The No. 2 cooler thermistor is installed to the evaporator in the rear air conditioning unit to detect the temperature of the cooled air that has passed through the evaporator, which is used to control the air conditioning system. It sends signals to the air conditioning amplifier assembly. The resistance of the No. 2 cooler thermistor changes in accordance with the temperature of the cooled air that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage (5 V) to the No. 2 cooler thermistor and reads voltage changes as the resistance of the No. 2 cooler thermistor changes. This sensor is used for frost prevention.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P153B15 | Rear Evaporator Temperature Sensor Circuit Short to Battery or Open | Diagnosis Condition: Ignition switch ON Malfunction Status: Open or short (+B) in rear evaporator temperature sensor circuit Detection Time: Continuously for 4 seconds or more |
·
No. 2 cooler wiring harness sub-assembly
·
Air conditioning amplifier assembly |
Memorized | Air Conditioner | A |
| Vehicle Condition | |||
|---|---|---|---|
| Pattern 1 | Pattern 2 | ||
| Diagnosis Condition | Ignition switch ON | ○ | ○ |
| Malfunction Status | Open in evaporator temperature sensor circuit | ○ | - |
| Short (+B) in evaporator temperature sensor circuit | - | ○ | |
| Detection Time | Continuously for 4 seconds or more | Continuously for 4 seconds or more | |
| Trip Count | 1 trip | 1 trip | |
If the conditions of either of these patterns are detected, a DTC will be stored.
Pre-procedure1
Disconnect the Q10 No. 1 cooler wiring harness sub-assembly connector.
procedure1
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
Click Location & Routing(Q10)Location & Routingewd_type=routing;type=c;code=Q10 |
||
| Q10-8 (+) - Body ground | Ignition switch ON | 0 to 5.5 V |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the Q10 No. 2 cooler wiring harness sub-assembly connector.
Connect terminals 7 and 8 of the rear evaporator on the No. 2 cooler wiring harness sub-assembly side.
Procedure1
According to the display on the GTS, read the Data List.
| Tester Display |
|---|
| Rear Evaporator Temperature Sensor |
| GTS Display | Specified Condition |
|---|---|
| Rear Evaporator Temperature Sensor | 327.67°C (621.81°F) |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the Q10 No. 2 cooler wiring harness sub-assembly connector.
Disconnect the I30 air conditioning amplifier assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(Q10,I30)Location & Routingewd_type=routing;type=c,c;code=Q10,I30 |
||
| Q10-7 (-) - I30-15 (SG-9) | Always | Below 1 Ω |
| Q10-8 (+) - I30-11 (TEC) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the Q10 No. 2 cooler wiring harness sub-assembly connector.
Disconnect the I30 air conditioning amplifier assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(Q10,I30)Location & Routingewd_type=routing;type=c,c;code=Q10,I30 |
||
| Q10-8 (+) or I30-11 (TEC) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG