | No. 4 air conditioning radiator damper servo sub-assembly operation | 128: Min 384: Max |
Operates between 186 to 258 |
| FR Air Mix Cool Damper Control Servo Motor | No. 4 air conditioning radiator damper servo sub-assembly operation | 128: Min 384: Max |
Operates between 154 to 258 |
| Fr Control RL Air Mix Damper Control Servo Motor | No. 2 air conditioning radiator damper servo sub-assembly operation | 128: Min 384: Max |
Operates between 154 to 258 |
| Fr Control RR Air Mix Damper Control Servo Motor | No. 4 air conditioning radiator damper servo sub-assembly operation | 128: Min 384: Max |
Operates between 154 to 258 |
| Tester Display |
|---|
| Front Left Air Mix Damper Control Servo Motor |
| Tester Display |
|---|
| FL Air Mix Cool Damper Control Servo Motor |
| Tester Display |
|---|
| Front Right Air Mix Damper Control Servo Motor |
| Tester Display |
|---|
| FR Air Mix Cool Damper Control Servo Motor |
| Tester Display |
|---|
| Fr Control RL Air Mix Damper Control Servo Motor |
| Tester Display |
|---|
| Fr Control RR Air Mix Damper Control Servo Motor |
Damper servo motor is operated.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
Disconnect the K4 automatic light control sensor connector.
Disconnect the I3 main body ECU (multiplex network body ECU) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(K4,I3)Location & Routingewd_type=routing;type=c,c;code=K4,I3 Click Connector(K4)Instrument Panel>No. 3 Instrument Panel Wire>Automatic Light Control Sensorewd_type=component;type=c;code=K4;pinno=1,2,4 |
||
| K4-1 (CLTB) - I3-8 (CLTB) | Always | Below 1 Ω |
| K4-2 (CLTE) - I3-21 (CLTE) | Always | Below 1 Ω |
| K4-4 (CLTS) - I3-20 (CLTS) | Always | Below 1 Ω |
| K4-1 (CLTB) or I3-8 (CLTB) - Other terminals and body ground | Always | 10 kΩ or higher |
| K4-2 (CLTE) or I3-21 (CLTE) - Other terminals and body ground | Always | 10 kΩ or higher |
| K4-4 (CLTS) or I3-20 (CLTS) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereVehicle Exterior>LIGHTING (EXT)>AUTOMATIC LIGHT CONTROL SENSOR>ON-VEHICLE INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT (for HFC-134a(R134a))>ON-VEHICLE INSPECTION
NG
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Rear Left Air Mix Damper Control Servo Motor | Rear air mix damper servo sub-assembly operation | Min.: 128 Max.: 384 |
Operates between 254 to 299 pulses |
| Rear Right Air Mix Damper Control Servo Motor | No. 2 rear air mix damper servo sub-assembly operation | Min.: 128 Max.: 384 |
Operates between 213 to 258 pulses |
| Rear Air Outlet Damper Control Servo Motor | Rear mode damper servo sub-assembly operation | Min.: 128 Max.: 384 |
Operates between 200 to 276 pulses |
| Tester Display |
|---|
| Rear Left Air Mix Damper Control Servo Motor |
| Tester Display |
|---|
| Rear Right Air Mix Damper Control Servo Motor |
| Tester Display |
|---|
| Rear Air Outlet Damper Control Servo Motor |
Damper servo motor is operated.
| Proceed to |
|---|
| OK |
| NG |
OK
Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT (for HFC-134a(R134a))>ON-VEHICLE INSPECTION
NG
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM>DIAGNOSTIC TROUBLE CODE CHART