This circuit detects the ignition switch ON or off condition, and sends it to the main body ECU (multiplex network body ECU).
Inspect the fuses for circuits related to this system before performing the following procedure.
Before replacing the main body ECU (multiplex network body ECU), refer to Service Bulletin.
Check for DTCs.
Entry and start system (for Start Function) DTCs are not output.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| IGR Power | Ignition switch ON signal | OFF or ON | OFF: Ignition switch off ON: Ignition switch ON |
- |
| Tester Display |
|---|
| IGR Power |
Normal conditions listed above are displayed.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the 5B, 5C and 5K power distribution box assembly connectors.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 5K-1 - Body ground | Always | 11 to 14 V |
| 5B-27 - Body ground | Ignition switch ON | 11 to 14 V |
| Ignition switch off | Below 1 V |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 5B-36 - Body ground | Always | Below 1 Ω |
| 5C-41 - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the power distribution box assembly.
for LHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for LHD)>REMOVAL
for RHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for RHD)>REMOVAL
| *a | Component without harness connected (Power Distribution Box Assembly) |
- | - |
Remove the main body ECU (multiplex network body ECU) from the power distribution box assembly.
for LHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for LHD)>REMOVAL
for RHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for RHD)>REMOVAL
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 5C-41 - MB-13 (GND1) | Always | Below 1 Ω |
| 5B-36 - MB-14 (GND2) | Always | Below 1 Ω |
| MB-27 (IGR) - 5K-1 | Battery not connected to 5B-27 and 5B-36 | 10 kΩ or higher |
| Battery positive (+) → 5B-27 Battery negative (-) → 5B-36 |
Below 1 Ω | |
| MB-13 (GND1) - 5B-36 | Always | Below 1 Ω |
| Result | Proceed to |
|---|---|
| OK (for LHD) | A |
| OK (for RHD) | B |
| NG (for LHD) | C |
| NG (for RHD) | D |
A
B
C
D