Refer to DTC P2AB711.
Click hereEngine / Hybrid System>V35A-FTS (ENGINE CONTROL)>SFI SYSTEM>P2AB711
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Note |
|---|---|---|---|---|---|
| P2AB715 | Wastegate Position Sensor "A" Circuit Short to Battery or Open | The ball valve position sensor (bank 1) output voltage is higher than 4.8 V for 3 seconds or more (1 trip detection logic). |
·
Open or short in waste gate position sensor (waste gate valve actuator assembly (bank 1)) circuit
·
Waste gate position sensor (waste gate valve actuator assembly (bank 1))
·
ECM |
- | SAE: P2AB9 |
| P2ABA15 | Wastegate Position Sensor "B" Circuit Short to Battery or Open | The ball valve position sensor (bank 2) output voltage is higher than 4.8 V for 3 seconds or more (1 trip detection logic). |
·
Open or short in waste gate position sensor (waste gate valve actuator assembly (bank 2)) circuit
·
Waste gate position sensor (waste gate valve actuator assembly (bank 2))
·
ECM |
- | SAE: P2ABC |
If the output voltage transmitted by the waste gate valve position sensor remains high, the ECM interprets this as a malfunction in the sensor circuit, stores a DTC.
| Frequency of Operation | Continuous |
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Start the engine and warm it up until the engine coolant temperature reaches 75°C (167°F) or higher.
Turn the ignition switch off and wait for at least 30 seconds.
Turn the ignition switch to ON.
Turn the GTS on.
Start the engine.
Idle the engine for 5 seconds or more.
Enter the following menus: Powertrain / Engine / Trouble Codes.
Read the DTCs.
If a pending DTC is output, the system is malfunctioning.
If a pending DTC is not output, perform the following procedure.
Enter the following menus: Powertrain / Engine / Utility / All Readiness.
Input the DTC: P2AB715 or P2ABA15.
Check the DTC judgment result.
| GTS Display | Description |
|---|---|
| NORMAL |
·
DTC judgment completed
·
System normal |
| ABNORMAL |
·
DTC judgment completed
·
System abnormal |
| INCOMPLETE |
·
DTC judgment not completed
·
Perform driving pattern after confirming DTC enabling conditions |
If the judgment result is NORMAL, the system is normal.
If the judgment result is ABNORMAL, the system is malfunctioning.
Refer to DTC P2AB711.
Click hereEngine / Hybrid System>V35A-FTS (ENGINE CONTROL)>SFI SYSTEM>P2AB711
Read Freeze Frame Data using the GTS. The ECM records vehicle and driving condition information as Freeze Frame Data the moment a DTC is stored. When troubleshooting, Freeze Frame Data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.
Bank 1 refers to the bank that includes the No. 1 cylinder*.
*: The No. 1 cylinder is the cylinder which is farthest from the transmission.
Bank 2 refers to the bank that does not include the No. 1 cylinder.
| DTC | Suspected Area |
|---|---|
| P2AB715 | Bank 1 |
| P2ABA15 | Bank 2 |
Make sure that the connector is properly connected. If it is not, securely connect it and check for DTCs again.
Disconnect the waste gate valve actuator assembly (turbocharger sub-assembly) connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(C45,C46)Location & Routingewd_type=routing;type=c,c;code=C45,C46 |
||
| C45-5 (VCWR) - Body ground | Ignition switch ON | 4.5 to 5.5 V |
| C46-5 (VCWL) - Body ground | Ignition switch ON | 4.5 to 5.5 V |
| C45-3 (AWGR) - Body ground | Ignition switch ON | 3.0 to 5.5 V |
| C46-3 (AWGL) - Body ground | Ignition switch ON | 3.0 to 5.5 V |
Turn the ignition switch off and wait for at least 30 seconds.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(C45,C46)Location & Routingewd_type=routing;type=c,c;code=C45,C46 |
||
| C45-5 (VCWR) - C45-3 (AWGR) | Ignition switch off | 190 to 210 kΩ |
| C46-5 (VCWL) - C46-3 (AWGL) | Ignition switch off | 190 to 210 kΩ |
| C45-4 (EWGR) - Body ground | Always | Below 1 Ω |
| C46-4 (EWGL) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Perform "Inspection After Repair" after replacing the turbocharger sub-assembly.
Click hereEngine / Hybrid System>V35A-FTS (ENGINE CONTROL)>SFI SYSTEM>INITIALIZATION
OK
NG
Disconnect the waste gate valve actuator assembly (turbocharger sub-assembly) connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(C45,C37,C46)Location & Routingewd_type=routing;type=c,c,c;code=C45,C37,C46 |
||
| C45-3 (AWGR) - C37-99 (WGA) | Always | Below 1 Ω |
| C45-4 (EWGR) - C37-106 (EWGA) | Always | Below 1 Ω |
| C46-3 (AWGL) - C37-98 (WGA2) | Always | Below 1 Ω |
| C46-4 (EWGL) - C37-104 (EWG2) | Always | Below 1 Ω |
| C45-4 (EWGR) or C37-106 (EWGA) - Body ground and other terminals | Always | 10 kΩ or higher |
| C46-4 (EWGL) or C37-104 (EWG2) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG